Sensors’
field of view
Sensors’
field of view
Cooker hood
1. Wall / splashback
Use the wall mount bracket (installed by
default). The Sensor Unit should be in-
stalled levelled, so that the sensors are
pointing downwards towards the stove.
2. Extraction hood underside
Use the cooker hood bracket (separate in
the delivery box). The Sensor Unit should
be installed levelled at on the bottom of
the cooker hood. The front edge of the
Sensor Unit should be mounted near the
front of the hood, vertically in-line with the
front edge of the front cooking rings with
OK-button facing the user.
For the most up to date mounting method
and stove support information, please re-
fer to the “Installation Wizard” -section in
the Safera App. For the factory shipped
software version, the allowed mounting
height specifications are:
Installation
Height
Wall mount, stove width up
to 60 cm
50 cm
± 5 cm
Wall mount, stove width
from 60 cm to 90 cm
60 cm
± 5 cm
Cooker hood mount,
electric hob
width up to
60 cm
45 - 85 cm
Cooker hood mount,
electric hob
width from 60
cm to 90 cm
55 - 85 cm
Cooker hood mount,
gas
hobs
75 - 85 cm
Without changing any settings (and there-
fore using the mobile app), the sensor can
be mounted in the following positions.
• Wall mount, electric stove width up to
60 cm -- mounting height: 50 cm ± 5
cm
• Cooker hood mount, electric stove
width up to 60 cm -- mounting height:
60 cm ± 5 cm
Mounting height is measured from the
stove surface to the top of the Sensor Unit
enclosure.
The maximum supported stove width is
90cm.