background image

 

EU Declaration of Conformity GL6 V3.0

 

Your partner in lift safety

 

Antennvägen 10, 13548 Tyresö, Sweden 
+46 (0)8-447 79 32, www.safeline-group.com 

EU Declaration of Conformity 

 

 

Product: 

Mobile network emulator 

Type / model: 

Safeline GL6 

Article no: 

*GL6, *GL6-4G, *GL6-FC, *GL6-FC-4G 

Manufacturer: 

SafeLine Sweden AB 

Year: 

2020  

 
We herewith declare under our sole responsibility as manufacturer that the products referred to above 
complies with the following EC Directives: 

 

Directives 

Radio Equipment (RED): 

 

2014/53/EU 

 

RoHS 2: 

 

2011/65/EU 

 

Standards applied 

EN 12015:2014 

 

 

EMC: Emission, Electromagnetic compatibility 

EN 12016:2013 

 

 

EMC/Lifts: Immunity, Electromagnetic compatibility 

EN 62368–1:2014/AC:2015   

LVD: Information Technology Equipment 

EN 50581:2012 

 

RoHS: Technical doc. for assessment of restriction of RoHS. 

 
For RED 2014/53/EU, the conformity assessment procedure “Module A” used as described in Annex II. Accordingly, respective manufacturer 
has done the radio modules conformity assessment: 

 
Standards applied 

 

 

 

 

 

Article of Directive 2014/53/EU 

EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013 

 

3.1 (a): Health and safety of the user 

EN 62311:2008 

 

EN 301 489-1 v2.1.1 + EN 301 489-52v1.1.0 Draft   

 

3.1 (B): Electromagnetic Compatibility 

EN 301 511 v12.5.1

 

 

 

 

 

 

3.2: Effective use of spectrum allocated 

EN 301 908-1v11.1.1 /-2v11.1.1 /-13v11.1.1

 

 

Firmware used during assessment 

GL865-Dual V3:  

16.00.152 / 16.01.150 / 16.01.153

 

LE910-EU V2: 

20.00.402 

SafeLine GL6:  

1.00 

 
 
 
 
 
Tyresö, 2020-03-09 
 
 
 
Lars Gustafsson, 
Technical Manager, R&D , SafeLine Group  

Module 

Notified body 

Address 

NB nr 

Test nr 

1 GL865-Dual V3 2. 
LE910-EU V2 

Dekra Test &Cert 
Dekra Test &Cert 

Parque Tecnologico de Andalucia / SeveroOchoa 2, 
29590 Spain 

1909 
1909 

53051 RBN.001 
52382 RCB.001 

LE910C1-EU 

Dekra Testing and 
Certification 

Parque Tecnologico de Andalucia / Severo Ochoa 2, 
29590 Málaga, Spain 

1909 

57536RNB.001A1 
 

Summary of Contents for GL6

Page 1: ...www safeline group com 09 2020 2020SafeLineandalltheSafeLineproductsand accessoriesarecopyrightedbylaw GL6manual GSM gateways SafeLine GL6 v 2 1 1 EN Innovation brought to you from Tyres Sweden...

Page 2: ...P code IP20 Output 12 VDC maximum output 120 mA continuous 500 mA max 10 min Output indicator intercom 12 VDC max 100 mA Line voltage 48 VDC USB USB mini 2 0 Interface board SL6 GSM BOARD Supports 2G...

Page 3: ...diagram 6 Relay output 7 Intercom 8 Network services 9 Activating the SIM card 9 Indication LED 10 GSM field strength 11 Reset button 11 Configuration 12 Configuration with PC 12 SafeLine Pro 12 Oper...

Page 4: ...rer accepts no liability arising from printing errors mistakes or changes Declaration of conformity Download The declaration of conformity at our website www safeline group com Safety Precautions Only...

Page 5: ...e 7 RJ12 for telephone line 8 SMA antenna connector 9 Terminals C3 Lift Monitoring System LMS SMS Programmable input for LMS to send SMS messages to up to 3 different numbers 10 GND SafeLine GL6 is a...

Page 6: ...D C B A 1 2 1 2 3 5 6 7 1 2 4 1 2 12 V 0 V 230 VAC L 230 VAC N GND SafeLine GL6 v 2 1 1 EN Wiring diagram Battery Battery Input Relay 1 NO NC Input intercom only NO button Indicator intercom Telephone...

Page 7: ...Relay is active when battery test has failed 2 System failure Relay is active when GL6 has GSM network coverage Relay deactivates when GSM network is missing for more than 15 seconds or when mains po...

Page 8: ...Use of intercom When an intercom call is generated the GL6 rings up to 16 times waiting for a phone that is connected to the GL6 to answer LED3 indicates when a ringing call expires and when the call...

Page 9: ...ll be randomly generated by the SafeLine GSM unit and memorized This is a safety measure making sure the SIM card will only work with the selected SafeLine GSM unit To change the PIN again use the PUK...

Page 10: ...us red Battery test failure LED 3 indicates the phone line s status Slowly flashing green GSM network OK Flashing green Call connection in progress Flashing two times green Connected handset is not hu...

Page 11: ...3 times Start a battery test manually Press once Cancel battery test Press once Turn on when using battery power Reset Minimum signal strength for using GSM Interface GSM field strength If the reset...

Page 12: ...site after installation The configuration software SafeLine Pro can be downloaded from www safeline group com Configuration SafeLine Pro Use the latest version of SafeLine Pro The software can be dow...

Page 13: ...al input for monitoring Function Here you can set the input to different functions None Input 1 is not enabled default SMS Sends a text message when the input has reached the set value Type Sets the i...

Page 14: ...r 4 Text message Here you can enter information and specify the destination of the text message Battery failure SMS If the battery test fails a text message is sent SMS destination you can enter up to...

Page 15: ...o test alarms activated Battery failure simulates a battery test Mains power failure simulates a power failure LMS message simulates an operational alarm failure Functions LMS input lights green when...

Page 16: ...ile Equipment Identity The IMEI is used by the GSM and UMTS mobile phones The IMEI is used by yhe GSM network to identify and authorize mobile phones and can thus stop the stolen mobile phones and mak...

Page 17: ...minutes An SMS is sent to 3 destinations maximum and with a maximum of 128 characters External input 1 SMS There is an input for monitoring with the possibility to send SMS messages The input require...

Page 18: ...being connected Make sure the battery is properly charged Check voltage with the battery plug disconnected Call cannot be connected Error message from telephone operator To make a call area code must...

Page 19: ...conformity assessment procedure Module A used as described in Annex II Accordingly respective manufacturer has done the radio modules conformity assessment Standards applied Article of Directive 2014...

Page 20: ...SafeLine Denmark Vallensb kvej 20A 2 th 2605 Br ndby Denmark Tel 45 44 91 32 72 info dk safeline se SafeLine Headquarters Antennv gen 10 135 48 Tyres Sweden Tel 46 0 8 447 79 32 info safeline se Supp...

Reviews: