17
SafeLine GL6 v.2.1.1 EN
Use the latest version of
SafeLine Pro. The software
can be download from
www.safeline-group.com.
Battery check
• Automatic battery test
Battery capacity is tested every 7 days. The test takes 15 minutes
maximum. If the battery test fails LED2 is activated. An SMS is sent
to 3 destinations maximum and with a maximum of 128 characters.
• Manual battery test
Start battery test by pressing the reset button 3 times. To cancel the
test press reset button once.
• Battery discharge protection
When the GL6 runs on battery power, the battery saver function will
turn off the GL6 when the battery level reduces to 10.7 volts. When
the mains power is reconnected the GL6 powers up again.
Mains power control
The GL6 is constantly monitoring the mains power. If power failure
occurs an SMS regarding the power loss will be sent after 15
minutes. An SMS is sent to 3 destinations maximum and with a
maximum of 128 characters.
External input 1 (SMS)
There is an input for monitoring with the possibility to send SMS
messages. The input requires 12VDC and it is possible to choose
between N/O and N/C (N/O is default). An SMS is sent to 3 destina-
tions maximum and with a maximum of 128 characters.
GSM functions
GSM field strength indication is active for 10 seconds when it is
activated by the reset button. If the GSM network coverage is lost,
the GL6 will automatically restart the GSM module after 10 minutes.
The GL6 provides 48 VDC line power only when it has GSM
network.
Outgoing call
Maximum call time for outgoing calls is configurable in SafeLine Pro
from 1 to 99 minutes (0 = unlimited). When a call is interrupted, the
GL6 generates. 10 busy tones, before it returns to standby mode.
Configuration of GL6
Use the latest version of SafeLine Pro. Configuration can only be
done in “standby mode”. All configuration must be done using the
USB port. Serial port is only for factory use.
Operation