background image

beverages, taken prescription, non-prescription or illegal drugs, may not 
hear the alarm

 

THIS  ALARM IS DESIGNED TO DETECT CARBON MONOXIDE 
AND  PROPANE  GAS.  THE  ALARM  IS  NOT  DESIGNED  TO 
DETECT SMOKE OR FIRE.  

 

 

THIS ALARM MAY NOT ALARM AT LOW CO LEVELS -

 It is not 

designed to measure compliance with the Occupational Safety Health 
Administration (OSHA) commercial or industrial standards. Individuals 
with medical problems may consider using warning devices, which provide 
audible and visual signals for CO concentrations under 30 ppm.  

THIS  ALARM  IS  NOT  A  REPLACEMENT  FOR  INSURANCE.  
Always be sure your RV is fully insured.

 

 

 

Warning:

 Installation of the device should not be used as a 

substitute for proper installation, use, and maintenance of fuel-
burning appliances, including appropriate ventilation and exhaust 
systems.

 

HOW TO PROTECT YOUR FAMILY  

 

CAUTION-  The  SAFE-T-ALERT

TM

  85  SERIES  combination  CO  and 

Gas  Alarm  is  designed  to  protect  individuals  from  the  acute  effects  of 
carbon  monoxide  exposure  and  gas  leaks.  It  will  not  fully  safeguard 
individuals  with  specific  medical  conditions.  If  in  doubt,  consult  a 
medical practitioner. 

To protect your family, you should: 

 

 

INSTALL  THE  ALARM  PROPERLY.

    Carefully  read  and  follow 

ALL the instructions in this manual.  Test your unit every week. Alarms 
that  do  not  work  will  not  alert  you  to  hazardous  levels  of  CO  or 
explosive  gas.  See  the  section, 

Test  Procedure

,  in  this  manual  for 

further information.

 

 

MAKE REGULAR VISUAL INSPECTIONS. 

Check all

 

fuel burning 

equipment including gas water-heaters, kitchen gas stoves, space heaters, 
gas  dryers  and  all  pilot  lights.  Check  the  color  of  the  pilot  flame.    The 
color should be blue. 

 

MAKE  REGULAR  VISUAL  INSPECTIONS  OF  THE  ENGINE 

AND GENERATOR EXHAUST SYSTEMS

. Cracked exhaust systems 

can allow CO to enter the living area. 

 

 

PROFESSIONALLY 

MAINTAIN 

YOUR 

ENGINE 

AND 

GENERATOR.

  Although  gas  engines  and  generators  produce  CO,  a 

poorly tuned engine and generator will produce greater amounts CO. 

 

 

If you smell unusual odors you may have a gas leak, immediately 

call  a  local  propane  gas  supplier  or  fire  department  to  check  for 
possible leaks.

 

 

 

WHERE TO INSTALL   

 

Install  the  85  Series  in  an  area  near  sources  of  a  potential  gas  leaks. 
Some  potential  sources  are  a  furnace,  refrigerator,  stove  or  oven.  If 
potential sources of a gas leak are in separate areas, MTI recommends 
installing a gas alarm in each area. 

 

The Consumer Product Safety Commission recommends installing 
a CO alarm outside the sleeping area.   The 85 Series combination 
CO and gas alarm complies with that recommendation.  

 

INSTALL ALARM 

at least 4 inches but not more than 20 inches off 

the floor.

 

 

 

WHERE NOT TO INSTALL 85 SERIES ALARMS

 

 

 

DO NOT INSTALL 

behind furniture, drapes, in closets or areas that 

will block gas flow to the alarm.  

 

DO  NOT  INSTALL 

within  12  inches  (30cm)  of  opening  windows, 

exterior doors, heating or return vents, or other drafty areas. 

 

 

DO NOT INSTALL 

on an outside wall.

 

 

DO  NOT  INSTALL 

on  a  wall  switch  controlled  by  a  power  line, 

ground fault circuit or to a circuit breaker. 

 

 

NOTE: 

Older  RVs  may  have  little  or  no  insulation  and  therefore  are 

draftier. Carefully consider mounting locations.

 

The following diagrams provide additional alarm installation information:  

 

 

Bedroom

 

Bath

 

Kitchen 

 

Do not install within 12" of 

 

a window that can open

 

Do not install within 

 

12" of a door

 

     Do not install

 

within 12" of vents

 

Do Not install behind

 

drapes or furniture

 

Recommended Alarm Location

 

Kitchen Area

 

Bedroom

 

Living Area

 

Motorhome

 

Travel Trailer

 

Recommended Alarm Location

 

 

 

DO NOT INSTALL

 

Figure

 1 

 

Figure 2

 

       Figure 3

 

 

INSTALLATION INSTRUCTIONS 

!

 WARNING

 

FAILURE  TO  FOLLOW  THESE  INSTRUCTIONS  MAY  RESULT 
IN  A  MALFUNCTION  OR  FAILURE  OF  THE  ALARM  AND  MAY 
VOID THE WARRANTY. 

SHOCK HAZARD: Turn off power before installing.

 

 

Power Supply 12 VDC.  

 

Recommended Wire Size 14 GA. TO 18 GA.

 

 

 