background image

 

 
 

 

      

Copyright. Sygnal 2018

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

Sygnal Ambient Intelligence 

Climate Point Operation Manual 2018 

 
 

 

Summary of Contents for Chatterbox

Page 1: ...1 Copyright Sygnal 2018 Sygnal Ambient Intelligence Climate Point Operation Manual 2018 ...

Page 2: ...ht to make changes and improvements to any of the products described in this document without prior notice Under no circumstances shall Sygnal be responsible for any loss of income or any special incidental consequential or indirect damages howsoever caused Warranty The contents of this document are provided as is Except as required by applicable law no warranties of any kind either express or imp...

Page 3: ...al Cooling and Economy settings 10 4 5 Setting the Global Time Schedules 11 4 6 Leaving Global Time Schedules Page 12 4 7 Accessing Individual Zone 12 4 8 Return to Overview page 12 4 9 Browse to other systems 12 4 10 Adjusting the settings on a Zone 12 4 11 Setting Time Schedule for Individual Zones 13 5 Sygnal Climatepoint Controls 14 5 1 Sygnal Climatepoint Navigator 14 5 1 1 Getting to know yo...

Page 4: ... 2 Outdoor Unit 18 6 3 Vents Return Air Grill 18 6 4 Controller 18 7 Troubleshooting 19 7 1 Digital Inverter System Self Diagnostics Fault detection 20 8 Warranty terms and conditions 21 9 Warranty key points in large print 22 ...

Page 5: ...ms are connected on the same LAN they recognise each other and the appropriate interface is loaded without the need for you to do anything 1 6 Html User Interface The html user interface can be used on most devices with a browser from Smartphone or tablet to PC The display results vary slightly depending on your device and browser type used Many people choose the iPad mini as their UI platform but...

Page 6: ...r to the chatterbox network The network name is noted on the cover sticker SSID Sygnal where is a unique number for each different chatterbox 1 The Password noted on the cover sticker is chatterbox Figure 1 2 3 4 2 Once connected to the chatterbox network you can open your browser and browse to the chatterbox IP address 192 168 2 11 also noted on the cover sticker Figure 5 6 3 You may wish to book...

Page 7: ... and list all connected devices This will enable you to find your chatterbox IP typically look something like 192 168 1 12 or similar number Figure 9 By typing this number into your browser you will be able to access the Opening page of your chatterbox NOTE Some routers ship with UPNP disabled You should check your router instruction manual for details on how to check this setting Without UPNP ena...

Page 8: ...tled Your Local Devices with the Mac Address and system description You can click this link to go straight to the User Interface without having to log in Figure 10 4 Once you have received notice of your User Name and Password go to the log in page enter the details then press Login 5 The next screen that launches will have a list of your chatterboxes Figure 11 6 To access the User interface for a...

Page 9: ...3 Examples of User Interfaces UI Images Figure 12 Example of Sygnal Climatepoint multi zone temperature control user interface on an Ipad Mini Figure 13 Example of a Sygnal Lightpoint lighting control interface on an Ipad Mini ...

Page 10: ...ght balance for their home or building between energy reduction and comfort The slider moves the point at which the worst performing zone can terminate dynamic energy recovery and force heating or cooling The Climatepoint zoning control system are a unique part of the Sygnal system that provides the ability to dramatically reduce your energy bills It is important to note that the average household...

Page 11: ... Global Time Schedules screen Figure 15 Setting Global Time Schedules cont Press on any day in Schedule A you wish to activate and the day will illuminate Green Figure 15 Yellow Arrow Use the drop down bars to set on and off time for the system Figure 15 Red Arrows Repeat these steps for Schedule B It is important to note that these settings when launched from the Overview page will activate On Of...

Page 12: ...eturn to Overview page Press the overview button 4 9 Browse to other systems If you have multiple Sygnal Air Conditioning or Lighting systems use the Other Systems button to browse to them Simply select the system you wish to interact with from the drop down list 4 10 Adjusting the settings on a Zone Use the slider bar to adjust the temperature set point within the zone Figure 16 Yellow Arrow To u...

Page 13: ...ck events in each zone select the zone and then press the HIDE SHOW button Orange Arrow then follow the time schedule instructions in points 4 5 4 6 4 11 Setting Time Schedule for Individual Zones Go to the zone and press the HIDE SHOW button in the bottom right hand corner Figure 16 Orange Arrow Then follow the same instructions as per points 4 5 and 4 6 Setting zone timers will only action the e...

Page 14: ...atepoint Controls 5 1 Sygnal Climatepoint Navigator 5 1 1 Getting to know your controller 5 1 2 Turning the system ON and OFF Press the ON OFF Button when on the main screen to turn all zones ON or OFF Set Button Navigate Left Navigate Right Current Mode Number of zones currently active Navigate Up On Off Navigate Down ...

Page 15: ...en and ON Figure 18 Zone turned OFF 5 1 3 Turning a Zone ON and OFF Press the ON OFF Button when in the zone screen to turn an individual zone ON or OFF 5 1 4 Browsing to a Zone Use the left and right arrow buttons to scroll through available zones on your system Continually scrolling in one direction will cycle the main screen and available zones ...

Page 16: ...re sensing mode In Temperature sensing mode Figure 20 the airflow automatically adjusts according to the information being fed back by the temperature sensor in the zone As an additional feature there is a Flow set mode Figure 21 for each zone Flow set mode will allow you to adjust the airflow to the zone but will not work off the temperature sensor if Flow is engaged To change the mode in a zone ...

Page 17: ...fferent colours that signify different operations a Green Indicates the zone is active but it is not currently needed as the room is at temperature b Blue indicates the zone is active and running on cooling c Red Indicates the zone is active and running on heating 5 3 Climatepoint Hybrid switches 2 3 4 6 button Sygnal s Hybrid Capacitive touch button switches are to be used in conjunction with Syg...

Page 18: ...ur installer for a replacement filter a charge will apply 6 2 Outdoor Unit Do not place any object in front of the condenser Keep free of grass leaves and any other form of debris This will allow for proper air flow and ensure unit efficiency 6 3 Vents Return Air Grill Regular cleaning of the return air grill and air vents is recommended This will prevent build up of dust and dirt 6 4 Controller C...

Page 19: ... outdoor unit The air conditioner does not operate Has the mode been set correctly Is at least one zone ON Has the setpoint for ON zones been set low enough for cooling or high enough for heating Has the circuit breaker been tripped The air conditioner does not cool heat effectively Has the mode been set correctly Are all the windows and doors closed Are the filters dirty Are the intake or outlet ...

Page 20: ...door coil sensor short circuit Indoor coil sensor open circuit Indoor coil sensor short circuit Fault D3 High Pressure or Low Pressure Fault Line 2 scrolls one of the following HP compressor safety LP compressor safety HP LP compressor safety Fault D4 Interconnect Indoor Outdoor Line 1 Fault 4 Line 2 scrolls one of the following AHU and Condenser Interconnect Fault D5 Contact Manufacturer Line 1 F...

Page 21: ...Sygnal and form part of the air conditioner these parts will be repaired at the installation location providing the location is within 100km from the Company s premises or the premises of an appointed Agent or Dealer The guarantee is inclusive of parts and labour Subject to the above the Company s liability and that of its resellers is wholly limited to the original cost of the product sold Any un...

Page 22: ...to set a new standard in product reliability Tracking all system activity also helps our Service Team identify any environmental factors unusual activity or a repeat faults To achieve the required level of tracking to provide peace of mind for our clients we require that all systems are registered on the Sygnal website within the first twelve months of operation Immediately on completion of the on...