Sael RRF Installation And Operating Manual Download Page 4

 

 

PRODUCT DESCRIPTION 

The  transceiver  RRF  is  an  interface  converter  from  Rs232-Rs422/485-USB  to  Radio  Frequency  868  MHz, 
with 3 modes of operation: DIRECT, SINGLE and MULTI, selectable via software through a special configu-
rator. The data format is fixed for all modes: 38400, N, 8, 1. 

RRF installation and operating manual 

TRF 

 
 

INDICATOR 

RRF

 

RS232 

RS485 

Application 2 (SINGLE): acquisition of a single weight from a TRF through an indicator 

 
 

UNIT B 

RRF

 

RS232 
RS485 

Application 1 (DIRECT): wireless interface between two units  

RRF

 

 

UNIT A 

USB 

RS232 
RS485 

USB 

Pag. 4 

Used in pairs, simulates a serial connection using a wireless connection. (Application 1). 

DIRECT MODE

 

MULTI MODE

 

This mode is used to capture the weight from multiple weight transmitters, model TRF (up to 15): in this case 
the RRF transceiver communicates with the TRF and made available on the serial port (or USB) a string with 
all the weight obtained. (Applications 4, 5 and 6).  
The RF communication frequency is 868MHz, with power up to 10mW, with 7 operation channels selectable 
from dip-switch for installations where are present multiple RF devices. 
The power is at 5Vdc and can be supplied via the USB port when the transceiver is connected to a PC, oth-
erwise can be provided by the weight indicator we produce. 
The  RRF  has  programmable  operating  parameters,  such  as  RF  Power  and  the  Communication  Protocol. 
The  programming  of  the  operating  parameters  is  made  through  a  PC  application  that  allows  you  to  easily 
configure and just in few steps the system used (TRF and RRF). 

It is used to interface with the weight transmitter for load cell, model TRF, in the manners explained below. In 
particular it can be used to gain the weight from a single transmitter through the communication port Rs232, 
Rs485 or USB. (Applications 2 e 3). 

SINGLE MODE

 

TRF 

RRF 

USB 

PC 

Application 3 (SINGLE): acquisition of a single weight from a TRF through a PC 

Summary of Contents for RRF

Page 1: ...RF TRANSCEIVER RRF INSTALLATION AND OPERATING MANUAL SOFTWARE CODE PRRF04 VERSION Rev 0 0...

Page 2: ...Page 8 RS232 SERIAL CONNECTION Page 8 RS422 RS485 SERIAL CONNECTION Page 9 USB CONNECTION Page 9 RF CHANNEL SELECTION Page 10 SELECTING THE NUMBER OF TRF IN THE NETWORK MULTI Page 10 INSTRUMENT CONFIG...

Page 3: ...ions For each anomaly contact your nearest Service Centre Any attempt to disassemble the instrument or any modification of the instrument not expressly approved will void the warranty and will relieve...

Page 4: ...the serial port or USB a string with all the weight obtained Applications 4 5 and 6 The RF communication frequency is 868MHz with power up to 10mW with 7 operation channels selectable from dip switch...

Page 5: ...ugh an indicator RRF TRF TRF TRF 1 2 N USB PC Application 5 MULTI acquisition of the weight from N TRF transmitters through a PC RRF installation and operating manual Pag 5 INSTRUMENT 1 RRF RS485 TRF...

Page 6: ...xcluding antenna and connector Enclosure Cast aluminium Protection degree IP65 Connection Screw terminals pitch 5 08 mm cable gland SERIAL INTERFACE Rs232 Communication parameters 9600 19200 38400 N 8...

Page 7: ...ddition INSTRUMENT INSTALLATION The following procedures must be performed by qualified personnel All connection must be performed with instrument turned off The instrument is secured by 2 screws inse...

Page 8: ...cy is sensitive to vibration Fasten the instrument and use the dumpers RS232 SERIAL CONNECTION To make the serial connection use a shielded cable making sure to ground the shield at one of the two end...

Page 9: ...s for example outputs connected to con tactors or power cables but must follow his own path USB CONNECTION The USB cable is connected via the terminal block inside the instrument In the version with U...

Page 10: ...y application 4 5 and 6 must be select the number of TRF transmitters connected via radio In mode SINGLE and DIRECT this selection is not considered The selection of the number of TRF is made through...

Page 11: ...15mW to 10 mW The programming of these parameters is performed using the PC application PWIN38 that allows through a wizard to configure the RF system in few steps The PC is connected via USB port use...

Page 12: ...t loader on waiting to receive file LED blinks continuously Function of the boot loader in progress FIRMWARE BOOT LOADER The instrument has the boot loader function for firmware update This can be don...

Page 13: ...transmitted 8 characters BATT ASCII string of voltage battery 2 characters expressed in tenths of Volts ETX end of text text end character ASCII value 0x03 CHKSUM two character checksum of string dat...

Page 14: ...on Verify the installation by referring to this manual Hardware failure Use the diagnostic LED to indicate the fault detected The receiver does not receive the correct string Incorrect communication p...