2. Set first light at

NAST

and rest of fixtures on SL1 Mode. It means first fixture will

be the master fixture which send same operating command to other fixtures of
the network(we call those other fixture on Slave mode or Sl1 or Sl2)

3. After done this setting of No 2, now all fixtures are connected and ready to go or

ready to get command of the first fixture or master fixture. Now you can set
different operating modes, example: sound active, static color, auto or fade. Once
you set the modes at first master unit other fixtures will start to project same the
effect as master unit did.

Master and salve connection setting by using the DMX controller

Connect the DMX controller and Fixture by using the DMX cable. Link other units with first

fixture and rest of unit, set all fixtures at Sl1 or Sl2 mode. Once you set the fixture it will

appear “A001” or “STBY” it means now fixture ready to go with DMX controller.

DMX Control:

Operating through a DMX controller gives the user the freedom to create their own

programs tailored to their own individual needs. Follow the directions below to set your

DMX Mode and address.

Before connecting to DMX controller, your fixture has different DMX channel modes,

please select your desired mode by pressing the DMX Mode button, then using the “up” or

“down” buttons to scroll through the DMX Channel Modes. Set the mode Sl1 or Sl2 before

you address the fixture.

How to group fixtures/ project different colors in different fixtures by using same

DMX controller/how to set DMX address so user can control the fixture and

project different color at same time by same DMX controller?

1. First make sure how many groups you are going to create which you are planning to control

by 1 DMX controller. In 1 group you can link minimum 1 to maximum 33 fixtures.

2. Link all fixtures with each other by Cable or link each group in DMX splitter. DMX splitter is a

device which helps to split the DMX signals to different group, DMX splitter will be useful

and needed if you are going to control over 33 fixtures at once. In market you can find 8

channels, 16 channels and 32 channel DMX splitter.

3. Once you made the link or network, Now you can put address value in “Addr” or “A001”.

Remember always that you need to put gap between 1

st

group and second group or third

group or in each group depends on the DMX channel. On Hex Lion par 18 it has 7/12 DMX

channel, let’s say user choose 12 DMX channel and want to make the 4 group each group it

has 10 fixtures. Set first 10 pcs fixtures to A001, set second group’s all 10pcs fixtures at

A013, set third group all fixtures at A026 and set all fixtures of the group 4 in A039. It

means that DMX controller feeder 1- 12 it will control fist group, 13-25DMX controller

feeder it will control group 2, 26-38DMX controller feeder will control the group 3 and 39-51

DMX controller feeder it will control the group 4. We put here gap of the 12 because we set

the light at 12DMX channel mode. hereA001(01), A013(13), A026 (026) and A039(39)

those in bracket (01),(13), (26) and (39) those it will be referred as DMX channel number 1

of each group also DMX controller’s feeder number. Use the feeder of the DMX controller to

control the fixtures separately.

Summary of Contents for SW-E6V18

Page 1: ...www sailwinlight com info sailwinlight com 1 18 18W IP65 WATERPROOF LED PAR LIGHT SW E6V18 User Manual...

Page 2: ...n case you are not qualified to do so 4 Never connect the power when cover is removed 5 Never use this unit if it becomes damage 6 Never connect this unit to any if dimmer and or power pack 7 If the u...

Page 3: ...DMX512 Control Mode Sound Active stand alone Color Effects RGBAW UV 6in1 Color Mixing PVM Dimmer 400HZ 6666 steps DMX Channel 7 12CH Beam Angle 20 25 40 degree IP Rate IP65 Battery Last Time 100 12 Ho...

Page 4: ...l Do not attempt to operate this unit if it becomes damaged This unit is intended for indoor use only use of this product out doors voids all warranties During long periods of non use disconnect the u...

Page 5: ...e middle When a fixture is assigned a DMX address of A0011 the DMX controller knows to send DATA assigned to address A001 to that unit no matter where it is located in the DMX chain Controller Data Ca...

Page 6: ...5 Pin XLR DMX Connectors Some manufactures use 5 pin DMX 512 data cables for DATA transmission in place of 3 pin 5 pin DMX fixtures may be implemented in a 3 pin DMX line When inserting standard 5 pi...

Page 7: ...ess MENU UP DOWN SLND NAST UP DOWN SHND COLO CO1 to CO15 Static color and choose CO12 for the custom color 7 Choose NANU then Enter then put the value of each color RGBA or RGBW then Enter to display...

Page 8: ...same DMX controller how to set DMX address so user can control the fixture and project different color at same time by same DMX controller 1 First make sure how many groups you are going to create whi...

Page 9: ...2 0 No action blackout 1 255 GREEN dimmer Bright CH3 0 No action blackout 1 255 BLUE dimmer Bright CH4 0 No action blackout 1 255 Amber dimmer Bright CH5 0 No action blackout 1 255 White Dimmer Bright...

Page 10: ...find out the broken point do welding on that breakpoint Cleaning Due to fog residue smoke and dust cleaning the internal and external optical lenses must be carried out periodically to optimize light...