12
F3
0
15
min
3
duration of the after dripping evaporator fan delay
LABEL MIN. MAS.
U.M. DEF. DIGITAL
INPUTS
i0
0 5 -
0
effect caused by activation of microport input; see also i4
0 = no effect
1 = the cabinet light will be switched on (only if u1 = 0, until the input is
deactivated)
2 = the evaporator fan will be switched off (for up to the length of time set by i3
or until the input is deactivated)
3 = the compressor and evaporator fan will be switched off (for up to the length
of time set by i3 or until the input is deactivated) (18)
4 = the evaporator fan will be switched off (for up to the length of time set by i3
or until the input is deactivated) and the cabinet light will be switched on (only if
u1 = 0, untilthe input is deactivated)
5 = the compressor and evaporator fan will be switched off (for up to the length
of time set by i3 or until the input is deactivated) and the cabinet light will be
switched on (onlyif u1 = 0, until the input is deactivated) (18)
i1
0 1 -
0
microport input contact type
0 = NA (input active with contact closed)
1 = NC (input active with contact open)
i2 -1
120
min
30
microport input alarm signal delay
-1 = the alarm will not be reported
i3 -1
120
min
15
maximum duration of the effect caused by activation of the microport input on
the compressor and on the evaporator fan
-1 = the effect will last until the input will be disabled
i4
0
1
-
0
recording of microport input alarm (19) 1 = YES
i5
0 7 -
0
effect caused by activation of the multifunction input (only if P4 = 3)
0 = no effect
1 = DEFROST SYNCHRONISATION - after the period of time set by d5
defrosting will be activated
2 = ACTIVATION OF ENERGY SAVING FUNCTION - the Energy Saving
function will be activated (until the input is deactivated); see also r4
3 = CLOSURE OF THE AWNING - the cabinet light will be turned off (only if u1
= 0 and only if switched on manually) and the Energy Saving function will be
activated (untilthe input is deactivated); see also r4
4 = ALARM ACTIVATION - after the amount of time set by i7 the display will
flash the code "iA" and the buzzer will be activated (until the input is
deactivated)
5 = TRIPPING THE PRESSURE SWITCH - the compressor will be switched
off, the display will flash the code "iA" and the buzzer will be activated (until the
input is deactivated);see also i7, i8 and i9
6 = TURNING ON THE AUXILIARY OUTPUT - the auxiliary output will be
turned on (only if u1 = 2, until the input is deactivated)
7 = SWITCHING OFF THE DEVICE - the device will switch to stand-by mode
(until the input is deactivated)
i6
0 1 -
0
type of multifunction input contact (only if P4 = 3)
0 = NA (input active with contact closed)
1 = NC (input active with contact open)
i7 0
120
min
0
if i5 = 4, delayed multifunction input alarm notification (only if P4 = 3)
if i5 = 5, delayed multifunction input deactivation compressor delay (only if
P4=3) (20)
i8 0
15
- 0
number of multifunction input alarms such as to cause device block alarm (only
if P4 = 3 and i5 = 5) 0 = no alarm
i9 1
99
min
240
time that must elapse without multifunction input alarms so that the alarm
counter is zeroed (only if P4 = 3 and i5 = 5)
LABEL MIN. MAS.
U.M. DEF. DIGITAL
OUTPUTS
u1 0 7 -
5
service controlled by the fourth output (21)
0 = CABINET LIGHT - in this case, the important factors are: the key
,
parameters i0, i5 and u2
1 = DEMISTING HEATER - in this case, the important factors are: the key
and parameter u6
2 = AUXILIARY OUTPUT - in this case, the important factors are: the key
,
parameters i5 and u2
3 = COMPRESSOR 2 - in this case, the important factor is parameter C9
4 = ALARM OUTPUT - the output is activated during an alarm and during an
error; in this case the important factors are parameters u3 and u4
5 = DOOR ELEMENT - in this case the important factor is parameter u5
6 = EVAPORATOR VALVE - in this case the important factors are parameters
u7 and u8
7 = DEFROST SYNCHRONISATION - the output works in parallel with the
defrost output; in this case the important parameter is factor i5 (22) (23)
enabling cabinet light or auxiliary
u2 0 1 -
0
enables manual switching on/off of the cabinet light or auxiliary output while in
stand-by mode (only if u1 = 0 or 2) (24) 1 = YES
Summary of Contents for HD70
Page 50: ......
Page 74: ......
Page 98: ......
Page 122: ......
Page 147: ...1 2 2 2 3 3 4 4 5 6 6 6 14 14 15 15 19 20 20 20 21 21 22 1 2 22 23...
Page 148: ...2 1 2 4 5 9 10 HFC 7 11 12 1 2 3 4 5 6 B C D E F G H L R W...
Page 149: ...3 13 14 15 OFF 16 17 18 19 20 21 22 23 24 25 26 27 28 29 48 30 31...
Page 151: ...5 33 30 34 35 36 37 38 50 2 39 40 41 42 43 SHUKO N60320 44 30 45 46...
Page 152: ...6 1 2 48 49 49a 50 N 51 1 2 2 48 15 15 SP r1 r2 C F 1 0 4 PA 15 19 15 4 SP 15 15 1 2...
Page 161: ...15 0 10 6 20 61 22 15 6 5 6 48 C P2 F P2 Pr1 P0 49...
Page 166: ...20 66 67 74 68 71 OFF 16 17 62 73 30 OFF 16 17 76 77 78...
Page 167: ...21 2002 96 EC 2002 96 WEEE...
Page 168: ...22 WEEE 2002 96 12 82 F D D 12 1 2 82a F B E G B E D B E G D A B E G A 12...
Page 171: ...2 1 46 4 7 12 13 15 14 11 10 5 set 16 17 18 Z Z Y 9...
Page 172: ...19 20 21 22 23 24 25 26 27 28 29 30 set 31 32 75 83 64 150 83 64 204 204...
Page 173: ...33 35 36 34 37 38 39 40 41 42 43 44 45 46 48 1 2 49 set 1 2...