17
17
SL1 v.2.1.0 EN
Other codes
Code Data
Comments
Emergency signal in
speaker
*71*
- #
The speaker siren will sound at emergency call.
1 = On (Default)
0 = Off
Ring tone timeout
*72*
- - #
Number of ring signals before dialling the next number.
Additional input function *73*
- #
Selects input function:
0 = None (Default)
1 = Filter, blocks the alarm input when active.
2 = LMS(Lift Monitoring System), sends a lift monitoring
alarm at input activation.
3 = Clear/Maintenance
Additional input type
*74*
- #
0 = Normally-open contact, NO (Default)
1 = Normally-closed contact, NC
Hot Line
*75*
- #
Phone connects directly to a fixed receipient without
dialling a phone number
0 = Standard phone line (Default)
1 = Hotline
Compatability mode
*77*
- #
0=Automatic voice switching
The call is validated when there is a voice response. The
call is terminated by pressing ”#”.
1=Kone ECII (lift telephone)
When there is a voice response, some ascending tones
will be heard. The call is validated by pressing ”4”. The
call is terminated by pressing ”0”. The call is terminated
without receipt notification by pressing ”2”(the unit will
call the next number).
2=Manual voice switching
When there is a voice response, some ascending tones
will be heard. The call is validated by pressing ”4”. Unit is
still in automatic mode. To enter manual mode and talk
press ”*”. To listen press ”7”. Go back to automatic mode
press ”4”. The call is terminated by pressing ”#”.
It is possible to enter manual voice switching mode
although the unit is configured as automatic by pressing
”*”. No ascending tones will be heard.
Indicator mode
*78*
- #
0 = Standard
1 = Strictly EN81-28
Voice communication
time-out
*79*
- #
1 - 20 minutes. Standard = 8 min
Reset active alarm automa-
tically
*80*
#
0 = OFF,
1 = ON (Default)