background image

- 8 -

Inserting 3 AA fresh batteries as show in Figure 5

.

Close the

battery door. Make sure that the gasket (around the battery

compartment) is properly seated in its trace prior to closing the

door and Tighten the set screw.

Note:

We recommend installing Lithium AA batteries for

outdoor sensors in cold weather environments

The Integrated outdoor sensor LED indicator(White button) will

light for 3 seconds, and then flash once per 16 seconds

thereafter. Each time it flashes, the sensor is transmitting data.

Figure 5

Note:

If the sensor does not power up after inserting the

batteries, press the reset button as shown in Figure 6.

Summary of Contents for WS0835

Page 1: ...4 3 Connect Sensors with Display Console 13 3 5 Sensor Operation Verification 14 4 Sensors Pre Installation 15 4 1 Test the Sensors Before Installation 15 4 2 Site Survey Before Installation 15 4 3 B...

Page 2: ...ration of Temperature Mode 34 9 2 Calibration of Humidity Mode 34 9 3 Calibration of Sensors Mode 35 10 Other Features of Display Console 40 10 1 Weather Forecasting 40 10 2 Weather Icons 40 10 3 Moon...

Page 3: ...ver install the weather station in a storm Warning Installing your weather station in a high location may result in injury or death Perform as much of the initial check out and operation on the ground...

Page 4: ...5 5 x 3 7inch 139 6 93mm 1 Integrated Outdoor Transmitter Dimensions 13x11x5 9 inch 330x280x150mm 1 Foot Mounting with pole insert Dimensions 4x3x1 5inch 101x76x37mm 1 Mounting Bracket Back Plate pole...

Page 5: ...5 QTY Item Image 2 Pole mounting nuts M3 bolts 3 4 Pole mounting nuts M5 bolts 5 4 Tapping screws 1 Manual 1 Power Adapter Figure 1...

Page 6: ...t be powered and updating before powering up the console or the console will stop scanning and connecting with the sensors The following illustration shows the full segment of integrated outdoor senso...

Page 7: ...can permanently damage the outdoor sensors The solar panel does not charge the batteries so rechargeable batteries are not recommended Figure 3 Remove the battery door on the back of the sensor by re...

Page 8: ...et screw Note We recommend installing Lithium AA batteries for outdoor sensors in cold weather environments The Integrated outdoor sensor LED indicator White button will light for 3 seconds and then f...

Page 9: ...6 3 4 Display Console 3 4 1 Layout of Display Console The following illustration shows the full segment LCD display for feature description purposes only and will not appear like this during normal o...

Page 10: ...ction 18 Wind speed units of measure 19 Wind speed Gust display 20 Wind speed average display 21 Wind speed average HI alarm icon 22 Rainfall display 1h 24h week month total 23 Pressure REL and ABS di...

Page 11: ...11 Figure 7 1 Fold out the desk stand and see DC jack on the left as shown in Figure 8 Figure 8 2 Insert the DC plug correctly as shown in Figure 9 Figure 9...

Page 12: ...until 90 degrees as shown in figure 10 Figure 10 4 If you want to hang on the wall turn the DC plug down until 0 degrees and closed the desk stand as shown in Figure 11 Figure 11 Note The battery is a...

Page 13: ...battery door and unfold out the desk stand to place the console in the upright position Note The battery is a back up of weather station console saving console settings when powered off from adaptor...

Page 14: ...r station sensors is too close or too far away it may not receive a proper signal 3 5 Sensor Operation Verification The following steps verify proper operation of the sensors prior to install the sens...

Page 15: ...the weather station for one week before installing it in the permanent location In this period you can check out all of the functions ensure proper operation and familiarize with the professional wea...

Page 16: ...reach up to100ft 30m due to building obstructions walls and interference 5 Radio interference such as PCs radios or TV sets can in the worst case entirely cut off radio communication Please take this...

Page 17: ...io frequency will not pass through metal barriers such as aluminum siding If you have metal siding align the remote and console through a window to get a clear line of sight The following is a table o...

Page 18: ...stallation you will need to calibrate the wind direction Note There are four alphabet letter of N E S and W around the wind direction N is North E is East S is South W is West Northern Hemispheres Sou...

Page 19: ...time area in Location division Check the detailed step of setting the time area in the part 15 of Chapter 7 2 5 1 2 Southern Hemispheres SOU References For Southern Hemisphere installations ignore the...

Page 20: ...NOR or SOU on the Display Console and the directions of the sensor have to be adjusted to match with your real location If the wind direction sensor is not positioned correctly during installation per...

Page 21: ...21 Then tighten the mounting pole to your existing mounting pole with the four bolts 5 and nuts M5 or fix it on the flat surface with four tapping screws as show in Figure 15 Figure 15...

Page 22: ...outdoor sensor to the mounting pole brackets with foot mounting two 3 bolts and M3 nuts Then tighten the mounting pole to your existing mounting pole with the four bolts 5 and nuts M5 or fix it on the...

Page 23: ...as alkaline and lithium together 7 Display Console Operation 7 1 Quick Display Mode Note The display console has five keys for easy operation SET key and ALARM key on the right side MIN MAX key SNOOZE...

Page 24: ...CHANNEL or MAX MIN key to toggle between absolute pressure and relative pressure 4 Outdoor Temp Press CHANNEL or MIN MAX key to toggle among temperature dew point and feels like 7 2 Set Program Mode...

Page 25: ...ain to enter the Day Month format mode Press the CHANNEL or MIN MAX key to switch between M D D M 5 Change Month Press the SET key again to set the calendar month Press the CHANNEL key or MIN MAX key...

Page 26: ...Press the SET key again to change the pressure units of measure Press the CHANNEL key or MIN MAX key to toggle the pressure units between mmhg inHg or hPa 13 Pressure Threshold Setting default level...

Page 27: ...Viewing and Reset Mode 7 4 1 Max Record Viewing and Reset In normal mode press do not hold the MIN MAX key the MAX icon will be displayed in date area Press the SET key to view max values of rainfall...

Page 28: ...the MIN MAX key for three seconds to clear all Min values pressure temperature and humidity minimum values Press the SNOOZE key to exit the min max checking and clearing mode return to normal display...

Page 29: ...conds BL OFF icon will be displayed for three seconds in the date area Note If the display console plugged into AC adapter power the time area will display AC ON and the backlight will remain on It is...

Page 30: ...time Alarm 1 time and HI alarm parameters of indoor temperature and humidity outdoor temperature and humidity 1h rainfall absolute pressure wind gust wind average are displayed Press SET key to view A...

Page 31: ...l begin flashing alarm hour To save the alarm setting and proceed to the next alarm parameter Press do not hold the SET key To adjust the alarm parameter press the CHANNEL key or MIN MAX key to increa...

Page 32: ...con will continue to flash until the humidity falls below 56 at which point the alarm will reset and must increase above 60 to activate again 1 Alarm hour alarm 1 2 Alarm minute alarm 1 3 Alarm hour a...

Page 33: ...mote sensor s always displays the un calibrated or measured value Note The measured humidity range is between 10 and 99 Humidity cannot be accurately measured outside of this range Thus the humidity c...

Page 34: ...EL keys at the same time for five seconds to enter the temp calibration mode The indoor temperature will begin flashing Press the CHANNEL key or MAX MIN key to increase or decrease the temperature rea...

Page 35: ...xit the humidity calibration mode at any time press the SNOOZE LIGHT button on the top of the display console If no operation is performed the calibration mode will timeout in 30 seconds Note The Humi...

Page 36: ...increase or decrease rapidly Press the ALARM key to reset current value Example The calibrated pressure sources measure 28 37 inHg The display console pressure reads 28 75 inHg Offset 28 37 28 75 0 38...

Page 37: ...your location would be at if located at sea level is generally higher than your measured pressure Thus your absolute pressure may read 28 62 inHg 969 mb at an altitude of 1000 feet 305 m but the rela...

Page 38: ...y for three seconds to increase or decrease rapidly Press the ALARM key to reset current value Note The wind gust is also affected by the wind speed calibration factor Discussion Wind speed and wind g...

Page 39: ...n factor from 0 75 to 1 25 where Calibrated Rain Calibration factor x Measured Rain Press and hold the CHANNEL or MAX MIN key for three seconds to increase or decrease rapidly Press the ALARM key to r...

Page 40: ...he pressure decreases the weather degrades cloudy to rain The weather forecast is an estimation or generalization of weather changes in the next 24 to 48 hours and varies from location to location The...

Page 41: ...previous condition is cloudy Cloudy Pressure is falling and the previous condition is partly cloudy or Pressure is rising and the previous condition is rainy Rainy Pressure is falling and the previous...

Page 42: ...re 10 4 1 Feels Like Temperature Feels like temperature is a combination of Heat Index and Wind Chill 1 Temperatures less than 4 4 C 40 F the wind chill is displayed as shown in the National Weather S...

Page 43: ...he negative or positive rate of change of pressure signifying a change in the weather can be adjusted from 2 hPa to 4 hPa default level 2 hPa The lower the level pressure threshold setting the higher...

Page 44: ...batteries before starting the reset operation 11 Maintenance Clean the rain gauge of Integrated Outdoor Transmitter once every 3 months Unscrew the rain collector funnel by turning it 30 counter cloc...

Page 45: ...45 A Remove the rain collector funnel B Install the collector funnel Replace the Integrated outdoor sensor batteries once every 1 2 years...

Page 46: ...ired the remote search icon will turn off and the current values will be displayed The maximum line of sight communication range is 100m 330ft and 30m 100ft under most conditions Move the sensor assem...

Page 47: ...to stabilize due to signal filtering The indoor and outdoor temperature sensors should agree within 2 C 4 F the sensor accuracy is 1 C 2 F Use the calibration feature to match the indoor and outdoor...

Page 48: ...tions for the measured parameters Measurement Range Accuracy Resolution Indoor Temperature 0 to 60 C 32 to 140 F 1 C 2 F 0 1 C F Outdoor Temperature 40 to 60 C 40 to 140 F 1 C 2 F 0 1 C F Indoor Humid...

Page 49: ...luded Integrated Outdoor Sensor 3xAA alkaline batteries or Lithium batteries not included the batteries provide backup power when there is limited solar energy Note Solar panel doesn t charge the batt...

Page 50: ...luded Battery life Minimum 12 months for base station with excellent reception Intermittent reception may reduce the battery life Minimum 12 months for sensors use lithium batteries in cold weather cl...

Page 51: ...51...

Page 52: ...Manufacturer Sainlogic High Tech Innovation Co LTD F9 De Zhong Industrial Park Li Pu Street Shenzhen China Post 518001 Phone 86 755 80759871 www sainlogic com Email Info sainlogic com FCC ID 2ALHJ WS0...

Reviews: