background image

 

 

5.5.4.

 

HI / LO Alert 

 

To set HI/LO temperature alert: 

1.

 

Press the up/down button to select the HI/LO Alert option in the Settings menú 

2.

 

Press the SET button to enter the HI/LO Alert submenú 

3.

 

Press the up/down button to select the desired option 

4.

 

Select HI or LO to adjust the temperature parameter 

5.

 

Select other options to turn the alert on or off 

6.

 

Press the back button to exit 

5.5.5.

 

Measurements 

 

To set measurements parameters: 

1.

 

Press the up/down button to select the Measurements option in the Settings menú 

2.

 

Press the SET button to enter the Measurements submenú 

3.

 

Press  the  up/down  button  to  select  the  Emissivity  or  Temperature  Comp 
(Temperature Compensation) 

4.

 

Press  the  SET  button  to  enter  the  parameters  adjustment  statetemperature 
parameter 

5.

 

Press the up/down button to increase or decrease the value 

6.

 

Press the SET button to save the current setting 

7.

 

Press the back button to exit 

NOTE: For emissivity values of common materials, please refer to the Common Emissivity 

5.5.6.

 

Display Brightness 

 

To set Display Brightness: 

1.

 

Press  the  up/down  button  to  select  the  Display  Brightness  option  in  the  Settings 
menú 

2.

 

Press the SET button to enter the Display Brightness submenú 

3.

 

Press the up/down button to select the desired brightness level from Low, Medium 
and High 

4.

 

Press the SET button to confirm 

5.

 

Press the back button to exit 

5.5.7.

 

Auto Power Off 

 

To set Auto power off: 

1.

 

Press the up/down button to select the Auto power off option in the Settings menú 

2.

 

Press the SET button to enter the Auto power off submenú 

3.

 

Press the up/down button to select the desired option from 5, 10, 30 minutes or Off 

4.

 

Press the SET button to confirm 

5.

 

Press the back button to exit 

 

Summary of Contents for SF-HANHELD-160T05E

Page 1: ...SF HANHELD 160T05 E Body Tmperature Scanner System User Manual...

Page 2: ...r outlets When the measured objetct comes from a place with a large temperatura difference from the measurement environment keep it in the measurement environment for 10 to 30 minutes before measuring...

Page 3: ...s 15 Right button 7 Trigger 16 Backb button 8 LCD display 17 SET button 9 Power button 18 Tripd mounting hole 3 Display Display size 2 8 Display resolution 320 vertical x 240 horizontal pixels Item De...

Page 4: ...ion 3 Press the SET button to enter the Measurement men 4 Press the up down button to select Center Spot Center point measurement or Hi Lo Spot Maximum and m nimum temperatura measurement 5 Press the...

Page 5: ...s the SET button to turn off the point Press the back button to exit 5 4 Image Mode 1 Press the SET button to open the main men 2 Press the left right button to select the option 3 Press the SET butto...

Page 6: ...utton to selec the Date and Time option in the settings men 2 Press the SET button to enter the Date and Time submen 3 Press the left right button to select the parameter to be adjusted 4 Press the SE...

Page 7: ...re parameter 5 Press the up down button to increase or decrease the value 6 Press the SET button to save the current setting 7 Press the back button to exit NOTE For emissivity values of common materi...

Page 8: ...ss the up down button to select YES or NO 4 Press the SET button to confirm 5 Press the back button to exit NOTE Do not remove or insert the SD carda in saving pictures It is recommended to save no mo...

Page 9: ...rmat SD card option in the System Settings submenu 2 Press the SET button to enter 3 Press the up down button to select YES 4 Press the SET button to confirm 5 Press the back button to exit NOTE Durin...

Page 10: ...athena visiotech s3 eu west 1 amazonaws com nx9xDHEBlrFzs_pSrxzY 2 Connect the USB cable to the PC 3 Set the USB mode to USB disk to browse pictures and analyze data through the PC software set the U...

Page 11: ...added Certifications CE EN 61326 1 2013 EN 61326 2 2 2013 EN 61326 2 3 RoHS Visual Light camera Yes Visual light resolution 640 x 480 pixels Image blending ratio 0 pure visual light image 25 50 75 and...

Page 12: ...Maintenance Use a wet cloth or weak soap solution to clean the outer Shell of the device Do not use abrasives isopropyl alcohol or solvents to clean the outer Shell lens or window 9 Common Emissivity...

Reviews: