15
WARNING
Ensure the correct sensor direction:
sensors
❺
should look towards the
cooker.
Make sure that there is no obstruction
in the sensor's
❺
field of view between
the sensor unit
Ⓐ
and the stove.
4.4 Mount the sensor unit
Ⓐ
1. Remove grease and dirt from the
surface before attaching the sensor
unit
Ⓐ
with the adhesive tape
❻
.
2. Remove the protection strips from
the adhesive tape
❻
.
3. Mount the sensor unit
Ⓐ
according
to the table below and adjacent
figures.
Installation
Height (H)
Wall mount, cooker width
up to 60 cm
50 cm *
± 5 cm
Wall mount, cooker width
from 60 cm to 90 cm
60 cm
± 5 cm
* For Quick Installation
use the default
position for electric cookers: no
configuration is needed and you can
finish the installation by checking the
working order according to the chapter
4.6.
The sensor unit
Ⓐ
should be mounted
on the centerline of the cooker.
Make sure that the mounting location
is free of direct sunlight and other
sources of powerful light and heat.
H
+8°
-8°
Sensors
❺
field of view
max.
60 cm