32
problem
possible cause
remedy
When attempting a
measurement, the
display "- - -" appears
Minimum/maximum
measuring range exceeded
Take the specified range into
account
Target object’s reflectivity is
insufficient
See factors affecting the range
measurements (page 19)
Display shows “Lo” or
no function
Battery exhausted
Replace battery (see page 13)
Bluetooth data
transmission is not
working (fast flashing
Bluetooth symbol)
The counter device or the
Bluetooth option is turned
off
Turn on the counter device and
Bluetooth option
The counter device is not
paired with the TERRAPIN X
Set up a Bluetooth connection
with a new counter device (see
TECHNICAL DATA
optics
Observation
monocular
Magnification
8×
Field of view
103 mil / 5.8°