SafeWaze LATITUDE TIE BACK Instruction Manual Download Page 8

Page 8

V1.0 2023 Copyright Safewaze

WARNING:

  Latitude / Latitude Pro Tie-Back SRL-Ps 

ARE NOT 

designed for, and should 

NEVER 

be used in an environment 

where a Leading Edge Hazard exists. If work involves a Leading Edge hazard, a Class 2 SRL must be used.   

Latitude Tie-Back Connection Example

Latitude Pro Tie-Back Connection Example

FIGURE 2 - TIE-BACK SRL OPERATION

LOAD IN

DICATO

R

LOA

D IN

DIC

ATO

R

A

FALL-ARREST

     

     

020

049

1

2

PUSH

SLID

E TO 

OPEN

TIE-BACK

LOAD IN

DICATO

R

LOA

D IN

DIC

ATO

R

A

FALL-ARREST

ANSI

 Z3

59.

14,

 AN

SI A1

0.32

 

OSH

A 1

910

.66

, O

SHA 

192

6.5

02

    

     

 02

005

0

Latitude 6’ Tie-Back SRL-P

5 ft.

4 ft.

3 ft.

2 ft.

1 ft.

0 ft.

-1 ft.

-3 ft.

-4 ft.

-5 ft.

-2 ft.

LOAD IN

DICATO

R

LOA

D IN

DIC

ATO

R

A

FALL-ARREST

TI

E-

BA

CK

X-

TR

EM

E

          

0200

49

1

2

PUSH

SLIDE TO OPEN

FREE 

FALL

FREE 

FALL

ANCHORAGE 

DISTANCE ABOVE 

OR BELOW D-RING 

ANCHORAGE 

DISTANCE ABOVE 

OR BELOW D-RING 

0 ft

 

0 ft

 

0 ft

 

0 ft

 

0 ft

 

0 ft

 

0 ft

 

0 ft

 

0 ft

 

2 ft

 

0 ft

 

1 ft

 

2 ft

 

4 ft

 

1 ft

 

3 ft

 

3 ft

 

5 ft

 

4 ft

 

5 ft

 

A: Tie-Back ANCHORAGE

B: Tie-Back ANCHORAGE

30-36” CIRCUMFERENCE

9-14” CIRCUMFERENCE

0 ft

 

FREE 

FALL

ANCHORAGE 

DISTANCE ABOVE 

OR BELOW D-RING 

0 ft

 

0 ft

 

0 ft

 

0 ft

 

0 ft

 

0 ft

 

0 ft

 

1 ft

 

2 ft

 

D: DIRECT ANCHORAGE

1.5 ft.

2.5 ft.

3.5 ft.

4 ft.

5 ft.

6 ft.

7 ft.

8 ft.

9 ft.

10 ft.

LOAD IN

DICATO

R

LOA

D IN

DIC

ATO

R

A

FALL-ARREST

     

     

02

00

49

1

PUSH

2

SLIDE TO OPEN

 

 
 
 
 
 
 
 
 
 

Latitude Tie-Back SRL-Ps may be anchored up to 5’ (1.5 m) below the user’s Dorsal D-ring when fully tied back and can accommodate a circumference of 36”. 

The graphics illustrated in Figure 3 indicate the Free Fall distance(s) associated with above and below D-ring use. Free Fall distances are based on the anchorage 

distance above or below the Dorsal D-ring and the circumference of the anchorage to which the SRL is attached.

FIGURE 3 - LATITUDE TIE-BACK SRL- P (FREE FALL DISTANCE)

The Latitude/Latitude Pro Tie-Back SRL-Ps are designed and tested for use below the Dorsal D-ring when fully or partially tied back. The user must account for 

additional clearance requirements when the anchor point is located below the Dorsal D-ring. Be sure to factor in the circumference of the anchor you are tying 

back to when calculating your fall clearance requirements. 

 If your tie-back unit has a standard hook and 

not a tie-back snap hook, then you must utilize 

the D-ring provided for tie-back and cannot 

tie-back to the lifeline.

5 ft.

4 ft.

3 ft.

2 ft.

1 ft.

0 ft.

-1 ft.

-3 ft.

-2 ft.

LOAD IN

DICATO

R

LOA

D IN

DIC

ATO

R

A

FALL-ARREST

      

    0

200

49

1

2

PUSH

SLIDE TO OPEN

TI

E-

B

AC

K

X-T

RE

ME

FREE 

FALL

ANCHORAGE 

DISTANCE ABOVE 

OR BELOW D-RING 

0 ft

 

0 ft

 

0 ft

 

0 ft

 

1 ft

 

0 ft

 

3 ft

 

2 ft

 

4 ft

 

5 ft

 

C: Tie-Back ANCHORAGE

15-29” CIRCUMFERENCE

5 ft.

4 ft.

3 ft.

2 ft.

1 ft.

0 ft.

-1 ft.

-3 ft.

-2 ft.

-4 ft.

LOAD IN

DICATO

R

LOA

D IN

DIC

ATO

R

A

FALL-ARREST

1

2

PUSH

SLIDE TO OPEN

         

 020

049

TI

E-

BA

CK

X-T

RE

ME

Figure 2 illustrates the typical Latitude/Latitude Pro Tie-Back SRL-P anchorages and connections. Select an anchorage location with minimal free fall and swing 

fall hazards. Select a rigid anchorage point capable of sustaining static loads as defined in Section 6. See diagrams below for examples.

Summary of Contents for LATITUDE TIE BACK

Page 1: ...t Safewaze 220 00089 SRL P Instruction Manual OSHA 1910 140 1910 66 This manual is intended to meet manufacturer s instructions as required and should be used as part of an employee training program a...

Page 2: ...ING FALLS 9 11 0 FALL PROTECTION AND RESCUE PLAN 10 12 0 NORMAL OPERATIONS 10 13 0 COMPATIBILITY OF COMPONENTS 10 14 0 COMPATIBILITY OF CONNECTORS 10 15 0 USE 11 16 0 MAINTENANCE SERVICE AND STORAGE 1...

Page 3: ...e contact with sharp or abrasive surfaces DO NOT use combinations of components or subsystems or both that may affect or interfere with the safe function of each other DO NOT alter equipment DO NOT mi...

Page 4: ...t L i f e l i n e M a t e r i a l L i f e l i n e D i m e n s i o n s i n H o u s i n g M a t e r i a l W e i g h t l b s S t e e l S n a p H o o k L I S t e e l S w i v e l S n a p H o o k A L U S n...

Page 5: ...1926 502 Anchorages used for attachment of personal fall arrest systems shall be independent of any anchorage being used to support or suspend platforms and capable of supporting at least 5 000 lbs 22...

Page 6: ...the Dorsal D ring up to a maximum distance of 5 1 5 m Latitude Pro Tie Back SRL Ps are designed for use below the Dorsal D ring up to a maximum of 2 61 m HOUSING Nylon WEBBING 20 mm Ultrahigh Molecula...

Page 7: ...eet 0 1 2 3 4 5 6 7 8 9 10 11 12 12 7 6 2 3 m 7 6 2 3 m 7 6 2 3 m 8 3 2 5 m 8 6 2 7 m 9 2 7 m 9 3 2 8 m 9 6 2 9 m 9 9 3 0 m 11 3 3 4 m 12 3 7 m 12 9 3 9 m 13 3 4 0 m 11 7 6 2 3 m 7 6 2 3 m 8 3 2 5 m 8...

Page 8: ...rcumference of 36 The graphics illustrated in Figure 3 indicate the Free Fall distance s associated with above and below D ring use Free Fall distances are based on the anchorage distance above or bel...

Page 9: ...nal fall clearance requirements if a Swing Fall Hazard is present when using a Latitude Latitude Pro SRL P in an overhead application The Y Axis represents the height the SRL is anchored above the use...

Page 10: ...nt is designed for use with Safewaze components and subsystems only A Qualified Person should make the determination of Safewaze equipment compatibility with equipment not manufactured by Safewaze Rep...

Page 11: ...the worker and tagged Unusable If any component of the users PFAS indicates damage it must be IMMEDIATELY removed from service and destroyed or contact Safewaze for repair services 1 2 3 4 FIGURE 8 SW...

Page 12: ...cket onto harness Use the following instructions and Figure 10 to install the bracket Connect to Harness 1 Unfasten the two small brackets on the green retractable spacer off of the carabiner 2 Slide...

Page 13: ...Type of Use Application Examples Conditions of Use Inspection Frequency Competent Person Infrequent to Light Rescue and Confined Space Factory Maintenance Good Storage Conditions Indoor or Infrequent...

Page 14: ...ALL INSTRUCTIONS AND WARNINGS INCLUDED WITH THIS EQUIPMENT DO NOT REMOVE LABEL 470 00154 WARNING This is a single user fall arrester device Device must be inspected prior to each use Connection of th...

Page 15: ...Hook Body Rivets Corrosion Pitting Nicks CONNECTORS PASS FAIL NOTE Termination Stitch Splice or Swage Cuts Fraying Broken Stitching Excessive Wear Cable Separating Bird Caging Entire Length Retracts S...

Page 16: ...ION DIAGRAMS Latitude Pro 7 Tie Back SRL P Webbing Load Impact Indicator Labeling Labeling Labeling Swivel Top Carabiner Snaphook Additional Labeling Cover Hook Body Load Impact Indicator Gate Snaphoo...

Reviews: