background image

Pre-installation

Installation

PumpWise guidelines

General specification

Trouble shooting

PumpWise and warranty

ISSUE 14   September 2011

Pump installation and 

warranty guide for pumps   

RGP, RHP, RSP and ESP

PERF

Salamander Pumped Shower Systems Limited

 

Unit 2c Colima A

venue, Sunderland, SR5 3XE

Tel:

 
0191 516 2002   

 

Fax:
 
0191 548 4445

 

Email:

 [email protected]

6479

W

arranty car

d

Please use block capitals:

User name

 

Address

 
Postcode 

 

Tel No
.

 
Email address

Installer name

 
Address

 
Postcode 

 

Tel No
.

 
Email address

Supplier fr

om whom pump was pur

chased

 

Name

 
Address

   

Postcode

W

hat is the appr

oximate cold water stor

age capacity (in gallons)?

Pump

 

serial 

 

number

Model

  

Date of 

 

pur
chase 

  _____

 /  _____

 / 

_____

W

her
e is the pump situated? How far is it fr

om the hot water cylinder?

6  

Does the pump have dedicated hot and cold water feeds (not shar

ed 

with other services)   

YES 

M

  

NO 

M

 Does the hot water cylinder have a flange fitted? If yes

, what type?

 

YES 

M

    NO 

M   

Type

 Does the hot water cylinder have a temper

atur
e contr

ol fitted? If yes

what temper

atur
e is the cylinder stat set to?

 

YES 

M

    NO 

M   

Temper

ature

11

 W

hy did you choose a Salamander pump?

 

Comments

I am inter

ested in an extended warr

anty
.

  

M

 Please tick box

 

Please send details of the Extended 

W

arr

anty Scheme

 

and application form.

SAL6479 Pumps Install DocAW1 .indd   1-1

29/09/2011   11:27

Summary of Contents for RGP

Page 1: ...Postcode 4 What is the approximate cold water storage capacity in gallons Pump serial number Model Date of purchase _____ _____ _____ 5 Where is the pump situated How far is it from the hot water cyli...

Page 2: ...l us implement our engineers recommendation for your installation situation then ask your customer to register When the job is finished tear off the final page of this instruction manual and hand it t...

Page 3: ...an air vent on the supply pipe work to a pump Where the pump is servicing two or more bathrooms the cold water supply to the cylinder must be in 28mm pipe work 2 2 Cold water storage Ensure that the c...

Page 4: ...pump must be connected to the electrical supply using the mains cable with the attached plug This plug must be connected to an accessible socket that has been installed in compliance with BS7671 I E E...

Page 5: ...per bathroom The hot connection must be via an approved side or top entry flange see page 16 Vent and other services Cold water storage MAX 65 C H C Outlet Inlet Outlet Inlet Fig 5 Right pump feeding...

Page 6: ...tive head Usable capacity minimum 50 gallons per bathroom The hot connection must be via an approved side or top entry flange see page 16 Vent and other services Cold water storage MAX 60 C H C Outlet...

Page 7: ...throom C Fig 10 ESP CPV single Tank fed pressurised cylinder or Combi boiler system with Right ESP CPV single pump to boost the hot supply water pressure and cold water mains supplies cold to shower b...

Page 8: ...of cold storage The typical recovery rate of a 1 2 inch high pressure part II BS1212 ball valve is 15PSI 1 0 bar 0 97 galls min 30PSI 2 0 bar 1 34 galls min 40PSI 2 7 bar 1 58 galls min 60PSI 4 0 bar...

Page 9: ...starvation protection pipework arrangements and stored hot water Fortic type tanks and pre assembled units Typically used in very small flats and houses Not usually with sufficient water capacity of...

Page 10: ...of the hot supply water to the pump The No Stop Essex flange is in all circumstances the best option S flange Complete with compression pump and open vent connections Also supplied with an adaptor to...

Page 11: ...is simply achieved by use of a cylinder thermostat and zone valve or direct acting thermostatic valve e g tapstat In systems where the stored hot water temperature is not controlled eg Aga solid fuel...

Page 12: ...V valve Is the temperature set to 65 C maximum Fault Probable cause Recommended solution Reduced intermittent flow Incorrect or no anti aeration flange fitted Check that installation complies with Sal...

Page 13: ...ment which shall in the opinion of the Company have proved defective by reason only of the Company s materials or workmanship providing always that the Company shall be under no obligation whatsoever...

Page 14: ...ion PumpWise guidelines General specification Trouble shooting PumpWise and warranty Freepost RLXE JHHY HLHJ Salamander Pumps Unit 2c Colima Avenue Sunderland SR5 3XE Notes SAL6479 Pumps Install DocAW...

Reviews: