Measuring incline angle
m
、
Load cell size
From the belt scale data sheet located in the front of this manual, determine the load cell size
(example: 250.0). record the weight below:
kg
(
load cell size
)
n
、
load cell sensitivity
From the nameplate of load cell, determine the load cell sensitivity in mV/V (example:
3.000mV/V)
Record below:
mV/V
(
load cell sensitivity
)
o
、
load cell resistance
Measue each load cell’s output resistance using digital voltameter
(example: 350.00)
Record below:
ohm
(
load cell resistance
)
p
、
Conveyor belt length, measure belt revolution one cycle length to the nearest 1mm with
tape measure.
Record below
:
mm
(
conveyor belt length
)
Press “PAGE DOWN” soft key from the Initial Setup 5 Menu, the sixth page of Initial Setup
Menu is displayed as follows:
The setting value of the speed mode are “Simulated” and “Actual”.
When “Simulated” is selected, the integrator will generate an analog signal for speed input.
2006-3-21
12:00:00
Scale#1
INITIAL SETUP 6
Speed Mode
:
[SIMULATE]
Speed Channel
:
[CHANNEL 1]
Press
↑↓
key, then press ENT!
MAIN
PAGE
PAGE
MENU
DOWN
UP