background image

Saia-Burgess Controls AG

Manual PCD7.D412DTPF & PCD7.D4xxxT5F │ Document 27-620 – Release ENG07 │ 2019-06-20

7-9

Updating and special settings

Special Unicode fonts

7

7.5.3 

Analysing incorrect fonts, font sizes or format templates

1   Arial, same format, 

keep

 size

2   Arial, simple, 

keep

 size

If the size is not available for Arial:
3   Same typeface, same format, 

reduce size to next possible size

4   Same typeface, simple, 

reduce size to next possible size

If there is no smaller typeset for this typeface:
5   Arial, same format, 

reduce size to next possible size

6   Arial, simple, 

reduce size to next possible size

If there is no smaller typeset for Arial:
7   Arial, same format or simple, 

use the smallest available font size

If you replace a typeset, then this is logged in the log file.

7.5.4 

Web Editor

Unicode character sets are available:

 

● using the source type "HTML TAG” in the Web Editor and with a .CSV file.

 

● by entering the text directly into the Web Editor as a string. In this case, no 

.CSV files are necessary. Do not import any Web Editor projects created us

-

ing Microsoft Windows using Unicode Character Set A into any other Windows 

project created using Unicode Character Set B.

Summary of Contents for PCD7.D410VT5F

Page 1: ...Document 27 620 Release ENG07 2019 06 20 Manual I O modules for PCD1 PCD2 series and for PCD3 series PCD7 D412DTPF standard SVGA MB Panel and PCD7 D4xxxT5F programmable pWeb Panel...

Page 2: ...1 Technical data of the SVGA MicroBrowser panel 2 1 2 2 Technical data for the pWeb panels 2 2 2 2 1 Overview 2 2 2 2 2 Product related presentation 2 2 2 2 2 Battery of the pWeb panel 2 3 3 Logic co...

Page 3: ...DNS Server 5 2 5 2 Logic Controller pWeb panels only 5 3 5 2 1 Program Name 5 3 5 2 2 Status RUN or HALT 5 3 5 2 3 S BUS 5 3 5 3 Web Connection 5 5 5 3 1 Connection 5 5 5 3 2 Type no selection for pW...

Page 4: ...15 7 6 3 Additional uBTerminal container for Save logs to File function 7 15 7 7 List of message box messages 7 16 8 Handling precautionary measures 8 1 Glass touchscreen 8 1 8 2 Information on the LC...

Page 5: ...ables removed EN04 2013 05 31 HaMa Chapter 3 1 2 Description oft the communica tion modules PCD7 F1xxS for Slot A EN05 2014 01 20 HaMa New logo and new company name ENG06 2016 01 27 HaMa New fixation...

Page 6: ...ation of components of the PCD7 D4xxxT5F The following are discussed Definition of the connectors Power supply and consumption Dimensions Possible communications modes In other chapters more details c...

Page 7: ...RTS232 4 CTS232 5 GND GND 6 DTR232 7 DSR232 8 COM232 9 DCD232 Power supply Earth 24V Connector 2 pole Communications 2 Ethernet switch 2 RJ 45 with LED indicator USB Standard USB slave Reset button Pu...

Page 8: ...mensions and cut out in mm 1 4 Dimensions and cut out in mm 1 4 1 12 1 panel 62 6 Front panel W H 319 264 Display W H 245 185 Cut out W H 300 244 1 4 2 10 4 panel 62 6 Front panel W H 281 221 Display...

Page 9: ...sides Refer to the photos below Mounting parts of 12 1 panels Mounting parts of 10 4 panels Mounting parts of 5 7 panels Note It is helpful to have somebody hold the unit from the front side of the pa...

Page 10: ...on a wall This is why we provide wall mounting kits for solid and cavity wall mounting In wall On wall In wall cavity walls On wall solid walls Mounting kit for the 5 7 MB panel PCD7 D457 IWS2 PCD7 D...

Page 11: ...are obvious ly also capable of displaying websites from controllers located within the network The procedure for this is the same as with the standard 12 SVGA panel Connecting to external devices If a...

Page 12: ...rally used as a Service port It is used mainly to download new firmware programs onto the device The USB port meets the USB 1 1 specification Maximum speed 12 MBit s 1 7 3 Getting started with the Web...

Page 13: ...ions 2 1 Technical data of the SVGA MicroBrowser panel Display Display size 12 1 TFT Resolution SVGA 800 600 Backlight LED Colours 65 536 Contrast adjustment Yes On Board File System 128 MByte Operati...

Page 14: ...croBrowser Automation Server Interfaces Ethernet 10 100 M 2 RJ45 switch USB 1 1 2 0 1 client Serial interfaces RS 485 socket for PCD7 F1xxS communications module Temperature range Operation 0 50 C Sto...

Page 15: ...1 3 years1 1 Depending on the ambient temperature The higher the temperature the shorter the buffer time New controllers include batteries in the scope of delivery and these must be inserted during co...

Page 16: ...85 Network The pin no s of the connected PCD are explained in the respective manual Make sure that the terminators are properly terminated In the example below you can see a possible connection betwee...

Page 17: ...ion can either be performed directly via the Setup menu on the pWeb panel or indirectly via the Hardware configuration on the PG5 Overwrite the current configuration the same as when making a change 3...

Page 18: ...y Connector pins Signal RS 232 Signal RS 485 0 GND GND 1 TXD D 2 RXD D 3 RTS 4 CTS 5 GND GND 6 DTR 7 DSR 8 COM 9 DCD Connector pins Signal 1 GND 2 NC 3 D 4 D Connector pins Signal 1 24 V 2 GND Install...

Page 19: ...connection Port x 1 10 pin spring loaded terminal block RS 422 PGND 10 TX 11 TX 12 RX 13 RX 14 PGND 15 RTS 16 RTS 17 CTS 18 CTS 19 PGND TX TX RX RX SGND RTS RTS CTS CTS Pin RS 422 Peripherie device T...

Page 20: ...S 232 connection Port x 1 RS 485 10 pin spring loaded terminal block 0 PGND TxD 1 2 RxD RTS 3 4 CTS PGND 5 6 DTR DSR 7 8 COM DCD 9 RS 232 connection to DTE RS 232 connection to DCE 6 DTR 0 PGND 1 TXD...

Page 21: ...module and can be activated using the silde switch on the module PCD7 F150S RS 485 terminator Slider 1 2 ON C O Closed terminated Slider 1 2 ON C O Open not terminated factory setting RS485 connection...

Page 22: ...elimo MP Bus 10 pin spring loaded terminal block 0 PGND MP 1 2 MFT IN 3 4 PGND 5 6 7 8 SGD 9 MP Bus cabling 0 PGND Earth connection MP line 1 MP Multi point The MP Bus is the Belimo master slave bus U...

Page 23: ...o generate the project However it can also be configured directly on the panel using the Setup menu described in Chapter 5 2 3 2 1 General information The following description assumes that the user i...

Page 24: ...Running the device configurator The device configurator is used for hardware configuration setting up logs and I O handling Double click on the project tree icon to start the device configurator Use a...

Page 25: ...wing procedure Open www sbc support com and download the latest firmware version Establish a connection between PG5 and the CPU the same way as when downloading an application in accordance with the a...

Page 26: ...on of the internal file sys tem The user is not able to see this partition 4 Options after download Execute program RUN Sets the PLC to RUN once the download is successfully completed Remain STOPPED A...

Page 27: ...r program is already stored in the on board flash memory only the RAM DB text for the on board flash memory are stored to the folder PLC_SYS not visible to the user Note Registers flags timers and cou...

Page 28: ...ith error The same as Run but with an error mes sage green Run conditional with error The same as Run conditional but with an error message green green green Stop The status Stop occurs in the followi...

Page 29: ...ggered and the controller restarted Instruction SYSWR K 1000 Software Watchdog instruction R K x Parameters according to following table K constant or entered value Register x 0 The Software Watchdog...

Page 30: ...VGA MicroBrowser panel and programmable pWeb panel MicroBrowser SVGA panel PCD7 D 12 1 SVGA Programmable pWeb panels firmware 1 19 34 PCD7 D412DT5F 12 1 SVGA PCD7 D410VT5F 10 4 VGA PCD7 D457VT5F 5 7 V...

Page 31: ...em Start screen see 5 4 3 Settings on page 5 7 Available for a few seconds only pressing on this icon will take you directly to the Setup menu Animated icon for Please wait data loading User defined S...

Page 32: ...cument 27 620 Release ENG07 2019 06 20 4 3 Using the Setup menu Saving and exiting 4 4 4 Saving and exiting If you have changed one or more parameters you must confirm if you want to save the changes...

Page 33: ...el settings See section 5 1 2 Logic Controller Configure the internal logic controller pWeb panels only See section 5 2 3 Web Connection Configure the web connection See section 5 3 4 System Info Sett...

Page 34: ...5 device configu rator If the Device Configuration is updated via PG5 the data set in Setup is overwritten If you want this data to be carried over to the PG5 the configuration requires the configurat...

Page 35: ...he configuration file to be uploaded into the PG5 project 5 2 1 Program Name Displays the name of the loaded PG5 project 5 2 2 Status RUN or HALT Displays the status of the logic controller 5 2 3 S BU...

Page 36: ...de Baud rate Sets the baud speed of the serial S bus Start address First S Bus station on gateway End address Last S Bus station on gateway Speed Speed of connection IP For setting the IP address Acti...

Page 37: ...nection with any PCD Connection is made with the local IP address 127 0 0 1 HTTP Direct Direct connection Ethernet only 5 3 3 Start page Name of the start page for this connection 5 3 4 Remote Host IP...

Page 38: ...device Production Date Month in which the device was produced Display Type Type of display internal designation HW LCD Rotation Rotation of the display 5 4 2 Info System info such as Firmware Version...

Page 39: ...arched for first in INTFLASH Webpages Remote before local Remote before local means file teq gif etc are searched for on the re mote server before the local server on the MB panel is searched Start De...

Page 40: ...em from scratch After the Formatting OK message the device returns to the System menu Time Real Time Clock RTC Time Real Time Clock RTC enter time container uBT_RtcTime Date RTC enter date container u...

Page 41: ...ted in a range between 0 and 5000 5 5 3 Rotation Landscape Portrait 5 5 4 Calibrate Touchscreen Carefully using the stylus 5 6 Keyboard 5 6 1 SIP Virtual Keyboard Activates deactivates SIP Soft Input...

Page 42: ...the password after entering it When you enter a new password you have to confirm it If the characters entered in the confirmation field do not match the new password the old password is re tained If...

Page 43: ...creased Forgot your password Delete this file TSPOINTS DAT For internal use INTFLASH WEBPAGES Directory for all project files which you want to save LOCALLY teq gif files etc INFLASH FONT FONT direct...

Page 44: ...ion from No local file search to Local file search before remote 2 Copy all associated files teq gif to the corresponding subdirectories of INTFLASH WEB PAGES Each associated station has its own subdi...

Page 45: ...rrupted during the download process no notification appears on screen This is because the FW flash memory is erased at the start of the process 7 1 2 Safe Firmware Download via USB The safe method for...

Page 46: ...er is activated with increasing frequency 4 Once the pitch or the frequency of the buzzer has stabilised after approx 10 sec release the Reset button and wait 5 You may have to wait to 1 to 2 minutes...

Page 47: ...l symbol in pixels X dimension Width of a character Text length Length of a single line piece of text Text field Length of the painter General recommendations for text fields you can find info in the...

Page 48: ...dth 5 Font size ySize min x Size max x Size Arial 36 41 7 36 Arial 24 28 7 24 Arial 20 23 6 20 Arial 16 19 3 16 Arial 12 15 3 12 Arial 10 12 3 10 Arial Bold 36 41 9 35 Arial Bold 24 28 7 23 Arial Bold...

Page 49: ...on for Sales Companies restricted Area Files containing typefaces for specific languages or fonts formats sizes not appearing in the list can also be installed on an MB panel If you want to do so plea...

Page 50: ...of 65 different files can be registered When a character is required the front file is opened and the data for the characters is called up The data is intended for subsequent use Name of the font file...

Page 51: ...Chinese etc we recommend sticking with the default settings for the text position not centred or justified In some typefaces it is not possible to represent all Unicode characters We recommend using t...

Page 52: ...te a button with the following action parameters Actions Set Vari ables The type is the Container the name is LANGUAGE and then the Unicode csv file We recommend copying the csv files into the local s...

Page 53: ...typeface 5 Arial same format reduce size to next possible size 6 Arial simple reduce size to next possible size If there is no smaller typeset for Arial 7 Arial same format or simple use the smallest...

Page 54: ...can be started by setting an interval time 0 30 000 mSec for the pulsed signal A 50 pulse pause ratio is used i e the pulse time is equal to the pause time Changes made while the alarm is already soun...

Page 55: ...uBT_BooterVersion ANSI text string Current version string 0 8 Firmware booter version String read only R W uBT_BuzzFreq ANSI text string 1000 125 8000 Frequency settings of the acoustic signal from t...

Page 56: ...the cache memory The cache memory is wiped upon startup and URL jumps Image files are decompressed and cached in a separate always acti vated video cache This video cache is wiped upon startup URL ju...

Page 57: ...string 350 0 639 Position of the startup text horizontal position from the left R W uBT_IntroTextYPos Decimal value string 300 0 479 Position of the startup text vertical position from the top down R...

Page 58: ...etup Text Enter show pay attention to upper lowercase A pop up window opens on the terminal containing the Setup menu R W uBT_SubNetMask String IP address 0xFF FF FF 00 Read write subnet mask of the s...

Page 59: ...BT_TrendLoad File currently loaded Read Write uBT_TrendSelect Last file in the directory File currently selected When saving a trend the value is set with the saved file name Read Write uBT_TrendOldes...

Page 60: ...ends Out of memory in heap 3 Usually displayed due to there being too many data points Offline trend alarm events HD log and online trend are stored in heap 3 Total amount of memory used by offline tr...

Page 61: ...id in the LCD display contains an irritant Should this fluid come into contact with your skin rinse the area affected under running water for at least 15 minutes Should fluid from the LCD display get...

Page 62: ...name must not contain any underscores or signs i e not PDP ADDRESS COFF_containername PDP FOR MAT Consider that the suffix for container offset is d for a decimal and k for the for mat HH MM Use Onlin...

Page 63: ...t tool for a hardware reset Do not use a paperclip or pin but rather push the microswitch carefully with a 3 mm drill bit 9 5 Some rules regarding gif images The three timestamps on the MB panel s gra...

Page 64: ...project with no gif list and you do not have to wait until all gif files in the gif list have been decompressed Decom pression continues in the background until the video memory is full if there are m...

Page 65: ...mp to the correct first page of the project 9 5 3 Decompression of Gif files analysis calculation Available for the solutions from sections 9 5 1 and 9 5 2 How do you analyse the number of gifs in the...

Page 66: ...3 1280 kbytes 2048 kbytes 4096 kbytes out of memory for language resource or LR out of memory 512 kbytes 768 kbytes 1024 kbytes 9 7 Extended alarm macros 9 8 Trend macros for MB panels with save logs...

Page 67: ...ogTrendMacro MB_ HDlog macros with S2F MacroLib SBCTrendMacro MB_ trend macros with S2F The applies to Online Trends Offline Trends DBs and Offline Saved Trends which allow you to play back all of the...

Page 68: ...gate through the list of saved files using the buttons and select one of them 7 Navigate through the list of files with the same prefix 8 Prefix name Free characters which are available as a prefix ma...

Page 69: ...nual PCD7 D412DTPF PCD7 D4xxxT5F Document 27 620 Release ENG07 2019 06 20 9 8 General recommendations for the Web Editor 9 FTP access By selecting FTP access you can display and read the list of CSV f...

Page 70: ...e reader of the risk to components from electrostatic discharges caused by touch Recommendation Before coming into contact with electrical components you should at least touch the Minus of the system...

Page 71: ...0 Part 1 WARNING Safety Check compliance with nominal voltage before commissioning the device see type label Check that connection cables are free from damage and that when wiring up the device they a...

Page 72: ...l and Electronic Equipment directive This symbol on our product shows a crossed out wheelie bin as required by law regarding the Waste of Electrical and Electronic Equipment WEEE disposal This indicat...

Page 73: ...strasse 18 3280 Murten Switzerland Phone 41 265803000 Fax 41 265803499 Email support support saia pcd com Supportsite www sbc support com SBC site www saia pcd com International Represetatives SBC Sal...