background image

***The compatible PIXIE secondary device list is subject to change due to product evolution and availability.

Scenario

Scenario

When movement is detected

When a new movement is detected 
within the duration of the last detection

When movement is detected

When there is no movement detected

Load response

Remark

Below the threshold

Below the threshold

Above the threshold

NA

Stays at OFF

Stays at OFF

The sensor is on standby

The load is kept on, the hold-time 
timer restarts from the new signal

The load is turned on, and kept 
on during the hold-time 

If there is no new movement 
detected, the load will be turned 
off when hold-time elapse

Hold-time is added continually

The sensor will not respond to 
infrared source movement when 
ambient brightness is higher than 
threshold setting

No response, 
stays at OFF

No response, stays at OFF

Flash once

Flash once

Ambient bightness

LED Indicator

Override-On mode

Override-Off mode

Load response

Remark

The load is kept off

The load is kept on

The load is always on regardless of 
movement or ambient brightness

The load is always off regardless of 
movement or ambient brightness

Stays at green

Stays at blue

LED Indicator

Option 2

Option 1

Option 3

How to switch to Override-On mode

How to switch to Override-Off mode

How to return to Motion sensor mode

Via the App,
in the sensor control page

Via the App,
in the sensor control page

Via the App,
in the sensor control page

Via a paired PIXIE secondary device,
double press the button

Via a paired PIXIE secondary device,
triple press the button

Via a paired PIXIE secondary device,
single press the button

Switch off the power to the 
sensor, wait for 10 seconds,  then 
resupply power to the sensor

-

-

Together with schedule function in the App, switching modes in a routine help customize the sensor to users needs. For example, the sensor can be set to switch 
to Override-On mode at 6:00PM everyday for task purpose, and switch to Motion sensor mode at 11:00PM everyday for security purpose.

Override-On mode and Override-Off mode

5.3 Working modes

Three working modes are built in the sensor:

Motion sensor mode (or namely Auto mode): 

When the ambient brightness corresponds to brightness threshold setting, the sensor is monitoring infrared source 

movements in the detection field. The load is turned on when movement is detected, and the load is turned off when there is no more movement detected 
within hold-time

Override-On mode (or namely Always-On mode):

 The load is always kept ON regardless infrared movements in the detection range

Override-Off mode (or namely Always-Off mode): 

The load is always kept OFF regardless infrared movements in the detection range

Before being added to the App, the sensor works in Motion sensor mode by default.

After being added into the App, the sensor can work in all 3 modes, see below for how to switch modes

5.4 Warm-up

When power is supplied to the sensor, the LED indicator of the sensor will flash slowly for 20-30 seconds. During this period, the load is kept at ON status regardless 
of motion or ambient brightness. This is warm-up process of the sensor, to get ready for the functionalities. When the LED indicator stops flashing, and the load is 
turned OFF, the warm-up process is finished. After warm-up, the sensor will always enter Motion sensor mode as default setting.

5.5 Function and LED indicator response

Motion sensor mode.

5.6 Work with PIXIE secondary devices

The  sensor  can  pair  and  work  with  three  PIXIE  secondary  devices***: 
SMF/BTAS, SMRM/BTAS, SMRP/BTAS 

Note: Pairing operation is only available in the App. Please add the sensor 
into the App before commencing pairing operation.

Operation on a paired PIXIE secondary device and correspondent functions 
on the sensor

Single press: 

Switch the sensor to Motion sensor mode

Double press:

 Switch the sensor to Override-On mode

Triple press:

 Switch the sensor to Override-Off mode

5.7 Test and configuration

Option 1-Test and configure in the App (Recommended)

1. Supply power to the sensor,after 30 seconds’ warm-up, the sensor is ready 
to operate
2. Add the sensor into the SAL PIXIE or PIXIE PLUS App
3. Follow the step-by-step guide in the App to finalise the configuration of 
the sensor 

Option 2-Test and configure manually

1. Turn the TIME dial to full clockwise to the minimum, which is 10 seconds set
2. Turn the LUX dial to full clockwise to the ‘Sun’ icon, which is the maximum 
(Note: When testing the sensor under daylight, please always turn LUX dial to 
the maximum position, otherwise the sensor will not operate)
3.  Supply  power  to  the  sensor,  after  30  seconds’  warm-up,  the  sensor  is 
ready to operate
4.  Walk  slowly  around  the  desired  detection  field,  to  confirm  the  load  is 
activated upon movement from within the desired detection field
5. Set the brightness threshold to the desired level
6. Set the hold-time to the desired time for normal operation

Reviews: