S
Proc Sheet 1 02
myX-6/myV-65
REMOVING / REPLACING THE DISPLAY
2/2
Ref. SCT U38 SSC DTS 0012 – Index A - May 12 , 2003
Page 5-17
29/09/03- SAV/GSM/254/V1 EN
Tools :
- A 0.6mm torx screwdriver
-
gloves
-
Insertion/extraction flex tool
-
Display / metal dome jig
Notice:This procedure must be performed by an technician provided with gloves , to avoid any risk
of pollution.
•
Display contacts must never be touched.
Preliminary operation
1. Remove the back cover (
Proc sheet 0 01
).
2. Remove the battery (
Proc sheet 0 02
).
3. Remove the front cover (
Proc sheet 0 03
).
Removal procedure :
1. On the electronic equipped module (1), unscrew the six attachment screws (2) .
2. Remove the light guide keypad (3).
3. Replace the electronic board on the display / metal dome jig
4. Turn the display round (4) to the right of the electronic board
5. Open Zif connector lock (5) by means of the extract flex tool, by lifting lock up
6. Remove delicately the flex PCB (6).
Placement procedure :
1. Check that the connector lock (5) is lifted up
2. Introduce partially the flex PCB into the zif connector
3. Place the display (4) on the display / metal dome jig
4. Use the flex tool to insert totally the flex PCB (6) into Zif connector (5)
5. Press the Zif connector lock (5),using the tool
6. Replace the light guide keypad (3)
7. Turn the display round (4) on the electronic board
8. Position and tighten the six attachments screws with torx couple of
0,25 N.m.
9. Verify that there are not impurities on the display.
Further operations :
1. Replace the front cover (
Proc sheet 0 03
).
2. Replace the battery (
Proc sheet 0 02
).
3. Replace the back cover (
Proc sheet 0 01
).
4. Carry out the radio test (
Test Sheet 06
).