English
66
10
Open the service door.
1010101010
Remove the brew group by pulling it by the handle and
pressing the «PRESS» button. The brew group must be
washed with lukewarm water only. Do not use any
detergent.
1010101010
Wash the brew group with lukewarm water; carefully
wash the upper filter. Before placing the brew group in
its seat, ensure that there is no water left in the
brewing chamber.
10101010
Make sure that the brew group is in the off position.
The two reference marks must match.
10101010
If they do not match, proceed as described below:
10
Ensure that the lever is in contact with the brew group
base.
10101010
Make sure that the hook which locks the brew group is
in the correct position. firmly press the "PRESS"
button to check its position.
10101010
Insert the brew group into its seat again until it locks
into place WITHOUT pressing the "PRESS" button.
1010
Close the service door.
1010
Ensure that the brew group
is completely dry before
putting it back into the
machine.
10