= Inspect
= Verify
= Perform process
This document and all copies are the property of Spider
®
. All dimensions and data are indicative only.
The user must ensure that the equipment complies with local rules and regulations.
Page 38 of 38
Revision: A
Issue Date: 2017-Dec-18
Document No: 721641-1
Daily Inspection Checklist
WARNING!
Perform all daily test to ensure correct operation! Do NOT use the hoist for lifting loads until it has
passed all daily tests. If the hoist fails any test do NOT use the hoist until it is repaired.
Part/Function
Check for
1
Visual Inspection
Verify all parts of the system are present, in proper working, order and
undamaged.
9
Wire rope.
9
Rigging.
9
Platform.
9
Power Supply Cable.
9
Limit Switch(es), if applicable.
9
NO damaged, loose, or missing parts.
9
Hoistway clear of obstructions.
2
Emergency Stop
Conduct a test run with the heaviest working load available [maximum
5500 lb (2500 kg)]. Press Emergency Stop Button.
9
Hoist stops immediately.
9
UP and DOWN Buttons disabled.
9
RED
Error Light comes on.
Reset Emergency Stop Button.
3
Manual Descent
Raise the platform approximately 3 feet (1 meter) and stop. Disconnect
the power supply. Pull up the Controlled Descent Loop (between the
two motors).
9
The platform descends at a slow, controlled speed.
9
The Overspeed does NOT trip.