TECHNICAL FEATURES 

 

 

The MegaGuard WalkPlus is a portable measuring system that allows analysis 
of charge levels accumulated on the human body according to IEC 61340-4-5 
standard.

 

It's fully portable and doesn't require a PC for data acquisition because all data are 
measured and logged in the internal memory.

 

The operator can perform all necessary operations without any collaborator, and 
while he is walking the instrument is attached only with a single cable to a fixed 
position for the reference to the ground.

 

The graphs of the tests can be displayed on the graphic LCD for a quick evaluation.

 

Then they can be easily exported and analyzed on a PC for a professional 
documentation.

 

A program to manage the tests recorded in the instrument is included in the 
MegaGuard WalkPlus.

 

 

Instrument

 

Range: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±1050V

 

Resolution:   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Volt

 

Accuracy:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5% o ±5V

 

Input resistance: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

14 

 

 

Humidity: 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 to 95%RH

 

. . . . . . . . . . . . . . . . . . . . . . . . . (accuracy: ±2%RH to 25°C, 10%RH~90%RH)

 

Temperature: 

. . . . . . . . . . . . . . . . . . . . . . . . -20°C to +60°C (accuracy: ±1°C )

 

 

Display: . . . . . . . . . . . . . . . . . . . . . . . . . . . graphic LCD 128 x 64 pixel, 68x51mm

 

Power supply: . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 alcaline batteries, LR6 1, 5V

 

Dimensions:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 243x130x60mm (instrument)

 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ø35x130mm (probe)

 

Weight: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 650g (instrument) - 250g (probe)

 

LOW BATTERY = 

     

Blinking 

Auto Shut-off after 10 minutes of inoperativity

 

 

Datalogger

 

In the internal memory of the instrument can be logged till to 10 graphs.

 

Sample rate: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200Hz

 

Max total graphs duration: . . . . . . . . . . . . . . . . . . . . . . . . . . . 2minutes and 30 sec 
Interface: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . USB

 

Summary of Contents for MegaGuard WalkPlus

Page 1: ...SG9265080 INSTRUCTION MANUAL ...

Page 2: ...han authorized repair distributors Do not try to repair the unit by yourself Protecting the environment Separate collection This product must not be disposed of with normal household waste Should you find one day that your product needs replacement or if it is of no further use to you do not dispose of it with household waste Make this product available for separate collection Separate collection ...

Page 3: ... a quick evaluation Then they can be easily exported and analyzed on a PC for a professional documentation A program to manage the tests recorded in the instrument is included in the MegaGuard WalkPlus Instrument Range 1050V Resolution 1 Volt Accuracy 5 o 5V Input resistance 1014 Ω Humidity 1 to95 RH accuracy 2 RH to 25 C 10 RH 90 RH Temperature 20 C to 60 C accuracy 1 C Display graphic LCD 128 x ...

Page 4: ...plied KEYBOARD SETTING To enter the setting mode LEFT To move to the previous menu CURSOR To advance the cursor RIGHT To move to the next menu EXIT To turn on off the instrument and to exit from setting mode and from menu operation START STOP To start stop the measurement To increase the value at the cursor location when you are in setting mode ...

Page 5: ...ne type Close the battery cover OPERATIVE INSTRUCTIONS ON OFF MENU In order to light up MegaGuard WalkPlus press To shut off MegaGuard WalkPlus keep pressed the same key for 1 second The instrument has 6 menu MONITOR ZERO NEW VIEW CLEAR COM Press LEFT to move to the previous menu Press RIGHT to move to the next menu ...

Page 6: ...UCHPLATE internally connected to the two GND inputs The standard IEC 61340 4 5 says that the operator shall take hold the probe and before to start the walking test shall momentarily touch an earth bonding point For this reason in the back of the instrument there is a metal touchplate connected to the two GND inputs that the operator can touch whenever he needs ...

Page 7: ... was made to avoid missing the instrument with measuring active causing battery consumption To deactivate the measuring press START STOP again or EXIT MONITOR Datalogger OFF DATALOGGER MODE If there is free memory space the instrument can log the graph of a new walking test In this menu if the operator press START STOP the instrument shows a pop up window with a short countdown 3 seconds before to...

Page 8: ...P ALARM is no longer active enter the ZERO procedure by pressing 2 times START STOP at the screenshot of this MENU VIEW CLEAR COM If there are graphs logged in the internal memory is possible to see them Press START STOP a pop up window asks you which graph to view Move the cursor pressing CURSOR and select the graph pressing START STOP Press LEFT or RIGHT to scroll the graph Press START STOP agai...

Page 9: ...o advance the cursor and press START STOP to increase the value AUTO range is only available in view mode CLOCK Menu for setting the date and time Press the button CURSOR to advance the cursor and press START STOP to increase the value DISPLAY Menu for setting the contrast of the LCD display 0 to 9 The default contrast is 5 Press the button START STOP to increase the value of contrast C F Menu for...

Page 10: ...ION 1 Connect the MegaGuard WalkPlus to the PC via USB port 2 Enable the MegaGuard WalkPlus port enter in COM menu 3 Run WTManager pull down the Datalogger menu and click on COM port select Select the right port from the availables COM1 COM2 COM3 etc The status of the connection between the MegaGuard WalkPlus and the PC is clearly indicated MegaGuard WalkPlus is connected MegaGuard is not connecte...

Page 11: ...and displaying each of the collected graph WALKING TEST with NOT ESD footwears WALKING TEST with ESD footwears The five highest peaks P1 P5 and the five highest valleys T1 T5 are indicated with their arithmetic means Then the graph can be saved or printed for a professional documentation ...

Reviews: