4) The battery should be stored in accordance with the storage
requirements mentioned above, and the battery should be
installed within 6 months since delivered from the factory and
used with compatible inverters;
Notice
·The battery remains 40% power when it is sent from the factory.
·The longer the battery is stored, the DOD value is getting bigger.
When the battery remaining voltage fails to reach the startup voltage
requirement, the battery may be damaged.
·Judgment condition: Close the battery breaker switch and press the
BMS switch. At this time, if the LED light is flashing, it is running
normal. If the LED light is off, the battery is in faulty.
The battery cannot be disposed of as household refuse. When the
service life of the battery reaches to the limit, it is not required to
return it to the dealer or SAJ, but it must be recycled to the special
waste lithium battery recycling station in the area
7.3 Cleanliness
Clean the enclosure lid, LCD and LED indicator of the inverter with
moistened cloth with clear water only. Do not use any cleaning