Proc sheet 2 02
myC2-3
5HPRYHDQGSODFHKSYLEUDWRU
)3&/&'IODS
1/1
7RROV
-Tweezers
- Iron has to weld
3UpOLPLQDLUHRSHUDWLRQ
1. Remove the battery (Proc sheet 0 01).
2. Remove the lower housing of mobile (Proc sheet 1 01).
3. Remove the keyboard (Proc sheet 1 04))
4. Remove MMI board (Proc sheet 1 07).
5. Remove the flap (Proc sheet 1 09).
6. Remove housing Flap (Proc sheet 1 10).
5HPRYDOSURFHGXUH
1. Unsolder the 2 threads of the
HP
( 1 ), then extract the
HP
( 3 ).
2. Unsolder the 2 threads of the vibreur (2), then extract the vibrator (4).
3. Disassemble ciu/lcd of upper housing flap.
4. Unsolder the FPC, Disconnect of connect
BTB
.(5), To extract the FPC.
3ODFHPHQWSURFHGXUH
1. Position the FPC. Solder Mass plan (6).
2. Position the vibrator. Solder the 2 threads (red and black) (7).
3. Position the HP. Solder the 2 threads (white and black) (7).
)XUWKHURSHUDWLRQV
1. Place the flap (Proc sheet 1 09)
2. Place the keyboard ( Proc sheet 1 04).
3. Place the board MMI (Proc sheet 1 07).
4. Place the lower housing of mobile (Proc sheet 1 01).
5. Place of the battery (Proc sheet 0 01)
Risk of the procedure :
Damage LCD, FPC, Hp, vibreur
Thread red vibreur
Thread black vibreur
Thread black Hp
Thread white Hp
Procedure
Symptom
Test
REF MTB DTS 8- Indice B - February 21 2006
Page 5-21