A2CH3 F16 – OPERATING INSTRUCTIONS
INDEX DATE N°
00 06/02/09
DC69020
4/16
Various information relating to air connection is gathered in diagram 1.
Diagram 1
Index Designation
1 Air
supply
1.1
Static working pressure: 2-5 Bar or 29-72.5 PSI. Please contact us for different air setting
Air supply quality according to ISO 8573-1 (dry air or nitrogen)
Dust: Class 2
Dew point: Class 2
1.2
Oil quality: Class 0 (No oil)
2 Pressure
regulator
3
Pneumatic valves 3/2/2
4
Tap 3/8 – 18 NPT
5
Tube dimension: Ø 08x10mm (5/16"x3/8") – Max. length between pump and pressure regulator: 10 feet or 3
meters
6
Optic fiber (optional, please contact us)
7
Exhaust tap: G3/8" (standard muffler)
8
Exhaust tube (optional, please contact us)
8.1
Minimum inlet diameter: Ø 3/8"x1/2" or 10x13 mm. Max length: 10 feet or 3 meters
9 Temperatures
9.1
Environment: 50 to 140°F or 10 to 60°C
9.2
Maximum fluid temperature: 185°F or 85°C. Please contact us for higher temperature
10 No
muffler
III.3.2 – Fluid connections
The pump is self-priming. The inlet is at the bottom and the outlet at the top.
The reference of your pump is A2CH3 F16. It is supplied with flared fittings (at inlet and outlet) suitable
for 3/4"x1" or 22x25 mm tube.
III.4 – Initial Tests and Adjustments
Before commissioning the pump, we recommend to test it dry with a supply pressure of 50 PSI or
3.5 bar to ensure the system works correctly (See III.3.1 for the correct connections).
Before using the pump with chemicals please check:
•
The 4 manifolds (P/N 9366-100) are tight,
•
The air/nitrogen supply is dry, clean and between 29 and 72.5 PSI or 2 and 5 bar (please contact
us for different values)
•
The inlet and outlet fluid connections are correctly fitted and tight.