background image

 

SRM 80 F3

 

80 

16 

1040 

76 

2

 

SRM 100 F3

 

100 

20 

1015 

76 

2

 

SRM 120 F3

 

120 

24 

1445 

76 

2

 

SRM 140 F3

 

140 

28 

1828 

76 

2

 

SRM 140 LF3

 

140 

28 

1292 

76 

2

 

SRM 160 F3

 

160 

32 

1531 

76 

2

 

SRM 180 F3

 

180 

36 

1372 

76 

2

 

SRM 250 CF3

 

250 

50 

3410 

102 

2

  

Capacity 

Charge  

Electrolyte 

Maximum 

Number  

  

C

5

Ah 

current 

volume 

level 

of

 Cell type 

 

0.2 C

5

 

above plates 

terminals

  

(Ah) 

(A) 

(cc) 

(mm.) 

(in.)

6. Topping-up

No electrolyte level measurement is 
necessary if a Saft Celltopper Plus is 
used which allows the correct level to 
be obtained by a simple nozzle setting 
when fitted with the correct spacer 
tube. 

Refer to Table B

 for cell type 

and corresponding spacer tube type. If 
a filling pistol is not available, a clean 
plastic filling bottle can be used for 
topping-up. 
Do not fill above the maximum (upper 
line) level. All topping-up equipment 
shall be dedicated to Ni-Cd batteries.

7. Periodic maintenance

Periodic maintenance should be 
carried out every two years, or as 
required.

 

Keep the battery clean using only 
water. Do not use a wire brush or 
solvents of any kind. Vent plugs can 
be rinsed in clean water when dirty.

 

Check the electrolyte levels. Never 
let the levels fall below the minimum 
(lower line) level. Use only distilled or 
deionized water for topping-up. 
Frequency of topping-up must be 
determined for each battery.  

 

It depends on charging voltage, 
temperature and actual utilization  
of the battery. 

Refer to Section 6 

concerning topping-up.

 

Check torque of all upper nuts and 
capscrews (if supplied).  

 

Apply a thin layer of neutral vaseline 
or anti-corrosion coating agreed by 
Saft to all connectors, terminal nuts 
and cap screws (if supplied).

 

Check charger settings. It is of great 
importance that the recommended 
charging voltage remains unchanged. 
High water consumption of the 
battery is usually caused by improper 
voltage setting of the charger.

8. Changing electrolyte

Due to the sintered electrode / plastic 
bonded technology, it is not necessary 
to change the electrolyte during the 
life-time of the cell(s).

9. Battery service and recycling

Contact your Saft representative 
concerning battery testing.  
Saft America Inc. is licensed to receive 
and recycle spent batteries.  
To protect the environment all used 
batteries must be recycled.

Saft

Industrial Battery Group

 

Railway Sales
109 Beaver Court, Suite 200
Cockeysville, MD 21030 (USA)
Tel:  410-771-3200
Fax: 410-329-9802
711 Industrial Blvd
Valdosta, GA 31601 (USA)
Tel:  229-247-2331
Fax: 229-245-2890

www.saftbatteries.com

Doc N° 21141.2-1211 

Data in this document is subject to change without 

notice and becomes contractual only after written 

confirmation.
Société par Actions Simplifiée  

au capital de 31 944 000 

RCS Bobigny B 383 703 873

Le Révérend Imprimeur - Printed in France - 1k

SRM F3 Ni-Cd batteries

Table A: 

Cell Data

 Cell type  

Spacer tube type

 

SRM 80 F3

 

C

 

SRM 100 F3

 

C

 

SRM 120 F3

 

D

 

SRM 140 F3

  

C

 

SRM 140 LF3

 

D

 

SRM 160 F3

 

C

 

SRM 180 F3

 

C

 

SRM 250 CF3

 

E

Table B: 

Topping-up equipment (Celltopper Plus)*

* Refer to separate instructions for further information on Celltopper Plus. 