8
MX3+ v.2.02 EN
Overview
Outputs
Activate with DTMF 8
(Output 1, Configuration code 1)
The output is activated at the following events:
- DTMF tone 8 is received.
The output is deactivated at the following events:
- 3 seconds after activation.
Activate with DTMF 9
(Output 2, Configuration code 1)
The output is activated at the following events:
- DTMF tone 9 is received.
The output is deactivated at the following events:
- 3 seconds after activation.
System failure
(Output 1 & 2, Configuration code 2)
The output is activated at the following events:
- Telephone line OK.
The output is deactivated at the following events:
- Telephone line missing.
Emergency bell
(Output 1 & 2, Configuration code 3)
The output is activated at the following events:
- Emergency alarm button input active.
- The call is not yet connected.
The output is deactivated at the following events:
- Emergency alarm button input deactivated.
- The call is connected.
Silence disconnect
The function will automatically disconnect a call if no sound is
received from the alarm operator within a set time. Only works for
voice calls, not for P100/CPC/Q23.
The configuration is performed via SafeLine Pro or with the
configuration code *92*X#, where X specifies the time:
0 = The function is off.
1 = 30 seconds.
2 = 60 seconds (default).
3 = 90 seconds.
Volume control through software
The speaker volume is adjusted via the keyboard control. Key 2
raises and Key 8 lowers the volume in 6 steps. The volume can also
be adjusted using the command *76*X# where X is the desired
volume position between 1 and 6. Default value is 3.
The set volume mode are stored in the EEPROM so that the unit
remembers the set position.
External mic/voice station
When a call is activated by the emergency alarm button on
the external mic/voice station, the microphone on the external
mic/voice station will be used and the internal microphone
disconnected. The speaker sound will however be heard from both
speakers simultaneously.
Functions