MorphoAccess® SIGMA Extreme Series - Installation Guide  

Identity & Security

 

Section 1 :Introduction

 

 

12 

This document and the information therein are the property of 

Safran Identity & Security

They must not be copied or communicated to a third party without the prior written authorization of Safran

  

2017_2000024418 - V1 

April 2017

 

 

Safety Instructions 

means Direct Current (DC) 

The installation of this product should be made by a qualified service Person and should 
comply with all local regulations. 

It is strongly recommended to use a class II power supply at 12V-24V and 1A. min (at 
12V) in conformity with Safety Electrical Low Voltage (SELV). The  power supply cable 
length should not exceed 10 meters. 

This system must be installed in accordance with the National Electrical Code (NFPA 
70), and the local authority having jurisdiction. 

This product is intended to be installed with a power supply complying with IEC60950-
1, in accordance with the NEC Class 2 requirements; or supplied by a listed IEC60950-1 
external Power Unit marked Class 2, Limited Power source, or LPS and rated 12VDC, 1A 
minimum or 24VDC, 0.5A minimum. 

In case of building-to-building connection it is recommended to connect 0V to ground. 
Ground cable must be connected with the terminal block Power Ground. 

Note  that  all  connections  of  the  MorphoAccess®  SIGMA  Extreme  Series  terminal 
described hereafter are of SELV (Safety Electrical Low Voltage) type. 

 

 

Summary of Contents for MorphoAccess SIGMA Extreme Series

Page 1: ...MorphoAccess SIGMA Extreme Series Installation Guide COPYRIGHT 2017 Safran Identity Security Osny France 2017_2000024418 V1 April 2017 Identity Security...

Page 2: ...reserved Reproduction in whole or in part in any form or medium without the express written permission of Safran Identity Security is prohibited The trademarks identified herein are the trademarks of...

Page 3: ...tion therein are the property of Safran Identity Security They must not be copied or communicated to a third party without the prior written authorization of Safran 3 Revision History The table below...

Page 4: ...an Union CE regulatory notices 14 USA FCC regulatory notices 15 Canada IC regulatory notices 16 Others recommendations 17 Recommendations for terminal implementation 18 Section 2 General Description 2...

Page 5: ...1 The controller supports LED1 and LED2 signals 42 Serial port wiring 43 DataClock Input 43 DataClock Output 43 RS485 44 RS422 44 GPIO wiring 45 Single Door Access Control SDAC implementation 45 Ether...

Page 6: ...chronization 61 Cleaning precautions 62 Legacy mode 62 Micro SD card 64 Lighting conditions for face detection 64 Main principles 66 Most useful areas for biometric data 67 Position of finger 68 Finge...

Page 7: ...document and the information therein are the property of Safran Identity Security They must not be copied or communicated to a third party without the prior written authorization of Safran 7 Europe a...

Page 8: ...29 Figure 7 Face camera viewing angle 31 Figure 8 Drilling template 32 Figure 9 Wall plate fixing 33 Figure 10 Cable preparation connector cut 34 Figure 11 Cable preparation cable position for water t...

Page 9: ...commendations Identity Security 2017_2000024418 V1 April 2017 This document and the information therein are the property of Safran Identity Security They must not be copied or communicated to a third...

Page 10: ...es Safran Identity Security image processing and feature matching algorithms This technology is based on lessons learned during 25 years of experience in the field of biometric identification and the...

Page 11: ...SIGMA Extreme Series which is made up of following list of products MA SIGMA Extreme Series Marketing Name Biometrics Fake Finger Detection Contactless smartcard reader Water Resistant Regulatory Mode...

Page 12: ...ety Electrical Low Voltage SELV The power supply cable length should not exceed 10 meters This system must be installed in accordance with the National Electrical Code NFPA 70 and the local authority...

Page 13: ...an Identity Security recommends using a gauge AWG20 for 12V power supply when POE supply is not used The voltage specified is the one measured on the product block connector 12V 24V 15 10 For informat...

Page 14: ...e with these directives is assessed using applicable European Harmonised Standards MorphoAccess SIGMA Extreme Series terminals are intended to be used for professional application only buildings airpo...

Page 15: ...ed and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a re...

Page 16: ...l radio interference to other users the antenna type and its gain should be so chosen that the equivalent isotropically radiated power e i r p is not more than that necessary for successful communicat...

Page 17: ...hissing or popping sound or a strong odor or smoke coming from the product It is normal for these conditions to appear when an internal electronic component fails in a safe and controlled manner Howe...

Page 18: ...tallation Plan the installation Choose the type of hardware required decide if a network is required and decide on the location and number of required terminals Unpack all items Unpack all items and c...

Page 19: ...eme Series terminal itself Its role is to perform one to many biometric identification or one to one biometric verification i e to identify the individual who is presenting his finger on the terminal...

Page 20: ...pulling and anti tamper switches for more explanations The Controller is part of the global Access Control System of the secured area which can provide useful features such as manage authorized user l...

Page 21: ...endations Identity Security 2017_2000024418 V1 April 2017 This document and the information therein are the property of Safran Identity Security They must not be copied or communicated to a third part...

Page 22: ...rty without the prior written authorization of Safran 2017_2000024418 V1 April 2017 Box opening At the box opening components shall be extracted from the protection casing as depicted in the pictures...

Page 23: ...000024418 V1 April 2017 This document and the information therein are the property of Safran Identity Security They must not be copied or communicated to a third party without the prior written author...

Page 24: ...ty Security They must not be copied or communicated to a third party without the prior written authorization of Safran 2017_2000024418 V1 April 2017 Terminal s front view description Figure 4 MorphoAc...

Page 25: ...y They must not be copied or communicated to a third party without the prior written authorization of Safran 25 Terminal s rear view description Figure 5 MorphoAccess SIGMA Extreme Series terminal rea...

Page 26: ...WVGA color capacitive Touchscreen VGA camera for face image capture and videophone Powerful Loudspeaker Microphone Biometrics MorphoSmart Optic Biometric Module inside 23 23mm 500dpi 256 gray levels o...

Page 27: ...supply 1A min 12V Or by Power Over Ethernet through RJ 45 connector Note for UL 294 Compliance power supply shall be UL 294 and UL 294B with power limited output Security of the terminal Anti tamper p...

Page 28: ...nstallation Procedure 28 This document and the information therein are the property of Safran Identity Security They must not be copied or communicated to a third party without the prior written autho...

Page 29: ...to the installation Make sure that you have all the components described in Components of the initial package section at your disposal Remove the wall plate Keep this element at hand Figure 6 Removin...

Page 30: ...screws above One 1 Drill with a drill bit diameter adapted to raw plugs above One 1 hole saw depending on installation case A 1 Torx T20 screwdriver Deadbolt door strike Snubber diode required to prot...

Page 31: ...mera viewing angle The recommended height for fixing of the terminal is 1 30m camera height For an optimal use the terminal must be installed in an area where the lighting conditions are controlled Av...

Page 32: ...ate has a good flatness Figure 8 Drilling template If not present drill in the wall a hole with a diameter adapted to the width of the terminal and the cable to be hosted in see Figure 8 Drilling temp...

Page 33: ...afran Identity Security They must not be copied or communicated to a third party without the prior written authorization of Safran 33 Fixing Be sure that a sufficient space is reserved in the wall for...

Page 34: ...possible to use Molex PCB header reference 5016452620 Figure 10 Cable preparation connector cut Cable for wiring shall be AWG 20 to 24 length shall be adapted to the size of the hole in the wall to t...

Page 35: ...ndations Identity Security 2017_2000024418 V1 April 2017 This document and the information therein are the property of Safran Identity Security They must not be copied or communicated to a third party...

Page 36: ...Safran 2017_2000024418 V1 April 2017 Wiring overview Before proceeding make sure that the person in charge of installation and connections is properly connected to earth in order to prevent Electrost...

Page 37: ...upply External power supply Must comply with IEC 60950 1 standard 12V to 24V Dc regulated and filtered 1 Amp min at 12V Could be provided by a 12 Volts Wiegand power supply which complies with the Sec...

Page 38: ...ite Relay NC Contact relay normally closed Nominal characteristics of relay Load characteristics 1 A max 30 VDC according to the safety extra low voltage requirements independently of the power supply...

Page 39: ...Switch 1 Tamper switch contact 24 Pink Switch 2 Strip on tamper switch Operating principle for the switch Product installed on the wall plate switch enabled contact closed Product opened rear connecto...

Page 40: ...put Figure 17 Wiegand input wiring 6 Green Red WIEGAND_IN0 In Wiegand IN D0 Output type required Open drain or 5V 5 3 White Red WIEGAND_IN1 In Wiegand IN D1 Output type required Open drain or 5V 5 18...

Page 41: ...N 2 option panel feedback Output type required Open drain or 5V 5 8 Black Red WIEGAND_GND Ground for Wiegand The use of LED1 and LED2 wires is described in the paragraphs below The controller supports...

Page 42: ...nnected it must be constantly maintained in the high state The controller supports LED1 and LED2 signals When the controller supports one relay contact for each of the possible answers then The access...

Page 43: ...In Data Output type required Open drain only 3 White Red WIEGAND_IN1 In Clock Output type required Open drain only 18 Yellow GPO0 WIEGAND_LEDIN Out Card present signal if configured only one selectabl...

Page 44: ...Tx inverting signal 7 Black Red RS485_GND Ground RS485 implementation is limited to half duplex communication So only Tx Tx and ground reference signals are necessary Depending on the RS485 network a...

Page 45: ...Orange Black GPI_2 In Digital Input 1 8V to 5V 14 Yellow Black GPO_2 Out Digital Output 5V 5mA max 15 Orange Red GPI_1 In Digital Input 1 8V to 5V 16 Yellow Red GPO_1 Out Digital Output 5V 5mA max 17...

Page 46: ...y The POE doesn t provide enough power for both the terminal and the Wi Fi USB dongle Ethernet cable shall be shielded Default Ethernet configuration By default MorphoAccess SIGMA Extreme Series termi...

Page 47: ...ritten authorization of Safran 47 External USB connection Figure 26 External USB connection The external Micro USB can be used for administration only to connect a mass storage USB key with a standard...

Page 48: ...Safran Identity Security cable provided in the kit Product integrating Wi Fi dongle shall not be exposed to temperature exceeding 35 C and shall not be exposed to direct sun Wi Fi feature requires the...

Page 49: ...Micro SD card shall be used for the following features Database extension license is necessary Logs extension license is necessary Picture logs photo taking or face detection Dynamic messages Micro S...

Page 50: ...tion 5 User Interface 50 This document and the information therein are the property of Safran Identity Security They must not be copied or communicated to a third party without the prior written autho...

Page 51: ...ed in the internal database before they can request the access on the terminal This biometric data is acquired either directly on the terminal using the embedded or on an enrolment system using the sa...

Page 52: ...ation is located in a distant system This is not a standalone mode like Identification and Authentication modes It means that the terminal becomes a slave of the host system application The access con...

Page 53: ...cess shall be same as authentication Polling Process using buffer The user s input ID will be queued in the terminal s queue which is polled by external application External application waits for the...

Page 54: ...legacy system When the terminal is booted for the first time user can select any of the following modes MorphoAccess 500 or J Series legacy mode MorphoAccess SIGMA Extreme Series terminal can be opera...

Page 55: ...in the native mode The terminal can be configured using an internet browser connected to the embedded Webserver application NOTA When terminal mode is switched from MA5G to Morpho legacy mode the enti...

Page 56: ...ot big enough e g when the terminal is pulled out of the wall When the switches are deactivated the MorphoAccess SIGMA Extreme Series terminal acts as required by the related configuration key see Mor...

Page 57: ...ity Security 2017_2000024418 V1 April 2017 This document and the information therein are the property of Safran Identity Security They must not be copied or communicated to a third party without the p...

Page 58: ...following items can be ordered directly to Safran Identity Security or to an official distributor so as to enjoy all the features of your MorphoAccess SIGMA Extreme Series terminal Power supply units...

Page 59: ...9 Compatible PC applications MorphoAccess SIGMA Extreme Series terminals are fully compatible with MorphoManager version 11 or higher Morpho Integrator s Kit MIK software development kit version 6 or...

Page 60: ...ion 7 Recommendations 60 This document and the information therein are the property of Safran Identity Security They must not be copied or communicated to a third party without the prior written autho...

Page 61: ...ed Areas containing combustibles It is strongly recommended that you do not install your terminal in the vicinity of gas stations petroleum processing facilities or any other facility containing flamm...

Page 62: ...re or power down is longer the date time of the terminal will be lost Cleaning precautions The use of a dry cloth is recommended to clean the terminal especially the biometric sensor Acid liquids alco...

Page 63: ...nnector Only RJ45 connector Serial communications OMA500 family MA SIGMA Extreme family Wiegand Data In 2 Data Out 2 LED In 1 LED Out 2 Data In 2 Data Out 2 LED OUT port LED IN by GPO Dataclock Yes Ye...

Page 64: ...d the following recommendations shall be applied Micro SD card class shall be 10 lower class may reduce performances Micro SD card size shall be from 8GB to 32GB Micro SD card shall never be used on a...

Page 65: ...ons Identity Security 2017_2000024418 V1 April 2017 This document and the information therein are the property of Safran Identity Security They must not be copied or communicated to a third party with...

Page 66: ...V1 April 2017 Main principles Acquisition needs to be done with extreme care in order to get the best image quality increase recognition performance reduce recognition time Then it is highly recommend...

Page 67: ...017 This document and the information therein are the property of Safran Identity Security They must not be copied or communicated to a third party without the prior written authorization of Safran 67...

Page 68: ...ion therein are the property of Safran Identity Security They must not be copied or communicated to a third party without the prior written authorization of Safran 2017_2000024418 V1 April 2017 Positi...

Page 69: ...ocument and the information therein are the property of Safran Identity Security They must not be copied or communicated to a third party without the prior written authorization of Safran 69 Finger in...

Page 70: ...24418 V1 April 2017 Troubleshooting When finger biometric data acquisition is difficult please follow the recommendations listed below The finger is cold o Solution warm up the finger The finger is we...

Page 71: ...phy Identity Security 2017_2000024418 V1 April 2017 This document and the information therein are the property of Safran Identity Security They must not be copied or communicated to a third party with...

Page 72: ...d or communicated to a third party without the prior written authorization of Safran 2017_2000024418 V1 April 2017 How to get the latest versions of documents The last version of the documents can be...

Page 73: ...and the basics of configuration and use This document is in English MorphoAccess SIGMA Extreme Series Administrator Guide Ref 2017_2000025464 This document describes the different functions available...

Page 74: ...Security They must not be copied or communicated to a third party without the prior written authorization of Safran 2017_2000024418 V1 April 2017 Release note For each firmware version a release note...

Page 75: ...ort Identity Security 2017_2000024418 V1 April 2017 This document and the information therein are the property of Safran Identity Security They must not be copied or communicated to a third party with...

Page 76: ...oubleshooting The terminal IP address is unknown or it is not possible to connect to the terminal Use terminal interface to configure a valid set of network parameters in your terminal The sensor is s...

Page 77: ...Africa Mail sec san bio support morpho com Tel 27 11 286 5855 India Mail support morphoindia safrangroup com Tel 0120 4699900 Europe and rest of the world Mail hotline biometrics safrangroup com Tel 3...

Page 78: ...tity Security Annex 3 Support 78 This document and the information therein are the property of Safran Identity Security They must not be copied or communicated to a third party without the prior writt...