SAFEGREASE, SAFEOIL, MULTILUBE
ST-1440
14402BEN.doc
12.11.2004 Rev. 2B
5 (19)
The third line indicates
•
either the pressure levels at the pressure transmitter channels (
L1:005bar L2:005bar
)
•
or the pressure switch channel switch status (
PS1 close PS2 open
)
Note
In pressure transmitter channels, the pressure level reads
Error
, if the
measured reading is lower than 0 bar (< 4 mA), which indicates that the
sensor circuit is broken. For example the sensor cable may not be
connected.
The fourth line indicates
•
the function key texts
The function key functions change according to the channel phase. For example, if the channel
is in alarm mode, one of the function keys acts as an alarm reset key.
Display function keys
Key Description
Chnl
Channel
selection
Press key to go to next channel.
Channel can also be selected with
Í
and
Î
keys, which can used for toggling
between channels up and down.
Page
Settings
display
Press key to go to channel settings display.
Stop
Stops
pressurization
Use key to stop channel pressurization in which case the channel goes into
interval phase.
Ack.
Alarm
reset
Press key to reset an alarm. The alarm can be reset only after the problem
causing the alarm has been resolved.
Manu
Manual
operation
Press key to use manual operation mode on the selected channel.
Extr
Extra lubrication
Press key to start an extra lubrication cycle for the selected channel.