![SAFI DN15 Manual Download Page 7](http://html1.mh-extra.com/html/safi/dn15/dn15_manual_3389936007.webp)
TYP
E 1
003/
2003
/2
016
/2
01
7
2027/
20
35
/2038
/2
062
TDS-BALL-1003-00-EN
01/02/2018
Les descriptions et caractéristiques figurant sur ce document sont données uniquement à titre d’information et non d’engagement
contractuel. SAFI se réserve le droit d’effectuer sans préavis, toute modification.
SAFI has a policy of continuously developing its product range and the above data is subject to change without prior notification.
www.safi-valves.com
7
Die Beschreibungen und Daten, die sich auf diesem Dokument befinden, sind rein informativ und unverbindlich. SAFI behält sich vor,
ohne Vorankündigung Änderungen vorzunehmen, die als technisch notwendig erachtet werden.
Las descripciones y características que figuran en este documento son indicativas. En ningún caso son contractuales. SAFI se reserva el
derecho sin previo aviso de efectuar cualquier modificación.
PP
GF
PVD
F
Pressure/Temperature Summary
PRESSURE LOSS
CHEMICAL RESISTANCE
DN
Kv (m
3
/h)
15
12,6
20
24,2
25
44,6
32
66,0
40
109,3
50
189,9
Kv defined according to NF EN 1267
Opening Angle (°)
Opening (%)
Kv
(
%
)
The mechanical characteristics of the FPM and FFPM seals subjected to an ambient temperature below –5°C require the implementation of
proper insulation on the valves equipped with such seals. Contact us for more information.
Type of Seals
Working pressure
Working Temperature
PPGF
PVDF
EPDM
10 bars at 20°C
- 10°C to +100°C
- 20°C to +120°C
FPM
10 bars at 20°C
- 5°C to +100°C
- 5°C to +120°C
FEP/FFPM
6 bars at 20°C
- 5°C to +100°C
- 5°C to +120°C
The chemical resistance of the valve is subject to the type of fluid, the temperature, the pressure, as well as the materials and
seals of the valve.
Please contact us to have a personalized analysis of the resistance of one of our products to a given fluid
You can also consult, for information only, the table given in ISO 10358. However, this table cannot be considered as a
recommendation by SAFI who could not be held liable for the use of this document.
Our valves are guaranteed for an average fluid velocity in the pipeline of ≤ 2 m/s. Please contact us with the working conditions for any higher
speed.