"Hi"
High level reset
Beeps are made to reset the high level by
pressing forward/reverse selector switch
④ while completely depressing knee
control panel ⑧.
"Lo"
Low level reset
Beeps are made to reset the low level by
pressing forward/reverse selector switch ④,
without depressing knee control panel ⑧.
"rc"
Recovery
The magnet sensor reset mode is
returned to the main mode by pushing the
forward/reverse selecto switch.
Reset mode
Function
How to reset
9.3 Magnet sensor reset mode
Beeps are made 2 seconds after turning on the power switch while pressing both
hand/foot selector switch ③ and forward/reverse selector switch ④ at a time, which mean
the reset to magnet sensor mode. BY turning speed control knob ②, it is possible to reset
the mode to
“Hi,”
“Lo”and
“rc”modes.
CAUTION
For safety, the above conditions have been already set when shipped and, therefore, do
not change them.
9.4
Specifications
9.4.1 Control unit
- Model : SDE-S60/L60
- Power supply : AC200~240V, 50/60Hz or AC100~120V, 50/60Hz
- Weight : 2.9㎏
- Dimension : 94㎜(W) x 268㎜(D) x 228㎜(H)
9.4.2 Motor handpiece
- Model : SDE-BH60
- Speed : 1,000~50,000RPM
- Weight : 230g(not including the motor cord)
- Dimension : L159 x ф27
- Cord length : 1.4m
9.4.3 Foot pedal
- Model : FS60
- Weight : 384g
- Cord length : 1.8m
9.4.4 Control unit stand
- Weight : 152g
- Dimension : 122㎜(W) x 268㎜(D) x 30㎜(H)
9.4.5 Motor handpiece stand
- Weight : 68g
- Dimension : 60㎜(W) x 110㎜(D) x 45㎜(H)
Summary of Contents for Marathon Multi600
Page 1: ...USER S MANUAL 使 用 說 明 書 使 用 說 明 書 사 용 설 명 서 ...
Page 2: ......
Page 16: ...CHN ...
Page 31: ......
Page 32: ......
Page 33: ......
Page 34: ......
Page 39: ......