background image

Push reset 

button with a 

pointed object

Figure 10 - Replacing a fuse

  Remove fuse cover by inserting, on either 

side, a flat head screwdriver and twisting.

  Measure continuity. If good continuity, 

the fuse is good. Re-install the cover.

  If no continuity, remove and replace 

the fuse using a 7 mm socket and 
torque wrench with a torque of 3 N.m 
(26.5 in.lbs). Re-install the cover.

Figure 9 - Reset button

 

 

 

   steady

Emergency alarm

 

 

 

   steady

Software trap

 

 

 

  steady

Schedule a replacement of the Evolion

®

 module.

Contact your local Saft representative for further details.

 

 

 

  steady

The Evolion

®

 can continue to operate normally.

Use the Evolion

®

 Toolbox software to view the active alarms.

Troubleshoot the active alarms according to the Evolion

®

 Technical Manual Appendix E.

Contact your local Saft representative for further assistance.

 

 

 

  steady

The Evolion

®

 is currently disconnected by its own internal switch.

Disconnect and remove the Evolion

®

 from the application to prevent inadvertent waking 

up and reconnecting with too much voltage difference (2 V maximum).
Use the Evolion

®

 Toolbox software to view the active alarms.

Troubleshoot the active alarms according to the Evolion

®

 Technical Manual Appendix E.

Put Evolion

®

 back into service if alarms are successfully cleared. Make sure to 

reconnect with less than 2 V difference between modules.
Contact your local Saft representative for further assistance.

Evolion

®

 is 

OFF

  

on a live bus

The Evolion

®

 is likely deep discharged.

Disconnect and remove the Evolion

®

 from the application.

Contact your local Saft representative for further assistance.

Saft
Industrial Battery Group
12, rue Sadi Carnot
93170 Bagnolet - France
Tel : +33 (0)1 49 93 19 18
Fax: +33 (0)1 49 93 19 64

www.saftbatteries.com

Doc. Nº 21813-2-0115
Edition: January 2015

Data in this document is subject to change without 

notice and becomes contractual only after written 

confirmation.
Société par Actions Simplifiée au capital de  

31 944 000 €
RCS Bobigny B 383 703 873
Produced in the UK by Arthur Associates Limited

8. Maintenance   

The Evolion

®

 requires no maintenance, 

but checking its state and taking 
necessary action during periodic site 
routines is recommended.
The SOC can be checked while in 
operation. Refer to Figure 3 and 
Table 2.
Check if the heat sink area is 
obstructed or accumulated with 
dirt and debris. As necessary, 
un-obstruct or clean using a non-
metallic brush or a dry or damp 
cloth. Do not use any cleaning 
solvents or soaps. Do not immerse, 
dunk, bathe or hose off the Evolion

®

.

Check the rectifier output. It should 
be set at 56.0 V ± 0.5%.
Check the LED and verify that the 
operating status is normal. Refer to 
Table 6.
If an abnormal operation (see Table 
6) is noticed, see Section 10.

9. Resetting the software   

If an alarm that is not automatically 
resettable or software trap is 
encountered then push the reset 
button using a pointed object. After 
the unit can be restarted normally.  
See Figure 9 below.

IMPORTANT:

 Only push the 

reset button when the Evolion

®

  is 

disconnected from the application.  
The Evolion

®

 must be ON to reset.

If the Evolion

®

 emits an unusual 

smell, feels hot, changes shape or 
appears abnormal in any other way, 
conduct the following procedure:
1. Disconnect the Evolion

®

 from power.

2. Shut-down the Evolion

®

 by pushing 

the ON/OFF button for at least 4 s.

3. Leave the Evolion

®

 in place.

4. Call your local Saft representative 

for further assistance.

To check and replace the fuse, 
conduct the following procedure:
1. Shut-down the Evolion

®

 by pushing 

the ON/OFF button for at least 4 s.

2. Disconnect and un-install the 

Evolion

®

3. Check and replace the fuse 

according to Figure 10.

4. The Evolion

®

 is now ready for 

service.

11. Removal and recycling   

Make sure to turn OFF the battery 
breaker.
1. Shut-down the Evolion

®

 by pushing 

the ON/OFF button for at least 4 s.

2. Disconnect the power terminals.
3. Disconnect alarm/communication 

cables.

4. Remove the Evolion

®

 and stage for 

recycling.

5. Call your local Saft representative 

for further assistance.

10. Troubleshooting   

The Evolion

®

 Toolbox software is the 

best way to interrogate an Evolion

®

 

during troubleshooting. Refer to the 
Evolion

®

 Technical Manual Appendix E 

for troubleshooting alarm details.
If an abnormal operation status 
is noticed, conduct the following 
procedure (Table 8): 

Table 8

Reviews: