16
MX3+ v.2.02 EN
Configuration
OTHER CODES
CODE
DATA
COMMENTS
Compatibility mode
*77*
- #
0 = Automatic voice switching
The call is validated when there is a voice
response.
The call is terminated by pressing ”#”.
1 = Kone ECII (lift telephone)
When there is a voice response, some
ascending tones will be heard.
The call is validated by pressing ”4”.
The call is terminated by pressing ”0”.
The call is terminated without reciept notification
by pressing ”2”(the unit will call the next number).
2 = Manual voice switching
When there is a voice response, some
ascending tones will be heard.
The call is validated by pressing ”4”. Unit is
still in automatic mode. ‘
To enter manual mode and talk press ”*”.
To listen press ”7”.
Go back to automatic mode press ”4”.
The call is terminated by pressing ”#”.
It is possible to enter manual voice switching
mode although the unit is programmed as
automatic by pressing ”*”. No ascending
tones will be heard.
For repeating the Alarm messages to
operator, press “1” in all in/out going calls.
3 = Swiss M (Alarm operator mode)
Only to be used in voice mode.
Disconnect by “0”.
Dials the next number if call timeout, blocking
tone, new dailing tone, and operator silence.
Indicator mode
*78*
- #
0 = Standard (default)
1 = Strictly EN81-28
2 = Strictly single EN81-28
Voice communication time-out
*79*
- - #
Value 1 - 20 minutes.
05 = default value
08 = default value for other protocols
Reset active alarm
automatically
*80*
- #
0 = Off
1 = On (default)
Auto answer
*81*
- - #
Number of signals before SafeLine answers
incoming call.
Can be set from 00-16 (default = 02).
00 = Never answering.
Unit number
*82*
- #
Unit number [0] is set by default, and means
that the unit will respond immediately.
Unit number [1-9] is used when the units
are sharing the same phone line. When the
unit number is assigned, the specified unit is
accessible for configuration.