Salamander Pumps CombiBoost Installation And Warranty Manual Download Page 4

4

5

Application notes – continued

4. Isolation valves

Good plumbing practice is to fit full bore isolating valves into the inlet and outlet pipe work of the 

pump to facilitate service and removal of the pump. To install immediately after the stop tap, the 

isolation valve should be fitted to the pump outlet. To install to a combi boiler only, the isolating 

valve should be fitted to the pump inlet.

5. Holding the HomeBoost™/CombiBoost during installation

To hold HomeBoost™/CombiBoost during installation, spanner flats (24mm) have been provided 

on the brass neck outlet. See Figure 1. Any tool used to hold HomeBoost™/CombiBoost while the 

pipework is connected must be located on the brass portion of the neck to avoid damage to the 

polymer pump body.

6. Electrical requirements

HomeBoost™ /CombiBoost must be connected to the electrical supply using the mains cable with 

the attached plug. This plug must be connected to an accessible socket that has been installed in 

compliance with IET Wiring Regulations. 
The plug must be  accessible at all times. 
If the supply cord is damaged, it must be replaced by the manufacturer, it’s service agent, or 

similarly qualified person in order to avoid a hazard.
All pipe work must be cross-bonded in accordance with the IET Regulations. 
HomeBoost/CombiBoost™ is supplied with a 3A fuse fitted. Higher rated fuses MUST NOT be 

used.
If installed by a Part P qualified installer, the pump may be fitted via a 3A fused mains spur 

without invalidating the warranty. 

Typical installations

Figure 1: Spanner flats to hold the HomeBoost/

CombiBoost during installation

 

110mm 

square

175mm inlet to outlet vertical height

195mm overall

length including 

inlet neck 

Spanner flats on brass pump housing

Plastic pump body

Figure 2: Inlet and outlet

Inlet

Outlet

Figure 3: Ideal location

1.

2.

Mains stop tap

Check valve

Combi-boiler

Drain off

Isolating

Ball valve

Tap connector

Tap connector

Isolating
Ball valve

Isolation valve 

for combi-boiler

Figure 4: Modified pipe work  

for clearance

Pipe centre to wall 37mm

1.

Combi-boiler

2.

Combi-boiler

Figure 5: Typical installation locations

NOTE: Refer to pre-installation checklist for suitability

Figure 6: Earth continuity (4mm

2

 earth 

connection cable)

Figure 7: Incorrect installation location

NOTE: Refer to pre-installation checklist for suitability

Figure 8: Installation orientation

Inlet

Outlet

Inlet

Outlet

Inlet

Outlet

Inlet

Outlet

NOTE: Pump can be installed horozontally or vertically 

but not upside down.  

Summary of Contents for CombiBoost

Page 1: ...ISSUE 1 JULY 2020 Pumpinstallationandwarrantyguidefor CombiBoostandHomeBoost HomeBoost only...

Page 2: ...l water flow reaches 12lpm or more naturally CombiBoost is designed to boost your existing incoming mains water supply up to 10 litres per min lpm Correct installation is essential for safe operation...

Page 3: ...ressure of 1MPa 10 bar In line with good plumbing practice and water regulations ensure that a non return valve has been fitted directly after the mains stop tap to the house Earth continuity must be...

Page 4: ...similarly qualified person in order to avoid a hazard All pipe work must be cross bonded in accordance with the IETRegulations HomeBoost CombiBoost is supplied with a 3A fuse fitted Higher rated fuse...

Page 5: ...designed to boost low mains water flow into a domestic house to improve low water flow from the mains supply at peak demand times These pumps can be used in two distinct applications 1 Boosting the in...

Page 6: ...p running Fault Probable cause Recommended solution Pump will not start Electrical Check power supply appliance plugged in and electrical power on Check fuse Check circuit breaker Inlet outlet connect...

Page 7: ...o provide a support service second to none Installers and consumers can be sure of a speedy response to requests for technical help guidance and advice Yourwarranty HomeBoost comes with a three year w...

Page 8: ...e helpline for installation advice Once installation has been completed and the system has been tested to your satisfaction please assist the customer by giving them the information needed to complete...

Page 9: ...teryourwarranty Apply online at www salamanderpumps co uk Apply by phone 0191 516 2002 HomeBoost only Getintouch we reheretohelp calluson 01915162002 Unit2cColimaAvenue EnterpriseParkWest Sunderland S...

Reviews: