1  General description. ........................................................................................................ 3 
2  Safety conditions ............................................................................................................. 3 
3  Connector and control elements, .................................................................................... 4 
4  Designation of displayed messages. ................................................................................. 5 
5  Button features. ............................................................................................................... 6 
6  Group DMX address settings. .......................................................................................... 6 
7  Individual DMX address settings. ..................................................................................... 7 
8  Color settings mode. ........................................................................................................ 8 
9  No DMX signal response. ............................................................................................... 10 

9.1  Description of programs. ......................................................................................... 11 

10  Master / Slave function. ............................................................................................. 12 
11  White balance. ............................................................................................................ 13 
12  Limiting the output power. ......................................................................................... 14 
13  Smooth. ...................................................................................................................... 14 
14  Light control frequency. .............................................................................................. 15 
15  Screen saving (screen blanking). ................................................................................. 16 
16  Default settings and device errors. ............................................................................. 16 

16.1 Restore default settings. .......................................................................................... 16 
16.2 Error message. ......................................................................................................... 17 

17  Display function. ......................................................................................................... 17 
18  DMX signal connecting ............................................................................................... 18 
19  RDM – available parameters ....................................................................................... 18 
20  Programming. ............................................................................................................. 21 
21  Connection scheme. ................................................................................................... 22 
22  Dimensions. ................................................................................................................ 23 
23  Technical data. ............................................................................................................ 24 

 

 

 

 

Summary of Contents for F6324265

Page 1: ...he product and our company Carefully read the instructions for use and become familiar with the equipment before using it for the first time All work with this equipment should only be carried out in...

Page 2: ...dress settings 6 7 Individual DMX address settings 7 8 Color settings mode 8 9 No DMX signal response 10 9 1 Description of programs 11 10 Master Slave function 12 11 White balance 13 12 Limiting the...

Page 3: ...manufacturer 3b each color RGB can be set separately 3bd each color RGB can be set separately and dimmer dimming all outputs 3bS each color RGB can be set separately frequency strobo and fill factor H...

Page 4: ...supply can only be made with a conductor of minimum cross section area of 2 5mm2 and DMX signal with shielded conductor 5 All repairs and connections of outputs or DMX signal can only be made with cu...

Page 5: ...ED RGB DRIVER F6324265 Property of SAFERAIN S L www saferain com Safe Rain S L info saferain com Fabricantes de equipamiento para fuentes ornamentales y riego de jardines 5 4 Designation of displayed...

Page 6: ...he same MENU level or decreases the parameter s value next scrolls to the next feature on the same MENU level or increases the parameter s value enter enters the next MENU level and confirms changes m...

Page 7: ...3 Push the enter button to confirm choose ENTER ENTER ENTER 7 Individual DMX address settings The F6324265 module has an option that allows for changing individual settings It enables assigning any DM...

Page 8: ...nnels Shutter 6 channel mode allows to set each colors separately on channels 1 3 R G B and has an additional Shutter function Channels 4 and 5 are responsible for frequency of which channel 4 is resp...

Page 9: ...D CHANNEL 2 GREEN CHANNEL 3 BLUE CHANNEL 4 MODE CHANNEL 5 SPEED CHANNEL 6 FADE CHANNEL 7 BRIGHTNESS 0 7 Program 1 x x x 8 15 Program 2 x x x 16 23 Program 3 x x x 24 31 Program 4 x x x 32 39 Program 5...

Page 10: ...nnecting an external controller Once it is activated if there is no DMX signal the module will realize a desired function independently Reconnecting the DMX signal will automatically break the realize...

Page 11: ...hannel R G B in programs from 1 up 18 P01 P18 The value 255 corresponds to the maximum lightness level on a given channel 127 50 of power level 0 full channel blanking P01 P02 P03 P04 P05 P06 P07 P08...

Page 12: ...rolled from any desktop or controller running in this standard Moreover it is equipped with a programmable function of response to no DMX signal noS With 18 built in default programs it is possible to...

Page 13: ...the RGB series LEDs This may be a result of using diodes with different technical parameters For this reason the F6324265 module is equipped with a white balance function This option allows for choosi...

Page 14: ...r the output power limitation value for the red channel 0 100 bLG the output power limitation value for the green channel 0 100 bLb the output power limitation value for the blue channel 0 100 bCn tur...

Page 15: ...n allows for setting the basic control frequency for the LEDs This function is extremely useful in applications for the television industry By applying the flicker free technology it is possible to av...

Page 16: ...or menu items are displayed incorrectly this may indicate that a saving inmemory error has occurred In such a case try to restore the device to its default settings before sending the F6324265 to the...

Page 17: ...ror In this situation select the enter key The device will reload the default configuration and upload it to the memory If after this operation the Err message remains on the screen the memory is perm...

Page 18: ...ches on DMX control cable That means that DMX line from the signal source must be connected to DMX IN pins of F6324265 and later directly from DMX OUT pins to the next device in DMX chain If the F6324...

Page 19: ...nformation about device status DEVICE_MODEL_ DESCRIPTION 0x0080 device description e g name MANUFACTURER_LABEL 0x0081 manufacturer description e g name DEVICE_LABEL 0x0082 additional device descriptio...

Page 20: ...OFF 0x8022 settings of screensaver display backlight in F6324265 PROGRAM_SPEED 0x8025 programs playback speed settings playing next steps of program PROGRAM_FADE 0x8026 settings of smooth transition...

Page 21: ...21 20 Programming...

Page 22: ...22 21 Connection scheme Note The driver F6324265 is common anode type device It is possible to connect lamps with 4 wires cable with a common only...

Page 23: ...warm and cold white LEDs strips for Dynamic White mode With such a connection of strips in dW control mode the value 0 on the color temperature channel corresponds to warm white color and value 255 c...

Page 24: ...nsumption 18A power consumption without load 30mA for 12V DC 40mA for 24V DC output channel number 3 control accuracy 16 bit programmable scenes 1 built in programs 18 outputs current capacity 6A chan...

Page 25: ...25...

Reviews: