2 INSTALLATION
H2192
CABLE 53 H2192 - T213X
11x0.75 mm
2
shielded multicable, max length 30 meter.
H2192
T2130
T2131 / T2135
SIGNAL
ST5
ST2
ST3
ST7
ST6
ST12
ST8
1
1
1
MUTE RX
2
2
2
VF/AE CURRENT
3
5
5
SUPPLY ON/OFF
4
9
9
0dBm COMMON
5
10
10
AUX AF TO TX
7
12
12
0dBm
8
13
13
TX-KEY
9
16
16
SP-BUS INTERRUPT
10
1
1
MUTE OUT
11
15
15
- BATT
2
10
2
10
MUTE OUT/GROUND
CABLE 54 H2192 - TELEX ALARM and MUTE IN.
Telex alarm out:
One times make and break relay contact.
Max. ratings:
30V and 2Amp
Battery outputs:
Fused with 1Amp fuse.
Mute in to RM2150/51:
Relay coil.
Max. voltage:
35V, 20
o
C.
Min. voltage:
9V, 20
o
C.
Coil resistance:
2250 ohm +/- 300 ohm.
H2192
H2184
SIGNAL
CONNECTION
BOARD (1)
CONNECTION
BOARD (2)
ST7
ST2
ST1
ST2
1
+ BATT
2
4
EXT. ALARM, NO
3
9
EXT. ALARM, C
4
EXT. ALARM, NC
5
MUTE IN RM2150
6
MUTE IN RM2151
7
- BATT
1
1
RING INDICATOR / + SES ALARM
2
2
GROUND / - SES ALARM
For more detailed information,
please see the manual for H2185 chapter 2.2.7
CABLE 56 H2192 - CHARGER I AND CHARGER II (N2174)
Two times shielded multicable 7x0.75mm
2
CHARGER I
CHARGER II
H2192
N2174
SIGNAL
(5-0-26446)
ST1
ST7
1
1
- SHUNT
2
2
+ SHUNT
3
3
- VS
4
4
MAN.
5
5
26V
6
6
AUTO
7
NC
H2192
N2174
SIGNAL
(5-0-26446)
ST2
ST7
1
1
- SHUNT
2
2
+ SHUNT
3
3
- VS
4
4
MAN.
5
5
26V
6
6
AUTO
7
NC
CABLE 57 BATTERY SUPPLY TO INMARSAT-C AND VHF
Current concuption:
10 Amps
cable dimensions:
up to 8 meters 6mm
2
H2192
N2161
SIGNAL
P3
P4
+ BATT
P4
P3
- BATT
CABLE 58 BATTERY SUPPLY TO HF SSB
Current concuption:
4 Amps
cable dimensions:
up to 30 meters 6mm
2
H2192
H2182
SIGNAL
P5
HF +
+ BATT
P4
AUX -
- BATT
CABLE 59 EMERGENCY LIGHT
Connectionboard module 2
29493
Emergency
light switch
40W Max.
5-0-29493
2
ST9
3
1
NO
C
NC
29501
PAGE 2-12