COMMAND RANGING & TELEMETRY UNIT CORTEX
Is.Rev.
Date:
© Safran Data Systems
This document is the property of
Safran Data Systems
.
It cannot be duplicated or distributed without expressed written consent.
Page 35
1.6.10.
Optional RF Stage
Available only with the option Embedded Frequency Converter
1.6.10.1.
Down Convertor Specifications
RF input stages
3
RF input ports
1 per input stage (Nominal)
Input frequency
930 to 2400 MHz
Input impedance
50
Ω
Output frequency
70MHz +/- 20MHz
Output impedance
50
Ω
Return loss
> 15 dB (both Input & Output)
Input level
From -20dBm to -105dBm
Maximum total power level
< -20dBm (or No=-110dBm/Hz for 1GHz noise limited bandwidth)
Independent spurious level
< -90 dBm signal dependent at max gain in output bandwith
Gain
2 modes available:
- Automatic control mode
- Manual mode:
from +10dB to +25dB with Model S105576
from +15dB to +30dB with Model S108984
Noise Figure
Typical 12dB @ maximum gain with Model S105576
Typical 10dB @ maximum gain with Model S108984
1.6.10.2.
Up Convertor Specifications
RF output stages
2
RF output ports
1 per input stage (Nominal)
Output frequency
950 to 2400 MHz
Output impedance
50
Ω
Input frequency
70MHz +/- 20MHz
Input impedance
50
Ω
Return loss
> 15 dB (both Input & Output)
Mute (ON/OFF)
> 60dB
Output level
from +5dBm to -80dBm
Dependent spurious level
< -60 dBc in output bandwidth @Pout > -20dBm
Noise density
< -112 dBm/Hz