10

24VDC

2 A

TERM

ON

OFF

SD-CARD

USB 

+24V

CAN H

GND

CAN L

GND

IN 1

IN 2

IN 3

IN 4

IN 8

IN 5

IN 6

IN 7

SPK

GND
OUT
24V

GND

+24V

IPS

FD1600

Optional

FD1600 v.2.03 EN

Installation

Wiring Diagram 

FD1600 - IPS

Wiring diagram for car unit 

and/or floor units.

Grey

Orange

Black

Red

Green

Yellow

Blue

Brown

In car

Unit ID:

 CAR1

Main mode:

 

Ext. position unit (CAN)

Term: Off

NOTE!

 If only one display 

is used set Term to on.

Used for fixed messages

IPS: 

Install 

on car roof

Term: On

NOTE! 

If only one 

display is connected 

set Term to on.

Green

Grey

Brown

Yellow

White

Summary of Contents for FD1600

Page 1: ...ww safeline group com 09 2019 2019SafeLineandalltheSafeLineproductsand accessoriesarecopyrightedbylaw MadeinTyres Swedenwithqualityandcare FD1600 Manual Floor Displays Voice Announcers FD1600 v 2 03EN...

Page 2: ...cators component list 6 Inputs 7 Wiringdiagram FD1600 8 WiringDiagram FD1600 IPS 10 Start up 12 Menu buttons 13 Menu tree structure 14 Floor texts 17 Display fonts 17 Arrows 18 Boot menu 19 Setupmenu...

Page 3: ...uts Outputs 8 Inputs and1 Output Inputs 24 V 0 V Memorycard microSDcard SDand SDHC upto32GB withsoundfiles Speakeroutput 3W8 Size 80 x 61 x 20 mm H x W x D Operating temperature 5 C 40 C Orientations...

Page 4: ...Only trained professionals whoareauthorisedtoworkontheequip ment should install and configurethisproduct This quality product is dedicatedfortheliftindustry Ithasbeen designed and manufactured tobeus...

Page 5: ...oder or a hardwired position unit The FD1600 unit system may contain Floor unit up to 63 floors Car unit up to 2 units System unit none or 1 unit External position unit none or 1 unit It is also possi...

Page 6: ...w SD LED Constantly lit for 2 minutes when SD card is inserted and working After 2 minuter the LED indicator turns off e Green power Constantly lit when powered up All connections have to be in place...

Page 7: ...ut 5 Programmable Input 2 Gray code 2 Input 6 Programmable Input 3 Gray code 3 Input 7 Programmable Input 4 Gray code 4 Input 8 Programmable Gray code signals Gray code is an uncommon way to control f...

Page 8: ...tional FD1600 FD1600v 2 03EN Installation Green Grey Brown Yellow White Grey Orange Black Red Green Yellow Blue Brown In car Unit ID CAR1 Main mode Decimal gray binary Term On Wiringdiagram FD1600 Cab...

Page 9: ...IN 1 IN 2 IN 3 IN 4 IN 8 IN 5 IN 6 IN 7 SPK GND OUT 24V TERM ON OFF SD CARD USB 24V CAN H GND CAN L GND IN 1 IN 2 IN 3 IN 4 IN 8 IN 5 IN 6 IN 7 SPK GND OUT 24V FD1600 FD1600 FD1600 FD1600v 2 03EN Ins...

Page 10: ...ram FD1600 IPS Wiring diagram for car unit and or floor units Grey Orange Black Red Green Yellow Blue Brown In car Unit ID CAR1 Main mode Ext position unit CAN Term Off NOTE If only one display is use...

Page 11: ...D IN 1 IN 2 IN 3 IN 4 IN 8 IN 5 IN 6 IN 7 SPK GND OUT 24V TERM ON OFF SD CARD USB 24V CAN H GND CAN L GND IN 1 IN 2 IN 3 IN 4 IN 8 IN 5 IN 6 IN 7 SPK GND OUT 24V FD1600 FD1600 FD1600 FD1600v 2 03EN In...

Page 12: ...unit i e IPS unit is used also check and set bus termination of these units If no floor trigger is received or generated the display shows the user settable error text This text may also be a symbol...

Page 13: ...usly will Enter configuration mode or Confirm selection Pressing one of the menu buttons at a time will Scroll through the current menu options The menu options will be presented and loops around eith...

Page 14: ...9 SLW CAR reduce 9 STP CAR stop 9 NON None 9 INP Input 9 FLR Floor change 9 ARW Arrow change Arrival sound 9 NON none 9 3T Three tone 9 EN EN81 70 according to regulations WAV Wave Menutree structure...

Page 15: ...defined That is for example if floor count is set to 8 Unit Main Mode is set to Decimal and all inputs are predefined as individual floor generators Each time an input function is selected it is possi...

Page 16: ...the lowest floor ENTER stores encoder position for selected floor The learning process must ALWAYS be in correct sequence 1 2 3 and up to maximum floor position Learning sequence is cancelled by hold...

Page 17: ...system messages System messages are fixed and cannot be changed System messages automatically change depending on the selected language Second part is the user messages and is set up via external pro...

Page 18: ...ED rows 6 dots wide standard style flat spike Style 5 2 LED rows 4 dots wide standard style flat spike Fixed arrows Fixed arrows indicate direction of current travel or intended direction of next trav...

Page 19: ...not all combinations make sense As an example CAR reduce only make sense when using either external position device IPS or an encoder External input only make sense if we also define and use an extern...

Page 20: ...visible if encoder or external position is selected as Main Mode Unit Main mode Encoder Content change 3 Main menu Inputs are only visible if all inputs are not predefined e g if floor count is set t...

Page 21: ...s naming User floor files are always named FLOOR 1 WAV to FLOOR 63 WAV If other names are used the files cannot be found by FD1600 NOTE Space in floor 1 User message files naming User general messages...

Page 22: ...to wiring instructions The termination switch 120 ohm on the FD1600 is activated ON at the beginning and end of the CAN BUS In Main Mode the car unit should be programmed as Ext Position CAN If the F...

Page 23: ...2014 EMC Emission Electromagnetic compatibility EN 12016 2013 EMC Lifts Immunity Electromagnetic compatibility EN 62368 1 2014 AC 2015 LVD Information Technology Equipment EN 50581 2012 RoHS Technica...

Page 24: ...ost safeline no SafeLine Denmark Erhvervsvej 19 2600 Glostrup Denmark Tel 45 44 91 32 72 info dk safeline se SafeLine Headquarters Antennv gen 10 135 48 Tyres Sweden Tel 46 0 8 447 79 32 info safeline...

Reviews: