background image

 

 

The assembly works the other way round! 
After mounting the grinding wheel, let the machine run for a short period of 
time and in a safe position. If the machine does not run easily, stop working 
immediately. 

Use only original accessory! 

 

In order to protect the operator, motor and drill bit, the concrete grinder is 
equipped with an electronic and thermal overload protection. 

Thermal: 

In case of permanent overload, a      thermocouple  protects 
the  motor  against  destruction.  In  this  case,  the  tool  
switches off automatically and can only be restarted after a 
certain  cooling  period  (approx.  2  minutes).  The  cooling 
period  depends  on  the  heating  of  the  motor  winding  and  
the ambient temperature. 

Electronic:          In  case  of  overload,  the  electronic  facility  will  deenergize     

the  tool.  After  discharge  and  reengagement  one  can  drill 
again. 

 

Before the beginning of maintenance or repair works you 
have to disconnect the plug from the mains. 

Repairs  may  be  executed  only  by  appropriately  qualified  and  experienced 
personnel.  After  every  repair  the  machine  has  to  be  inspected  by  an  
electric specialist. 
Due to its design, the machine needs a minimum of care and maintenance. 

However, the following points always have to be observed: 

 

Always keep the power tool and the ventilation slots clean. 

 

During work, please pay attention that no particles get inside the 
machine. 

 

In case of failure, a repair has to be carried out by an authorised 
service workshop. 

 

 

Raw material recycling instead of waste disposal 

 

To avoid damages on transportation, the power tool has to be delivered in  
a  sturdy  packing.  Packaging  as  well  as  unit  and  accessories  are  made  of 
recyclable materials and can be disposed accordingly. 

Overload Protection 

Care and Maintenance 

Environmental Protection 

Summary of Contents for Norton Clipper CG180

Page 1: ...CG180 OPERATING INSTRUCTIONS...

Page 2: ...W VOLTAGE 2006 95 CE ELECTROMAGNETIC COMPATIBILITY 2004 108 CE NOISE 2000 14 CE and the European standard EN 60 745 Valid for machines with serial number from 20150000 Storage location of the technica...

Page 3: ...fully Keep your work place clean and avoid dangerous situations In order to protect the user take precautions During work you should wear ear protectors goggles dust mask protective gloves and sturdy...

Page 4: ...mended by the manufacturer These have a small weight and a high concentricity Using other grinding wheels can cause an overload of the machine or damage of the bearings and danger to the user Safe wor...

Page 5: ...s on the switch the cable or plug Pay attention that the speed indicated on the grinding wheel meets or is higher than the max speed indicated on the machine Grinding wheels have to be stored and used...

Page 6: ...sing with floor guiding device Switching on press the on off switch and keeping it pressed engage the lock on button Switching off press the on off switch and release it again Attention In case of eve...

Page 7: ...ld burn your hands or get cut or ripped by the segments Therefore always use protective gloves when changing the grinding wheel Before any work on the tool disconnect the plug from the mains First of...

Page 8: ...r discharge and reengagement one can drill again Before the beginning of maintenance or repair works you have to disconnect the plug from the mains Repairs may be executed only by appropriately qualif...

Page 9: ...ed values determined according to EN 60 745 The declared vibration emission level represents the main applications of the tool However if the tool is used for different applications with different acc...

Page 10: ...e must be well ventilated The use of a dust mask of filter class P2 is recommended According to our general terms of delivery for business dealings suppliers have to provide to companies a warranty pe...

Page 11: ...VERS 2017 06 10 CG180_MAN_EN...

Page 12: ......

Reviews: