![Safeline GL6 Manual Download Page 15](http://html2.mh-extra.com/html/safeline/gl6/gl6_manual_3307803015.webp)
15
SafeLine GL6 v.2.1.1 EN
•
LMS input SMS
An text message is sent if the LMS input has reached the set
value.
SMS destination: you can enter up to 3 mobile phone
numbers.
Message: the limit for the message text is 128 characters
maximum.
5. Miscellaneous
Resets all input fields to their default value. Puts SafeLine Pro in
basic mode execution, empties phone fields etc.
6. Connection
Test
With a computer directly to GL6.
•
Alarm type
None: no test alarms activated.
Battery failure: simulates a battery test
Mains power failure: simulates a power failure.
LMS message: simulates an operational alarm failure.
•
Functions
LMS input: lights green when the input is active.
Intercom input: lights green when the intercom is activated.
GSM net: lights green when there is enough network
coverage.
Mains power: lights green when the input is active.
Relay output: toggles the output relay on and off.
Intercom output: toggles the intercom output on and off.
Line output active: lights green when the line output is active.
Read
Reads out the configuration of the GL6.
Write
Write changes to the GL6.