18
4.3 - CONNECTION TO THE DMX CHAIN
Use a cable conforming to specifications EIA RS-485: pole twisted, shielded, 120Ohm
characteristic impedance and low capacity (PROEL DMXD – DMXD1).
Do not use microphone cable or other cable with different characteristics than those
specified. Terminations must be made with male / female XLR 3-pin connectors. You must
enter on the last device a terminal plug with a 120Ohm resistance (min1 / 4 W) between
terminals 2 and 3.
IMPORTANT: The cables must not come into contact with each other or with the metal
housing of the connectors. The housing itself must be connected to the shield braid and to
pin 1 of the connectors.
5. - SETUP
5.1 – MENU
WAIT TIME
1 – 600
Time between 2 smoke outputs
START TIME
1 – 600
Time of smoke output
SMOKE VOLUME
OUTPUT
1% – 100%
Quantity of smoke output
PUMP ADJUST
SMOKE OUTPUT
1% – 100%
Power of the pump
FAN ADJUST AIR
VOLUME
1% – 100%
Fan’s speed
DMX ADDRESS
001 – 511
DMX address
5.2 – DMX MODE
2 Channels mode
Channel
Value
Function
1
000 – 255
Smoke quantity
2
000 – 255
Fan speed
Summary of Contents for SG H1500