V1.0 2023 Copyright Safewaze
220-00089
SRL-P Instruction Manual
OSHA
1910.140, 1910.66
This manual is intended to meet manufacturer’s instructions as
required and should be used as part
of an employee training program as required by OSHA.
Page 1: ...t Safewaze 220 00089 SRL P Instruction Manual OSHA 1910 140 1910 66 This manual is intended to meet manufacturer s instructions as required and should be used as part of an employee training program a...
Page 2: ...ING FALLS 9 11 0 FALL PROTECTION AND RESCUE PLAN 10 12 0 NORMAL OPERATIONS 10 13 0 COMPATIBILITY OF COMPONENTS 10 14 0 COMPATIBILITY OF CONNECTORS 10 15 0 USE 11 16 0 MAINTENANCE SERVICE AND STORAGE 1...
Page 3: ...e contact with sharp or abrasive surfaces DO NOT use combinations of components or subsystems or both that may affect or interfere with the safe function of each other DO NOT alter equipment DO NOT mi...
Page 4: ...t L i f e l i n e M a t e r i a l L i f e l i n e D i m e n s i o n s i n H o u s i n g M a t e r i a l W e i g h t l b s S t e e l S n a p H o o k L I S t e e l S w i v e l S n a p H o o k A L U S n...
Page 5: ...1926 502 Anchorages used for attachment of personal fall arrest systems shall be independent of any anchorage being used to support or suspend platforms and capable of supporting at least 5 000 lbs 22...
Page 6: ...the Dorsal D ring up to a maximum distance of 5 1 5 m Latitude Pro Tie Back SRL Ps are designed for use below the Dorsal D ring up to a maximum of 2 61 m HOUSING Nylon WEBBING 20 mm Ultrahigh Molecula...
Page 7: ...eet 0 1 2 3 4 5 6 7 8 9 10 11 12 12 7 6 2 3 m 7 6 2 3 m 7 6 2 3 m 8 3 2 5 m 8 6 2 7 m 9 2 7 m 9 3 2 8 m 9 6 2 9 m 9 9 3 0 m 11 3 3 4 m 12 3 7 m 12 9 3 9 m 13 3 4 0 m 11 7 6 2 3 m 7 6 2 3 m 8 3 2 5 m 8...
Page 8: ...rcumference of 36 The graphics illustrated in Figure 3 indicate the Free Fall distance s associated with above and below D ring use Free Fall distances are based on the anchorage distance above or bel...
Page 9: ...nal fall clearance requirements if a Swing Fall Hazard is present when using a Latitude Latitude Pro SRL P in an overhead application The Y Axis represents the height the SRL is anchored above the use...
Page 10: ...nt is designed for use with Safewaze components and subsystems only A Qualified Person should make the determination of Safewaze equipment compatibility with equipment not manufactured by Safewaze Rep...
Page 11: ...the worker and tagged Unusable If any component of the users PFAS indicates damage it must be IMMEDIATELY removed from service and destroyed or contact Safewaze for repair services 1 2 3 4 FIGURE 8 SW...
Page 12: ...cket onto harness Use the following instructions and Figure 10 to install the bracket Connect to Harness 1 Unfasten the two small brackets on the green retractable spacer off of the carabiner 2 Slide...
Page 13: ...Type of Use Application Examples Conditions of Use Inspection Frequency Competent Person Infrequent to Light Rescue and Confined Space Factory Maintenance Good Storage Conditions Indoor or Infrequent...
Page 14: ...ALL INSTRUCTIONS AND WARNINGS INCLUDED WITH THIS EQUIPMENT DO NOT REMOVE LABEL 470 00154 WARNING This is a single user fall arrester device Device must be inspected prior to each use Connection of th...
Page 15: ...Hook Body Rivets Corrosion Pitting Nicks CONNECTORS PASS FAIL NOTE Termination Stitch Splice or Swage Cuts Fraying Broken Stitching Excessive Wear Cable Separating Bird Caging Entire Length Retracts S...
Page 16: ...ION DIAGRAMS Latitude Pro 7 Tie Back SRL P Webbing Load Impact Indicator Labeling Labeling Labeling Swivel Top Carabiner Snaphook Additional Labeling Cover Hook Body Load Impact Indicator Gate Snaphoo...