Connect the alarm to a properly fused circuit, maximum over 
protection device rating 15 amps.  

 

 

 

Connect to wiring or circuit that CANNOT be turned off by a switch or 
ground  fault  protector.  Only  use  UL  or  recognized  permanent  wire 
connectors. 

It is acceptable to connect the 85 Series CO / LP gas alarm to 

the  main  disconnect.  The  alarm  will  be  off  along  with  all  other  12  volt 
equipment when the main disconnect is turned to the off position. The RV 
must not be occupied when the main disconnect is in the off position. 

 

Follow these instructions carefully. Failure to follow these instructions can 
damage the unit and void the warranty. Select a wall location at least 4” but 
not more than 20” off the floor. 
 

85-741: 

Disconnect  the  power  supply  being  connected  to.  This 

model requires a 1/2” hole be drilled where mounting. Connect the 
RED (+) power lead to the fused circuit. Connect the BLACK lead 
to Ground (-). Fasten the unit to the wall using the two screw holes 
located  on  the  ends  of  the  case.  Reconnect  the  power  supply.  Wait 
10 minutes for warm up and then test the alarm. 

 

 

85-741  with  optional  trim  ring: 

Disconnect  the  power  supply 

being connected to. This model requires a 1/2” hole be drilled where 
mounting.  Connect  the  RED  (+)  power  lead  to  the  fused  circuit. 
Connect the BLACK lead to Ground (-). Fasten the unit to the wall 
using the two screw holes located on the ends of the case. Reconnect 
the  power  supply.  Wait  10  minutes  for  warm  up  and  then  test  the 
alarm. Use the trim ring to cover existing cutouts.  

NOTE: All connections must be in accordance with the National Electrical 
Code in the Unites Stated and the Canadian Electric Code in Canada.

 

 

TEST PROCEDURE

 

!

 WARNING 

TO  REDUCE  THE  RISK  OF  CARBON  MONOXIDE  POISONING 
OR  PROPANE  GAS  EXPLOSION,  TEST  THIS  ALARM’S 
OPERATION AFTER THE RV HAS BEEN IN STORAGE, BEFORE 
EACH TRIP AND AT LEAST ONCE PER WEEK DURING USE

!

 

WARNING 

WARNING:  THE  TEST  BUTTON  ONLY  TESTS  THE 
ALARM  CIRCUIT  NOT  THE  SENSORS.  YOU  MAY  USE 
PROPANE OR BUTANE GAS TO TEST THE GAS SENSOR. 
Note it may take up to 10 seconds for the alarm to sound. 
TO TEST THE CO SENSOR USE A CAN OF SAFE-T-ALERT 
CO  TEST  GAS  TO  TEST  THE  400  PPM  CALABRATION 
POINT.  DO  NOT  TRY  TO  GENERATE  CO  TO  TEST  THE 
ALARM.

  The TEST/RESET button tests all ELECTRICAL functions of 

the alarm. It does not check the sensor operation. 

The alarm may be tested at any time -The TEST/Mute switch is located on 
the front of the alarm Press and hold the test button for 1 second.  The alarm 
is working properly if the GREEN indicator light changes color to RED and 
the horn beeps 4 times. The Gas LED should also blink Red. 

IMPORTANT

 - 

 If this alarm does not test properly return it immediately 

for repair or replacement. 

 

OPERATION

 

 Each  time  the  unit  is  first  powered  up,  the  CO  sensor  requires  a  ten  (10) 
minute  initial  warm-up  period  to  clean  the  sensor  element  and  achieve 
stabilization. The GREEN LED indicator will flash on and off during the 10 
minute  warm-up  period.  This  unit  cannot  go  into  a  CO  alarm  during  the 
warm-up period.  To test your unit during the warm-up period, press the test 
button.  See  Test  Procedure  in  this  manual.    After  the  warm-up  period,  the 
GREEN power ON indicator should glow continuously

 

If the ON indicator 

light  does  not  light,  see  the  section, 

Trouble-Shooting  Guide

,  in  this 

manual for further information.  

Do not attempt to fix it yourself. 

Gas  Alarm: 

When  you  power  the  alarm,  it  has  a  warm-up  period  of 

approximately  1  minute.  This  unit  cannot  go  into  a  gas  alarm  during  the 
warm-up period.  After 1 minute the alarm can detect explosive gas.  

Simultaneous  CO  and  Gas  Alarms—

  Because  the  risk  of  a  propane  gas 

explosion is generally a more serious danger, your alarm unit gives the gas 
alarm a higher priority during simultaneous alarm condition.

 

If your unit generates alarms for both Gas and CO at the same time, the gas 
LED  will flash red and the beeper will sound.  The CO LED will be a solid 
Red  until  the  CO  is  ventilated  out  of  the  RV,  at  which  time  the  LED  will 
return to the Green operational/safe color.   

Brownout Protection - 

The unit can tolerate short power interruptions and 

brownouts where the circuit voltage drops as low as 1VDC. If the brownout 
lasts too long, the unit will reset and operate as described above. 

 

LOW POWER OPERATION 

This alarm will operate normally down to7 VDC.  Do not operate this alarm 
below 7 VDC.  

 

VISUAL AND AUDIBLE ALARM SIGNALS 

This  SAFE-T-ALERT

TM

 

CO  /  Propane  Gas  Alarm  is  designed  to  be  easy-

to-operate.  The  alarm  has  two  indicator  lights  that  display  a  specific  color 
for  each  monitored  condition.  There  also  is  a  matching  sound  pattern  for 
alarm conditions. 

 

CO ALARM 

The  Red  CO  LED  will  flash  and  the  alarm  will  sound  4  “BEEPS”  then 
silent  for  5  Seconds

.   

These  signals

 

indicate  that  the  CO  level  is  over  35 

ppm.

 IMMEDIATE ACTION IS REQUIRED. 

See 

Procedures To Take 

During An Alarm

. This cycle will continue until the TEST/Mute button on 

the front of alarm is pressed. Ventilate the RV. The RED light will stay ON 
until  the  CO  has  cleared,  or  the  alarm  will  reactivate  in  approximately  6 
minutes  if  the  CO  is  still  present.  DO  NOT  RE-ENTER  THE  RV.  This 
alarm will return to normal operation after the RV s properly ventilated. 

 

PROPANE GAS ALARM 

The  Red  LED  will  Flash  and  the  alarm  will  sound  a  steady  beeping 
whenever  a  dangerous  level  of  propane  gas  is  detected. 

IMMEDIATE 

ACTION  IS  REQUIRED. 

See 

Procedures  Take  During  A  Gas  Alarm

 

The detector will continue to alarm until the Test/Mute switch on the front 
of the alarm is pressed. Ventilate the RV. The RED Gas LED will continue 
to  flash  until  the  gas  has  cleared,  or  the  gas  alarm  will  reactivate  in 
approximately  5  minutes  if  the  gas  is  still  present.  DO  NOT  RE-ENTER 
THE RV. This alarm will return to normal operation after the RV s properly 
ventilated. 

 

MALFUNCTION/SERVICE SIGNAL 

If any malfunction is detected, the 

Gas  LED  will  remain  off  and  the  Operational/CO  LED  will  alternate 
Red/Green  and  the  alarm  will  sound  once  every  15  seconds.  Press  the 
Test/Mute button. If the Test/Mute button does not clear the signals, check 
the battery voltage. I

f the battery voltage is not low and the unit will not 

return to normal operation,

 

immediately remove the alarm and return 