pushed.
The welding time is set with the spot time control and will
be constant independently from the operation of the
Trigger.
To set the spot time, user has to push SEL button until
text SPT appears on the left display: turning now the main
know is possible to set SPT time from 0 to 100s
Bi-Level (Set/A2) Trigger sequence
Enter Menu GTAW and enable BILV option.
When enabled, the bi-level tig function replaces the 4S
trigger sequence.
To select Bi-Level sequence:
Output
Visualization
Press several times until the LED above lights up
When bi-level is selected in left display without any
welding operation you can see the text:
B-V.V
V.V indicates the output voltage [1.0-1.5V] when not
welding.
With this sequence the arc is started as in the 4S
sequence, this means that steps 1 and 2 are the same.
3. Quickly press and release the TIG torch trigger. The
machine will switch the current level from Set to A2
(background current). Each time this trigger action is
repeated the current level will switch between the two
levels.
3.A. Press and hold the TIG torch trigger when the
main part of the weld is complete. The machine
will now decrease the output current at a
controlled rate, or downslope time, until the Crater
current is reached. This Crater current can be
maintained as long as necessary.
To set the A2 level, user has to push SEL button until text
A2 appears on the left display: turning now the main know
is possible to set A2 in percentage of the setting current.
NOTE: The Restart option and the Pulse function are not
available for Bi-Level Trigger sequence
LIFT TIG ON sequence
When lift tig process is selected, it is possible to performe
welding operation without the use of a trigger.
To select ON sequence:
Output
Visualization
Press several times until the LED above lights up
When the sequence is selected it is possible to start a
weld with the lift method without pushing trigger.
To end the weld it is necessary to break the arc.
The parameter Starting current, Final slope and finishing
current are ignored.
Summary of Contents for PRESTOTIG 200 AC/DC
Page 2: ......
Page 313: ...I 12 05 1 2 3 5 5 WEEE 26 26 REACh 26 26 26 27...
Page 315: ...2 01 11 A IEC 61000 3 11 IEC 61000 3 12 83 0 6 A...
Page 316: ...3 01 11 Lincoln Electric CE CE 2006 25 EC EN 12198 2 15 EN169...
Page 317: ...4 HF TIG GTAW TIG GTAW 85 8...
Page 323: ...10 4 5 A 9 1 2 1 M 1 SAVE 2 M 2 RECALL 3 M 3 MEM SET 3 3 3 MEM SAVE...
Page 326: ...13 5 2 2 2 TIG 1 TIG 25 LIFT 2 TIG TIG TIG 2 2 2 GTAW 2RST 2 1...
Page 329: ...16 2 SEL A2 2 TIG LIFT TIG ON TIG ON...
Page 436: ......