Technical specifications - CT Force
General specifications – CT Xtra & CT Bathroom
Applications
All Salamander pumps are designed to boost low pressure hot and cold supplies from
cistern-fed services. When supplies from a water heater or a combination boiler are to be
boosted contact the Salamander PumpWise helpline on 0191 516 2002 for guidance.
Voltage
230 volts, 50 Hz.
Motor type
Capacitor start and run induction type motor with stainless steel shaft and in-built resetting
thermal protection (complies with BS5000 part 11).
Maximum head
All CT Xtra and CT Bathroom pumps are rated for a maximum static head of 10 metres.
(100 kPa / 1.0 bar)
Anti-vibration couplers
Do not bend
Please refer to the Technical Specifications table for information on which AV Couplers are
supplied with each pump.
Mechanical seals
Rotary mechanical face seals are used. Scale deposits in water supplies can cause the
mechanical seal to stick if left for long periods without use. The pump must be run for at least
five minutes every four weeks to ‘exercise’ all working parts.
Connections
¾”
BSP male.
Initiation
Only applies to positive head pumps. Fully automatic, flow operated, requiring 1 litre in 30 sec
per side or 2 litres in 30 sec mixed.
Temperature
Maximum fluid temperature 60ºC.
Pump noise
Salamander has engineered this product range to be as quiet as possible, however no pump
is completely silent. Correct installation (anti-vibration couplers straight, rubber feet fitted)
will minimise noise, vibration and transmission noise.
Standards and approvals
Splash proof rating IPX2; complies with the requirements of
current British and European safety standards for household and
similar electrical appliances; meets with Compliance with European
Community Directives (CE). Due to continuous improvement and
updating specifications may be altered without prior notice.
The CT Xtra and CT Bathroom ranges of pumps are also fully WRAS
approved. CT Xtra has also been awarded Quiet Mark.
Part No.
Description
Specification
Performance
Connection Type
Pump Volumetrics
Packed Pump
Volumetrics
Electrical
Input
Pump
Type
Pump
Hoses
Isolators
Dimensions
Dimensions
CT FORCE
Force 15PT
Force 15IPT
1.5 Bar Twin End
Positive Head Shower
Pump
3A
110
(1.1)
130
(1.3)
150
(1.5)
¾”
22mm
21mm
4.96 180 120 160 6.02 298 218 205
Force 20PT
Force 20IPT
2.0 Bar Twin End
Positive Head Shower
Pump
3A
150
(1.5)
180
(1.8)
200
(2.0)
¾”
22mm
21mm
4.97 180 120 160 6.03 298 218 205
Force 30PT
Force 30IPT
3.0 Bar Twin End
Positive Head Shower
Pump
3A
220
(2.2)
260
(2.6)
300
(3.0)
¾”
22mm
21mm
6.22 210 120 160 7.34 298 218 205
Force 20PS
Force 20IPS
2.0 Bar Single End
Positive Head Shower
Pump
3A
150
(1.5)
180
(1.8)
200
(2.0)
¾”
22mm
21mm
4.33 183 120 160 5.17 298 218 205
Force 30PS
Force 30IPS
3.0 Bar Single End
Positive Head Shower
Pump
3A
210
(2.1)
260
(2.6)
300
(3.0)
¾”
22mm
21mm
5.61 213 120 160 6.48 298 218 205
CT FORCE Universal Pumps
Force 15TU
Force 15ITU
1.5 Bar Twin End
Positive and Negative
Head Shower Pump
3A
110
(1.1)
130
(1.3)
150
(1.5)
¾”
22mm
21mm
5.53 180 125 315 6.75 298 218 360
Force 20TU
Force 20ITU
2.0 Bar Twin End
Positive and Negative
Head Shower Pump
3A
150
(1.5)
180
(1.8)
200
(2.0)
¾”
22mm
21mm
5.57 180 125 315 6.82 298 218 360
Force 30TU
Force 30ITU
3.0 Bar Twin End
Positive and Negative
Head Shower Pump
3A
220
(2.2)
260
(2.6)
300
(3.0)
¾”
22mm
21mm
6.79 210 125 315 8.10 298 218 360
Force 20SU
Force 20ISU
2.0 Bar Single End
Positive and Negative
Head Shower Pump
3A
150
(1.5)
180
(1.8)
200
(2.0)
¾”
22mm
21mm
4.96 183 125 315 5.94 298 218 360
Force 30SU
Force 30ISU
3.0 Bar Single End
Positive and Negative
Head Shower Pump
3A
210
(2.1)
260
(2.6)
300
(3.0)
¾”
22mm
21mm
6.20 213 125 315 7.24 298 218 360
Fuse
230/1/50
Regener
ativ
e
Pressure (kP
A/Bar) at 16ltr/min
Pressure (kP
A/Bar) at 8tr/min
Max pressure (kP
A/Bar) closed head
BSP
Push Fit
Isolators intergr
ated into the hoses
W
eight (Kg)
Length (mm)
Width (mm)
Height (mm)
W
eight (Kg)
Length (mm)
Width (mm)
Height (mm)