SF2 Series
Instruction Manual
6
1.4. Safety information
The following points must be observed for a correct and safe use of
the
SAFE
asy
TM
safety device:
•
The stopping system of the machine must be electrically controlled.
•
This control system must be able to instantly stop the dangerous
movement of the machine during all the phases of the working cycle.
•
Mounting and connection of the safety light curtain must only be
carried out by qualified personnel, according to the indications
included in the special sections (
refer to sections 2; 3; 4; 5; 6
).
•
The safety light curtain must be securely placed in a particular
position so that access to the danger zone is not possible without the
interruption of the beams (
see section 2 “Installation mode”
).
•
The personnel operating in the dangerous area must be well trained
and must have adequate knowledge of all the operating procedures
of the safety light curtain.
•
The TEST button must be located outside the protected area
because the operator must check the protected area during all the
Test and Reset operations.