30
USING THE ALLEN KEY
Over time, the silicone seal surrounding the
shower screen will need to be replaced to
ensure optimum brewing performance.
1. Press the POWER button to switch the
machine off and unplug the cord from the
power outlet.
2. Carefully remove the water tank and drip
tray, taking particular care if they are full.
3. Using a skewer or similar, clean the centre
of the screw of any residual coffee.
4. Insert the shorter end of the Allen Key
into the centre of the screw. Turn counter-
clockwise to loosen the screw.
Clean center of screw
before inserting Allen Key
5. Once loosened, carefully remove and retain
the screw, stainless steel shower screen and
black dispersion plate. Make note of the
side of the shower screen and dispersion
plate that are facing downwards. This will
make re-assembly easier. Wash the shower
screen and dispersion plate in warm soapy
water, then dry thoroughly.
6. Remove the silicone seal with your fingers
or a pair of long-nose pliers. Insert the new
seal, flat side first, so the ribbed side is
facing you.
7. Re-insert the dispersion plate, then the
shower screen, then the screw. With your
fingers, turn the screw clockwise for
2-3 revolutions then insert the Allen Key
to tighten until the screw is flush with the
shower screen.
8. Re-insert the drip tray and water tank.
Contact Sage Customer Service or visit
www.sageappliances.co.uk
for replacement
silicone seals or for advice.