6.1. On receipt of the equipment, check that:
- The equipment is complete, according to the 

specification of its composition.
- The equipment has not been damaged in 

transit.
6.2. Before each use, check that:
- The equipment is complete, according to the 

specification of its composition.
- The coalescing filter of the air network is usable.
- The air hoses are in good condition, have 

leak-free connections and are sufficiently well 

adjusted.
- The regulator and carbon filter are clean and 

show no signs of changing colour, from white to 

pink, and there are no symptoms of smell in the 

mask. Change if necessary.
- That the pads and components for adjusting to 

the face are clean and have no signs of 

deterioration or damage. If the equipment has 

been stored in a cold environment, avoid the 

appearance of signs of condensation before 

putting on the equipment.
- The air hose connection for supplying air to the 

mask is in good condition and is properly 

connected to the adjustable regulator on the belt.
- The belt is correctly mounted by means of the 

buckle and is properly tightened, the regulator 

positioned at the hip with the air hose to the visor 

in front of your body.

 

- The buckle closes properly.
- The connector of the hose to the spray gun is 

connected correctly.
- All connections are properly made and that no 

air leaks.
6.3. Checking the air flow
NOTE:
 The regulator of the network supply will 

provide an adequate flow of air to the equipment, 

provided that the length of the air hose is 

appropriate and the supply pressure to the 

equipment is as described in section 3.4.
The following method should be used to check 

the flow range to the equipment, before entering 

the work area:
1. Connect the compressed air hose to the 

pre-set regulator.

2. The flow indicator should be in the section 

marked in green.

3. If the indicator is in any of the areas marked 

in red:

- Check for and correct any leaks.

- Check and correct the state of the air hose.

- Recheck the indicator.

4. If the flow indicator is damaged or stays in the 

red or green sectors even without air supply, 

replace the indicator before using the equipment.

5. If after the second check the indicator is still 

in any of the red sections, the equipment should 

not be used without a thorough examination of 

its condition and a new checking process.

6. INSTRUCTIONS FOR USE

NOTE:  Only when the equipment is fitted 

correctly, as described below, will it provide the 

prescribed degree of protection.
1. Put the belt to support the regulator around 

your waist, positioning the regulator above the 

right hip.

2. Place the mask on your head, adjusting it to 

your head to achieve the most comfortable and 

efficient position for working. Remove any trace 

of condensation before putting on the mask.

3. Connect the air supply hose from the regulator 

to the mask. If you notice vibrations during the 

connection, disconnect and then reconnect.

4. If applicable, attach the air supply hose to the 

spray gun.

5. While walking, make sure the hoses do not 

become entangled with each other and impede 

your movement.

7. ASSEMBLY OF THE EQUIPMENT

The equipment requires a monthly check-up. 

Care of the equipment, during and after its use, 

will ensure a reliable and lasting service.
After use, the equipment should be washed with 

water and a solution of neutral soap, then rinsed 

with a damp cloth and dried. To keep the mask 

in the best possible condition do not use abrasive 

cleaning products. Rinse with water and mild 

detergent and dry with a soft cloth.
Do not use solvents or abrasive cleaning agents. 

These will damage the equipment. See section 

9.3.

8. GENERAL MAINTENANCE

Summary of Contents for 4240

Page 1: ...m a n u a l d e i n s t r u c c i o n e s l i s t a d e r e p u e s t o s i n s t r u c t i o n m a n u a l s p a r e p a r t s l i s t Careta 4240 4240 Face mask...

Page 2: ......

Page 3: ...encias p g 5 5 Chequeo del rea de trabajo p g 6 6 Instrucciones de uso p g 6 6 1 A la recepci n del equipo p g 6 6 2 Antes del empleo del equipo p g 6 6 3 Comprobaci n del caudal de aire p g 6 7 Monta...

Page 4: ...fallos en el equipo L nea de equipos de aire comprimido con una variedad de piezas para la cabeza a utilizar en aplicaciones tales como pintura pulverizada o contra polvo t xico niebla o humos es dec...

Page 5: ...tre 4 y 10 bar a la entrada de la manguera La careta requiere un suministro m nimo de 160 l min 5 4 cfm y si se utiliza con una pistola aerogr fica con un minimo de 620 l min 21 cfm suministrados con...

Page 6: ...rrectamente conectada al regulador ajustable del cintur n Que el cintur n est correctamente montado a trav s de la hebilla y ce ido posicione el regulador en la cadera con la manguera de aire al visor...

Page 7: ...suave No utilice disolventes o agentes abrasivos de limpieza Da ar n el equipo Ver apartado 9 3 8 MANTENIMIENTO GENERAL El equipo requiere de un m nimo mantenimiento Los componentes deteriorados por e...

Page 8: ...8 10 DESPIECE ed 11 04 03 05 06 01 02 HYGIENE KIT 5u 07 N Cod U 01 15880011 1 02 15880012 1 03 15880013 1 04 15880009 1 05 15880014 1 06 15880015 1 07 1 56414033 1 07 2 56414045 1 1 US Mil 2 Nitto...

Page 9: ...se en contacto con f brica Queda excluida cualquier exigencia de m s trascendencia contra el proveedor en particular la indemnizaci n por da os y prejuicios Esto se aplica igualmente a los da os que s...

Page 10: ......

Page 11: ...3 5 Work area check page 14 6 Instructions for use page 14 6 1 On receipt of the equipment page 14 6 2 Before using the equipment page 14 6 3 Checking the air flow page 14 7 Assembly of the equipment...

Page 12: ...failures in the equipment This is a line of compressed air equipment with a variety of parts for the head and for use in applications such as spray painting or against toxic dust mist or fumes i e in...

Page 13: ...of 620 l min 21 cfm supplied with a pressure of 6 bar 90 psi 3 5 Air hoses The air supply hose to the pre set regulator should have an internal diameter of 4 16 or 8 mm The suggested maximum lengths...

Page 14: ...ressed air hose to the pre set regulator 2 The flow indicator should be in the section marked in green 3 If the indicator is in any of the areas marked in red Check for and correct any leaks Check and...

Page 15: ...s also suggested that the filter is periodically subjected to a test of differential pressure at full flow and if a level of 0 7 bar 10 psi is reached the filter must be replaced The filter is replace...

Page 16: ...e apparatus and deliver it to the nearest Technical Service or get in contact with the factory Any other claims against the supplier beyond those expressed above are excluded especially regarding inde...