Technical specifications - CT Force

General specifications – CT Xtra & CT Bathroom 

Applications

All Salamander pumps are designed to boost low pressure hot and cold supplies from  

cistern-fed services. When supplies from a water heater or a combination boiler are to be 

boosted contact the Salamander PumpWise helpline on 0191 516 2002 for guidance.

Voltage

230 volts, 50 Hz.

Motor type

Capacitor start and run induction type motor with stainless steel shaft and in-built resetting 

thermal protection (complies with BS5000 part 11).

Maximum head

All CT Xtra and CT Bathroom pumps are rated for a maximum static head of 10 metres.  

(100 kPa / 1.0 bar)

Anti-vibration couplers

Do not bend 

Please refer to the Technical Specifications table for information on which AV Couplers are 

supplied with each pump.

Mechanical seals

Rotary mechanical face seals are used. Scale deposits in water supplies can cause the 

mechanical seal to stick if left for long periods without use. The pump must be run for at least 

five minutes every four weeks to ‘exercise’ all working parts.

Connections

¾”

 BSP male.

Initiation

Only applies to positive head pumps. Fully automatic, flow operated, requiring 1 litre in 30 sec 

per side or 2 litres in 30 sec mixed. 

Temperature

Maximum fluid temperature 60ºC.

Pump noise

Salamander has engineered this product range to be as quiet as possible, however no pump 

is completely silent. Correct installation (anti-vibration couplers straight, rubber feet fitted) 

will minimise noise, vibration and transmission noise.

Standards and approvals

Splash proof rating IPX2; complies with the requirements of  

current British and European safety standards for household and 

similar electrical appliances; meets with Compliance with European 

Community Directives (CE). Due to continuous improvement and 

updating specifications may be altered without prior notice.
The CT Xtra and CT Bathroom ranges of pumps are also fully WRAS 

approved. CT Xtra has also been awarded Quiet Mark.

Part No.

Description

Specification

Performance

Connection Type

Pump Volumetrics

Packed Pump 

Volumetrics

Electrical 

Input

Pump 

Type

Pump

Hoses

Isolators

Dimensions

Dimensions

CT FORCE

Force 15PT
Force 15IPT

1.5 Bar Twin End
Positive Head Shower 

Pump

3A

110
(1.1)

130
(1.3)

150
(1.5)

¾”

22mm
21mm

4.96 180 120 160 6.02 298 218 205

Force 20PT
Force 20IPT

2.0 Bar Twin End
Positive Head Shower 

Pump

3A

150
(1.5)

180
(1.8)

200
(2.0)

¾”

22mm
21mm

4.97 180 120 160 6.03 298 218 205

Force 30PT
Force 30IPT

3.0 Bar Twin End
Positive Head Shower 

Pump

3A

220
(2.2)

260
(2.6)

300
(3.0)

¾”

22mm
21mm

6.22 210 120 160 7.34 298 218 205

Force 20PS
Force 20IPS

2.0 Bar Single End
Positive Head Shower 

Pump

3A

150
(1.5)

180
(1.8)

200
(2.0)

¾”

22mm
21mm

4.33 183 120 160 5.17 298 218 205

Force 30PS
Force 30IPS

3.0 Bar Single End
Positive Head Shower 

Pump

3A

210
(2.1)

260
(2.6)

300
(3.0)

¾”

22mm
21mm

5.61 213 120 160 6.48 298 218 205

CT FORCE Universal Pumps

Force 15TU
Force 15ITU

1.5 Bar Twin End
Positive and Negative 

Head Shower Pump

3A

110
(1.1)

130
(1.3)

150
(1.5)

¾”

22mm
21mm

5.53 180 125 315 6.75 298 218 360

Force 20TU
Force 20ITU

2.0 Bar Twin End
Positive and Negative
Head Shower Pump

3A

150
(1.5)

180
(1.8)

200
(2.0)

¾”

22mm
21mm

5.57 180 125 315 6.82 298 218 360

Force 30TU
Force 30ITU

3.0 Bar Twin End
Positive and Negative
Head Shower Pump

3A

220
(2.2)

260
(2.6)

300
(3.0)

¾”

22mm
21mm

6.79 210 125 315 8.10 298 218 360

Force 20SU
Force 20ISU

2.0 Bar Single End
Positive and Negative
Head Shower Pump

3A

150
(1.5)

180
(1.8)

200
(2.0)

¾”

22mm
21mm

4.96 183 125 315 5.94 298 218 360

Force 30SU
Force 30ISU

3.0 Bar Single End
Positive and Negative
Head Shower Pump

3A

210
(2.1)

260
(2.6)

300
(3.0)

¾”

22mm
21mm

6.20 213 125 315 7.24 298 218 360

Fuse

230/1/50

Regener

ativ

e

Pressure (kP

A/Bar) at 16ltr/min

Pressure (kP

A/Bar) at 8tr/min

Max pressure (kP

A/Bar) closed head

BSP

Push Fit

Isolators intergr

ated into the hoses

W

eight (Kg)

Length (mm)

Width (mm)

Height (mm)

W

eight (Kg)

Length (mm)

Width (mm)

Height (mm)

Summary of Contents for CT FORCE series

Page 1: ...Pump installation and warranty guide for the CT range of pumps CT FORCE CT Xtra and CT Bathroom ISSUE G JUL 2018 Models shown CT FORCE 15TU CT50 Xtra CT60B...

Page 2: ...UMPWISE TECHNICAL HELPLINE IMMEDIATELY on 0191 516 2002 01844 3212 ROI DO NOT REMOVE YOUR PUMP FROM THE SYSTEM WITHOUT FIRST RINGING PUMPWISE ON 0191 516 2002 01844 3212 ROI We encourage installers to...

Page 3: ...nder within 5m of measured pipe 2m MAX of 15mm pipework on inlet connections may be used Allow 100mm on all sides for ventilation Ensure pump is protected from frost If servicing two or more bathrooms...

Page 4: ...CT FORCE 20 PS 20 IPS 30 PS 30 IPS CT Xtra 55 55 59 85 85 89 are positive single impellor pumps Inlets and outlets must be vertical and plumbed appropriately It is essential to ensure that The cold st...

Page 5: ...the pump is as close to the hot water cylinder as possible no more than 5m in measured pipework away 5 Mount the pump upright shaft horizontal not screwed down 6 An anti gravity loop AGL of at least...

Page 6: ...oes to the outlet because either the outlet or the pipework to the outlet are above the height of the base of the cold water cistern Most instances of negative head systems occur in loft conversions o...

Page 7: ...done during commissioning Step 2 Connecting the pump Use only Salamander supplied AV couplers to connect the pump All associated pipework MUST be thoroughly flushed before making final connections to...

Page 8: ...valve is positioned above the cold feeds to the cylinder and to the pump aerated water is drawn into the pump as illustrated Chronic aeration of the pump occurs when this problem is combined with ina...

Page 9: ...ed e g Aga solid fuel appliance or very crudely by the boiler thermostat a Salamander approved HWS TMV must be used Approved flanges cylinders The 22mm No Stop Essex and the other approved top entry f...

Page 10: ...Fully automatic flow operated requiring 1ltr in 30 sec per side or 2ltr in 30 sec mixed Only applies to positive head pumps Temperature Maximum fluid temperature 60 C Pump noise Salamander has enginee...

Page 11: ...or notice The CT Xtra and CT Bathroom ranges of pumps are also fully WRAS approved CT Xtra has also been awarded Quiet Mark Part No Description Specification Performance Connection Type Pump Volumetri...

Page 12: ...Xtra 2 5 Bar Single End Positive Head Shower Pump 3A 170 1 7 200 2 0 220 2 2 21mm 3 86 185 120 160 4 59 293 213 226 Fuse 230 1 50 Regenerative Pressure kPA Bar at 16ltr min Pressure kPA Bar at 8tr mi...

Page 13: ...w switch sits in lowest position Float sticking in outlet Ensure no debris is in outlet area Flow switch malfunction Contact Technical Advice Line Reduced intermittent flow Incorrect or no anti aerati...

Page 14: ...ope of the Warranty SALAMANDER PUMPED SHOWER SYSTEMS LTD the Company Warrants subject to the terms and conditions below for the Warranty period s specified in paragraph 3 that the Company shall Repair...

Page 15: ...is completed online or over the phone within 15 days of purchase Pumps purchased prior to 1st January 2016 come with 2 years warranty iii CT Xtra CT Bathroom UK ROI products manufactured by the Compan...

Page 16: ...28 29 Notes Notes...

Page 17: ...er your warranty Apply online at www salamanderpumps co uk Apply by phone 0191 516 2002 Unit 2c Colima Avenue Enterprise Park West Sunderland SR5 3XE Get in touch we re here to help call us on 0191 51...