FD1600 v.2.03 EN
Overview
Inputs
FD1600 can handle different
signals from a controller, these
can be sourced from +24 VDC
or 0 VDC.
Brown
Blue
Yellow
Green
Red
Black
Orange
Grey
Default binary inputs (for 15 floors)
Input 1
Binary 1
Input 5 Programmable
Input 2 Binary 2
Input 6 Programmable
Input 3 Binary 4
Input 7 Programmable
Input 4 Binary 8
Input 8 Programmable
Binary signals
Binary code is a standardized way to control outputs that are used
for floor displays.
Default gray code inputs (for 15 floors)
Input 1 Gray code 1 Input 5 Programmable
Input 2 Gray code 2 Input 6 Programmable
Input 3 Gray code 3 Input 7 Programmable
Input 4 Gray code 4 Input 8 Programmable
Gray code signals
Gray code is an uncommon way to control floor displays. You
only change one input at a time, which minimizes the risk of
error. It is often used on older controllers.
Default decimal inputs (floor 1-8)
Input 1 Floor 1
Input 5 Floor 5
Input 2 Floor 2
Input 6 Floor 6
Input 3 Floor 3
Input 7 Floor 7
Input 4 Floor 4
Input 8 Floor 8
Decimal signals (one-floor-per-pin)
The old way to control floor displays are called decimal or
one-floor-per-pin.
Default decimal inputs (floor 9-16)
Note: two FD1600 units needs to be installed to
address floors 9-16
Input 1 Floor 9
Input 5 Floor 13
Input 2 Floor 10
Input 6 Floor 14
Input 3 Floor 11
Input 7 Floor 15
Input 4 Floor 12
Input 8 Floor 16