2 INSTALLATION
H2192
PAGE 2-11
CABLE 51
H2192 - AUX.
Fast mute out:
Two times make and break relay contacts.
Max. ratings:
30V and 2 Amp
Battery outputs:
Fused with 1 Amp fuse.
H2192
SIGNAL/RELAY CONTACT
ST6
1
+ BATT
2
FAST MUTE OUT, NO
3
FAST MUTE OUT, C
4
FAST MUTE OUT, NC
5
FAST MUTE OUT, NO
6
FAST MUTE OUT, C
7
FAST MUTE OUT, NC
8
- BATT
CABLE
52
H2192 TO AUX.
Slow mute out:
Four times make and break relay contacts.
Max. ratings:
30V and 2 Amp
Battery outputs:
Fused with 1 Amp fuse.
H2192
SIGNAL/RELAY CONTACT
ST4
1
+ BATT
2
FAST MUTE OUT I, NO
3
FAST MUTE OUT I, C
4
FAST MUTE OUT I, NC
5
FAST MUTE OUT I, NO
6
FAST MUTE OUT I, C
7
FAST MUTE OUT I, NC
8
FAST MUTE OUT II, NO
9
FAST MUTE OUT II, C
10
FAST MUTE OUT II, NC
11
FAST MUTE OUT II, NO
12
FAST MUTE OUT II, C
13
FAST MUTE OUT II, NC
14
- BATT
2.3
INSTALLATION ELECTRICAL
This chapter describe the standard console (3 sections), if you only have 2 sections console, or you don’t
have the same units as described here, you can use the information here, to make your one configuration.
2.3.1
INSTALLATION ELECTRICAL EXTERNAL
This chapter describes the standard console (3 sections), if you only have a 2 sections console, or you
dont have the same units as described here, you can use the information here to make your own
configuration.
Before mounting the units in the console, you have connect all external cables to the console.
When this is done mount all internal cables.
2.3.1.1 CONFIGURATION EXAMPLES AND CABLE DIMENSIONS
The following paged show a typical installation example and cable dimensions.
NOTE:
There are two inputs for the NMEA signal.
1.
If one side of the NMEA signal is on chassis then you can use ether the BNC coax connector PS/
AF chassis in the centre section or the terminal ST12 on the connection board 1 in the centre
section.
2.
If one side of the NMEA signal is connected to negative battery then you must remove the BNC coax
connector from P5 on the connection board 1 in the centre section and leave P5 with out connection
because it will have negative battery on the outside. Connect your NMEA signal to ST12 on the
connection board 1 in the centre section.
For more detailed information about cabling between the units outside H2192, please refer the manual
for the unit in question.
CABLE 50 C2149 - H2192
8x0.75mm
2
shielded multicable
H2192
C2149
SIGNAL
ST3
J5
J2 OR J1
1
3
DATA TO RM2042
2
2
DATA TO C2149
3
5
- BATT
4
9
+ 5V
5
3
ALARM IN
6
2
ALARM OUT
7
5
GROUND
8
9
+ 9V